Agilent Technologies 8922M Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Sítě Agilent Technologies 8922M. Agilent Technologies 8922M User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 94
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP/Agilent 8922 GSM HSCSD Test System
Option #K09
Supplementary
User’s Guide
Systems Covered
HP/Agilent 8922 P Multi-Band Test System
Manufacturing Part Number: 08922-90218
© Copyright February 1999 Agilent Technologies
Zobrazit stránku 0
1 2 3 4 5 6 ... 93 94

Shrnutí obsahu

Strany 1 - Option #K09

HP/Agilent 8922 GSM HSCSD Test SystemOption #K09SupplementaryUser’s GuideSystems CoveredHP/Agilent 8922 P Multi-Band Test SystemManufacturing Part Num

Strany 2 - Limitation of Warranty

xAbout this GuideOverviewThis User’s Guide is a supplement to the manuals currently suppliedwith the HP/Agilent 8922 GSM Test Sets. The information co

Strany 3 - Certification

Contentsxi1. Understanding the HP/Agilent 8922 GSM HSCSD Test SystemGetting an overview of the HP/Agilent 8922 GSM HSCSD Test System.2Features . . . .

Strany 4 - Restricted Rights Legend

xiiContentsHSCSD screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271. Master downlink amplitude . .

Strany 5 - Information

ContentsxiiiHSCSd:MASTer:DOWNlink:AMPLitude . . . . . . . . . . . . . . . . . . . . . . .50HSCSd:MASTer:TCH:TLEVel . . . . . . . . . . . . . . . . . .

Strany 6 - Safety Information

xivContentsA. Upgrading the HOP Controller ROM and FirmwareUpgrading the Hop Controller ROM. . . . . . . . . . . . . . . . . . . . . . . . . . . . 76U

Strany 7

11 Understanding the HP/Agilent8922 GSM HSCSD Test SystemThis chapter provides an overview of the HP/Agilent 8922 GSM HSCSDTest System.

Strany 8 - Safety Symbols

2 Chapter1Understanding the HP/Agilent 8922 GSM HSCSD Test SystemGetting an overview of the HP/Agilent 8922 GSM HSCSD Test SystemGetting an overview o

Strany 9

Chapter 1 3Understanding the HP/Agilent 8922 GSM HSCSD Test SystemGetting an overview of the HP/Agilent 8922 GSM HSCSD Test SystemThe HP/Agilent 8922

Strany 10 - About this Guide

4 Chapter1Understanding the HP/Agilent 8922 GSM HSCSD Test SystemFeaturesFeaturesThe HP/Agilent 8922 GSM HSCSD Test System supports the followingfeatu

Strany 11 - Contents

52 Setting up the HP/Agilent 8922GSM HSCSD Test SystemThis chapter describes how to connect and set up the HP/Agilent 8922GSM HSCSD Test System.

Strany 12

iiWarrantyThis Agilent Technologies instrument product is warranted againstdefects in material and workmanship for a period of one year from dateof sh

Strany 13

6 Chapter2Setting up the HP/Agilent 8922 GSM HSCSD Test SystemBefore you startBefore you startWARNING The HP/Agilent 8922 is a Safety Class 1 product

Strany 14

Chapter 2 7Setting up the HP/Agilent 8922 GSM HSCSD Test SystemChecking the HP/Agilent 8922 Requirements for HSCSDChecking the HP/Agilent 8922 Require

Strany 15 - 8922 GSM HSCSD Test System

8 Chapter2Setting up the HP/Agilent 8922 GSM HSCSD Test SystemMaking the front panel connectionsMaking the front panel connectionsBefore you connect t

Strany 16 - GSM HSCSD Test System

Chapter 2 9Setting up the HP/Agilent 8922 GSM HSCSD Test SystemMaking the rear panel connectionsMaking the rear panel connectionsBefore connecting the

