Agilent TechnologiesAgilent TS-5000 Series Automotive Functional Test SystemE6198B Switch/Load Unit Software Manual
2-2 E6198B Switch/Load Unit Software Manual2 Installing The Driver How To Install The DriverOnce CD has been inserted, there are two separate installa
Installing The Driver 2E6198B Switch/Load Unit Software Manual 2-3 Step 2: Click Next to start InstallShield WizardFigure 2-2 Bitwise System Quick
2-4 E6198B Switch/Load Unit Software Manual2 Installing The Driver Step 4: Read the following ReadMe Information then click NextFigure 2-4 Bitwise S
Installing The Driver 2E6198B Switch/Load Unit Software Manual 2-5 Step 6: Choose installation folder path then click NextFigure 2-6 Bitwise Syste
2-6 E6198B Switch/Load Unit Software Manual2 Installing The Driver Step 8: Installation is ready to start, click Install to proceed.Figure 2-8 Bitwi
Installing The Driver 2E6198B Switch/Load Unit Software Manual 2-7 Step 2: Choose install folder path then click NextFigure 2-10 SLU Plus Installat
2-8 E6198B Switch/Load Unit Software Manual2 Installing The Driver Step 4: Click Finish to exit the installation procedureFigure 2-12 SLU Plus Instal
3-1Agilent TS-5000 Series Automotive Functional Test SystemE6198B Switch/Load Unit Software Manual Agilent Technologies3Programming With TestExec SLTh
3-2 E6198B Switch/Load Unit Software Manual3 Programming With TestExec SL Procedure of Programming TestExec SL Specific HandlerStart With System Confi
Programming With TestExec SL 3E6198B Switch/Load Unit Software Manual 3-3 Configuring an Agilent E6198B Switch/Load UnitFigure 3-14 The parameters
Notices© Agilent Technologies, Inc. 2007No part of this manual may be reproduced in any form or by any means (including electronic storage and retriev
3-4 E6198B Switch/Load Unit Software Manual3 Programming With TestExec SL Example of a Switch/Load Unit Parameter Block Data ValuesTab le 3- 1 Typica
Programming With TestExec SL 3E6198B Switch/Load Unit Software Manual 3-5 Example of a Switch/Load Unit Wiring Configuration ValuesTab le 3 -2 Typi
3-6 E6198B Switch/Load Unit Software Manual3 Programming With TestExec SL Example Of Using TxSL To Call SLUHandlerTxSL 6.1 or higher version should be
Programming With TestExec SL 3E6198B Switch/Load Unit Software Manual 3-7 Step 3: Edit the arguments by clicking on “Edit Arguments” button. Select
3-8 E6198B Switch/Load Unit Software Manual3 Programming With TestExec SL Step 5: Add Dynamic Link Library directory by clicking Options>System Opt
Programming With TestExec SL 3E6198B Switch/Load Unit Software Manual 3-9 After all actions is defined and saved. You can create a testplan and use
3-10 E6198B Switch/Load Unit Software Manual3 Programming With TestExec SL Following action is SetLoadSwitch. This action actuates the load contact of
Programming With TestExec SL 3E6198B Switch/Load Unit Software Manual 3-11 NOTEAgilent TS-5000 Application Software is not included on Agilent E6198
3-12 E6198B Switch/Load Unit Software Manual3 Programming With TestExec SL Auto Detection By System Configuration Editor(SCE)This editor can auto-dete
Programming With TestExec SL 3E6198B Switch/Load Unit Software Manual 3-13 Click on switching path button on Parameters for “Switching” to select wh
E6198B Switch/Load Unit Software Manual iiiContents1 IntroductionWhat’s in This Guide? 1- 2Switch Load Unit Software Overview 1- 32 Installing
3-14 E6198B Switch/Load Unit Software Manual3 Programming With TestExec SL THIS PAGE IS INTENTIONALLY LEFT BLANK.
4-1Agilent TS-5000 Series Automotive Functional Test SystemE6198B Switch/Load Unit Software Manual Agilent Technologies4Programming With Generic Appli
4-2 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler Available Function CallsFollowing sub chapters give an overv
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-3 Valid Ranges For Load, Power And Sense Channels Vs. Load C
4-4 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler General RoutinesThis chapter lists the implemented routines
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-5 Return value. Call returns 0 in case of success.RemarksThi
4-6 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler Activate Load Card RelaysSetLoadSwitchvoid SetLoadSwitch (lo
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-7 Return value. Call returns 0 in case of success.RemarksThi
4-8 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler Valid range: 1-21channelSee Table 4-4, “Valid Range For The
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-9 RemarksThis function actuates the sense multiplexer relays
iv E6198B Switch/Load Unit Software ManualTHIS PAGE IS INTENTIONALLY LEFT BLANK.
4-10 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler Digital IO and DAC ControlGetDigitalInputvoid GetDigitalInp
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-11 Valid range: 0-7digitalOutReturn value: 0-255statusReturn
4-12 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler Return value. Call returns 0 in case of success.RemarksThis
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-13 Return value. Call returns 0 in case of success.RemarksTh
4-14 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler Error CodesThe Error Codes representing the feedback messag
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-15 Example Of Using Generic HandlerLike all instruments, the
4-16 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler int e6198b_6176_openLoadSwitch(long boxNr,long slotNr, long
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-17 }int e6198b_6178_openLoadSwitch(long boxNr,long slotNr, l
4-18 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler return slu_status;}CloseSlu() function closes all previousl
Programming With Generic Application Handler 4E6198B Switch/Load Unit Software Manual 4-19 }int main(){ long return;e6198b_openCurrentSense(0, 1,&am
1-1Agilent TS-5000 Series Automotive Functional Test SystemE6198B Switch/Load Unit Software Manual Agilent Technologies1IntroductionThe Agilent Switch
4-20 E6198B Switch/Load Unit Software Manual4 Programming With Generic Application Handler THIS PAGE IS INTENTIONALLY LEFT BLANK.
G-1Agilent TS-5000 Series Automotive Functional Test SystemE6198B Switch/Load Unit Software Manual Agilent TechnologiesGlossary Of Terms
G-2 E6198B Switch/Load Unit Software ManualG Glossary Of Terms •AliasesAlternate names for nodes, wires, or other aliases. The names are descriptive i
1-2 E6198B Switch/Load Unit Software Manual1 Introduction What’s in This Guide?This chapter provides an overview of new driver. Subsequent chapters in
Introduction 1E6198B Switch/Load Unit Software Manual 1-3 Switch Load Unit Software OverviewSwitching is useful in functional testing of complex uni
1-4 E6198B Switch/Load Unit Software Manual1 Introduction THIS PAGE IS INTENTIONALLY LEFT BLANK.
2-1Agilent TS-5000 Series Automotive Functional Test SystemE6198B Switch/Load Unit Software Manual Agilent Technologies2Installing The DriverThe CD wi
Komentáře k této Příručce