Strany 17

10 Chapter2Setting up the HP/Agilent 8922 GSM HSCSD Test SystemMaking the rear panel connectionsFigure 2-2 Rear panel connectionsGPIB cableSystem bus

Strany 18 - Features

Chapter 2 11Setting up the HP/Agilent 8922 GSM HSCSD Test SystemEnabling the HSCSD functionalityEnabling the HSCSD functionalityYou must enable the HS

Strany 19

12 Chapter2Setting up the HP/Agilent 8922 GSM HSCSD Test SystemEnabling the HSCSD functionalityFigure 2-4 Tests screenStep 4. Set Location to CARD.Ste

Strany 20 - Before you start

Chapter 2 13Setting up the HP/Agilent 8922 GSM HSCSD Test SystemEnabling the HSCSD functionalityFigure 2-5 Config screenTo disable HSCSDfunctionalityTo

Strany 21

14 Chapter2Setting up the HP/Agilent 8922 GSM HSCSD Test SystemCalibrating the overall systemCalibrating the overall systemThere is an RF loss through

Strany 22 - Master Slave

153 Manual operationThis chapter describes the basic procedures required to manuallyoperate the HP/Agilent 8922 GSM HSCSD Test System. For more detail

Strany 23

iiiLimitation of Remedies and LiabilityTHE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE ANDEXCLUSIVE REMEDIES. AGILENT TECHNOLOGIES SHALL NOTBE LIABLE F

Strany 24 - 10 Chapter2

16 Chapter3Manual operationConfiguring the systemConfiguring the systemTo configure the HP/Agilent 8922 GSM HSCSD Test System for manualoperation, procee

Strany 25

Chapter 3 17Manual operationConfiguring the systemThe slave unit’s GPIB address is now automatically set to 15 (seen in theIO Config screen) which is t

Strany 26

18 Chapter3Manual operationEstablishing a callEstablishing a callYou establish a call in the same way as for a speech call.Step 1. Ensure that the mas

Strany 27 - HSCSD MASTER

Chapter 3 19Manual operationMaking measurementsMaking measurementsOnce a call is established, you can make measurements as before—seethe HP/Agilent 89

Strany 28

20 Chapter3Manual operationChanging power levels, timeslot and channelsChanging power levels, timeslot and channelsYou can change downlink and uplink

Strany 29 - 3 Manual operation

Chapter 3 21Manual operationEnding a callEnding a callEnding a call is the same procedure as that used for a standard HP/Agilent 8922 Test System, how

Strany 30 - Configuring the system

22 Chapter3Manual operationEnding a call

Strany 31

234 ScreensThis chapter describes the screens that are part of the HP/Agilent 8922GSM HSCSD Test System. For more details on all other screens, refer

Strany 32 - Establishing a call

24 Chapter4ScreensConfig screenConfig screenFigure 4-1 Config screen1. Instrument typeHSCSD Master and HSCSD Slave indicate that the HP/Agilent 8922 ispa

Strany 33 - Making measurements

Chapter 4 25ScreensConfig screen• set the slave GPIB address to match the address of the slave unit• make sure that the addresses of the slave and mast

Strany 34

ivtraceable to the United States National Bureau of Standards andTechnology, to the extent allowed by the Bureau’s calibration facility, andto the cal

Strany 35 - Ending a call

26 Chapter4ScreensConfig screen2. Slave addressThe Slave address field appears only if you have selected HSCSDMaster as the instrument type and is the a

Strany 36 - Manual operation

Chapter 4 27ScreensHSCSD screenHSCSD screenFigure 4-2 HSCSD Control screen1. Master downlink amplitudeThe Master downlink amplitude field shows the dow

Strany 37 - 4 Screens

28 Chapter4ScreensHSCSD screenadding an offset (see page 28) to this value.NOTE The default is reset when you select the instrument type (see page 2

Strany 38 - Config screen

Chapter 4 29ScreensHSCSD screenThe Master Channel field shows the ARFCN of the TCH. There is onlyone ARFCN, as HSCSD systems place all timeslots on the

Strany 39

30 Chapter4ScreensHSCSD screen4. Master timeslotThe Master timeslot field indicates which timeslot is used for themaster TCH. As the slave TCH is alway

Strany 40 - 2. Slave address

Chapter 4 31ScreensHSCSD screen6. Call TypeThe Call Type field determines which type of HSCSD call the HP/Agilent 8922 establishes the next time a call

Strany 41 - HSCSD screen

32 Chapter4ScreensHSCSD screen7. Data rateThe Data rate field determines the data rate associated with theHSCSD 2x2 call. Selecting '9.6' set

Strany 42 - 3. Master channel

Chapter 4 33ScreensHSCSD screen9. Master Tx levelOn a master unit, the Master Tx level field requests a new transmitlevel for the uplink master TCH. On

Strany 43

34 Chapter4ScreensHSCSD screen10. Master input levelThe Master Input level field sets the expected power of the masteruplink TCH. You can set the level

Strany 44 - 5. Slave timeslot

Chapter 4 35ScreensHSCSD screen11. Master modeThe Master mode field either makes or breaks the link between theMaster Tx level (see page 33) and the Ma

Strany 45 - 6. Call Type

v"restricted computer software" as defined in FAR 52.227-19 (June 1987)or any equivalent agency regulation or contract clause. Use, duplicati

Strany 46 - 8. Measure

36 Chapter4ScreensHSCSD screenOn both units, if the instrument is operating in standard mode, settingthis field changes the slave control field (see pag

Strany 47 - 9. Master Tx level

Chapter 4 37ScreensHSCSD screencontrol type is MS Tx Lev, then the instrument returns an error (Can’tchange setting while MS TX Lev mode is selected.)

Strany 48 - 10. Master input level

38 Chapter4ScreensHSCSD screen15. Mobile reportsThe Mobile Reports are the same uplink SACCH reports as appear onthe Cell Status screen. The reports a

Strany 49 - 12. Slave Tx level

Chapter 4 39ScreensFast BER ScreenFast BER ScreenOne extra field, labelled Loopback, appears in the Fast Bit Error screen,when the HP/Agilent 8922 is i

Strany 50 - 13. Slave input level

40 Chapter4ScreensFast BER ScreenLoopbackThe Loopback field selects which downlink slot is looped back on themaster uplink.Type toggleChoices “Master”,

Strany 51 - 14. Slave control

415 Remote operationThis chapter explains how to operate the HP/Agilent 8922 GSM HSCSDTest Systemover the GPIB. The new GPIB commands for the HP/Agile

Strany 52 - 17. To Screen menu

42 Chapter5Remote operationIntroductionIntroductionThe general principle of operation is that the settings on the slave unitare relative to the settin

Strany 53 - Fast BER Screen

Chapter 5 43Remote operationConfigure Subsystem GPIB CommandsConfigure Subsystem GPIB CommandsFigure 5-1 Configure Instrument Type comand syntaxCONFigure

Strany 54 - Loopback

44 Chapter5Remote operationDisplay Subsystem GPIB CommandsDisplay Subsystem GPIB CommandsFigure 5-2 Display Screen command syntaxDISPlay:SCReen HSCSDD

Strany 55 - 5 Remote operation

Chapter 5 45Remote operationHSCSD Subsystem GPIB CommandsHSCSD Subsystem GPIB Commands

Strany 56 - Introduction

viSound EmissionManufacturer’s DeclarationThis statement is provided to comply with the requirements of theGerman Sound Emission Directive, from 18 Ja

Strany 57 - CONFigure:INSTrument[:TYPE]

46 Chapter5Remote operationHSCSD Subsystem GPIB CommandsFigure 5-3 HSCSD command syntax (master unit)HSCSdTCHDOWNlinkMEASureSTATusTSLotARFCnARFCn?AMPL

Strany 58 - DISPlay:SCReen HSCSD

Chapter 5 47Remote operationHSCSD Subsystem GPIB CommandsFigure 5-4 HSCSD command syntax (slave unit)SLAVeTCHSTATusOFFSetrealUPlinkAMPLitudeAMPLitude?

Strany 59 - HSCSD Subsystem GPIB Commands

48 Chapter5Remote operationHSCSD Subsystem GPIB CommandsHSCSd:MASTer:TCH:ARFCnDescription Setting this during a call forces a channel assignment to th

Strany 60 - Remote operation

Chapter 5 49Remote operationHSCSD Subsystem GPIB CommandsHSCSd:MASTer:STATus:TCH:TSLotDescription Setting this during a call changes the master timesl

Strany 61 - Chapter 5 47

50 Chapter5Remote operationHSCSD Subsystem GPIB CommandsHSCSd:MASTer:DOWNlink:AMPLitudeDescription This sets the downlink amplitude of the master TCH.

Strany 62 - HSCSd:MASTer:TCH:ARFCn

Chapter 5 51Remote operationHSCSD Subsystem GPIB CommandsHSCSd:MASTer:TCH:TLEVelDescription During a call, this sets the Tx level of the master TCH.Wh

Strany 63 - HSCSd:MASTer:STATus:TCH:TSLot

52 Chapter5Remote operationHSCSD Subsystem GPIB CommandsHSCSd:MASTer:UPLink:AMPLitudeDescription This sets the expected input level of the master TCH.

Strany 64

Chapter 5 53Remote operationHSCSD Subsystem GPIB CommandsHSCSd:MASTer:UPLink:AMPLitude:CONTrolDescription This defines the relationship between the mas

Strany 65 - HSCSd:MASTer:TCH:TLEVel

54 Chapter5Remote operationHSCSD Subsystem GPIB CommandsHSCSD:MASTer:CALL:TYPEDescription This command selects which type of call the HP/Agilent 8922

Strany 66 - HSCSd:MASTer:UPLink:AMPLitude

Chapter 5 55Remote operationHSCSD Subsystem GPIB CommandsHSCSD:MASTer:CALL:RATEDescription This command selects the data rate of the call that the HP/

Strany 67

viiintended use of the instrument. Agilent Technologies assumes noliability for the customer’s failure to comply with these requirements.WARNING This

Strany 68 - HSCSD:MASTer:CALL:TYPE

56 Chapter5Remote operationHSCSD Subsystem GPIB CommandsHSCSd:SLAVe:STATus:SYNCDescription This read-only field indicates whether or not the slave unit

Strany 69 - HSCSD:MASTer:CALL:RATE

Chapter 5 57Remote operationHSCSD Subsystem GPIB CommandsHSCSd:SLAVe:STATus:TCH:TSLot?Description This query returns the absolute timeslot.For example

Strany 70 - HSCSd:SLAVe:STATus:SYNC

58 Chapter5Remote operationHSCSD Subsystem GPIB CommandsHSCSd:SLAVe:DOWNlink:AMPLitude:OFFSetDescription This sets the amplitude offset (in dBs) of th

Strany 71 - HSCSd:SLAVe:STATus:TCH:TSLot?

Chapter 5 59Remote operationHSCSD Subsystem GPIB CommandsHSCSd:SLAVe:TCH:TLEVelDescription During a call, this sets the Tx level of the slave TCH. Whe

Strany 72

60 Chapter5Remote operationHSCSD Subsystem GPIB CommandsHSCSd:SLAVe:UPLink:AMPLitudeDescription This sets the expected input level of the slave timesl

Strany 73 - HSCSd:SLAVe:TCH:TLEVel

Chapter 5 61Remote operationHSCSD Subsystem GPIB CommandsHSCSd:SLAVe:UPLink:AMPLitude:CONTrolDescription This defines the relationship between the slav

Strany 74 - HSCSd:SLAVe:UPLink:AMPLitude

62 Chapter5Remote operationRemote operating proceduresRemote operating proceduresNOTE For remote operation to work:• the two HP 8922P units must be pu

Strany 75

Chapter 5 63Remote operationRemote operating proceduresEstablishing a callThe procedure for establishing a call is the same as for speech. Notehowever

Strany 76 - Remote operating procedures

64 Chapter5Remote operationRemote operating proceduresChanging channels, timeslot and power levelsPerforming a channel assignment is a single instruct

Strany 77

Chapter 5 65Remote operationRemote operating proceduresEnding a callEnding a call is performed in the same way as for speech.NOTE The master or single

Strany 78

viiiSafety SymbolsThe following symbols on the instrument and in the manual indicateprecautions which must be taken to maintain safe operation of thei

Strany 79

66 Chapter5Remote operationExample code showing a dual-band handover from E-GSM to DCSExample code showing a dual-band handoverfrom E-GSM to DCSSome e

Strany 80

Chapter 5 67Remote operationExample code showing a dual-band handover from E-GSM to DCS350 ! enabled, it will IMMEDIATELY return ENABLED360 !370

Strany 81 - Chapter 5 67

68 Chapter5Remote operationExample code showing a dual-band handover from E-GSM to DCS820 !830 OUTPUT Master;"DualBand:TCHC:Exec"840 OUT

Strany 82 - 68 Chapter5

696 Returning equipment for repair

Strany 83

70 Chapter6Returning equipment for repairReturn ProcedureReturn ProcedureIf you need to return your HP/Agilent 8922 or HP/Agilent 83220 toAgilent Tech

Strany 84 - Return Procedure

Chapter 6 71Returning equipment for repairReturn Procedureenough to accommodate the instrument. Allow at least 7 to 10 cmson all sides of the instrume

Strany 85

72 Chapter6Returning equipment for repairSales and Service OfficesSales and Service OfficesAny adjustment, maintenance, or repair of this product must b

Strany 86 - Sales and Service Offices

Chapter 6 73Returning equipment for repairSales and Service OfficesCanada:Agilent Technologies Canada Inc.5150 Spectrum Way,Mississauga, OntarioL4W 5G1

Strany 87

74 Chapter6Returning equipment for repairSales and Service Offices

Strany 88 - 74 Chapter6

75A Upgrading the HOP ControllerROM and FirmwareThis chapter describes how to upgrade the HOP Controller ROM andfirmware on the HP/Agilent 8922 P to al

Strany 89 - ROM and Firmware

ixThe CE mark shows that the product complies with allrelevant European Legal Directives.ISM 1-A This is a symbol of an Industrial, Scientific, and Med

Strany 90

76 AppendixAUpgrading the HOP Controller ROM and FirmwareUpgrading the Hop Controller ROMUpgrading the Hop Controller ROMCAUTION Perform the following

Strany 91 - SIDE VIEW

Appendix A 77Upgrading the HOP Controller ROM and FirmwareUpgrading the Hop Controller ROMFigure A-1 Removing the top coverStep 3. Remove RF covers A

Strany 92

78 AppendixAUpgrading the HOP Controller ROM and FirmwareUpgrading the Hop Controller ROMFigure A-3 Removing the A33 Hop Controller BoardStep 6. Remov

Strany 93

Appendix A 79Upgrading the HOP Controller ROM and FirmwareUpgrading the Hop Controller ROMStep 8. Reinstall the A33 HOP Controller board.Step 9. Recon

Strany 94 - Upgrading the firmware

80 AppendixAUpgrading the HOP Controller ROM and FirmwareUpgrading the firmwareUpgrading the firmwareThe HP/Agilent 8922 GSM HSCSD Test System host firmw

Komentáře k této Příručce

Žádné komentáře