Shrnutí obsahu

Strany 1 - Agilent Technologies

Agilent TechnologiesInfi niiVision 7000 Series OscilloscopesData SheetEngineered for the best signal visibility

Strany 2 - (source: Prima Data, 2007)

Agilent Infi niiVision 7000 Series oscilloscopes: Engineered for the best signal visibility12.1” large display makes it easier to view analog,digital a

Strany 3 - 3. Insightful applications

Quickly pan and zoom for analysis with MegaZoom III’sinstant response and optimum resolution.Save screen images to a connected USB storage device.Stan

Strany 4

Probes and accessoriesAgilent offers a complete family of innovative passive and active probes for the InfiniiVision 7000 Series scopes helps you get

Strany 5 - Other useful features

Evaluation kit (N2918A)The evaluation kit includes a variety of signals that demonstrate MegaZoom III technology with its fast deep memory, superior w

Strany 6

The 7000 Series scopes come with the most comprehensive connectivity tools in their class.LXI class CLAN eXtensions for Instrumentation (LXI) is a sta

Strany 7

Agilent’s Infi niiVision lineup includes 5000, 6000 and 7000 Series oscilloscopes. These share a number of advanced hardware and software technology b

Strany 8 - Software applications

Performance characteristicsAcquisition: scope channels Sample rate MSO/DSO703xA: 2 GSa/sec each channel MSO/DSO705xA/710xA: 4 GSa/sec half channel

Strany 9

Performance characteristics (continued)Vertical system: scope channelsScope channels MSO/DSO7xx2A: Ch 1 and 2 simultaneous acquisition MSO/DSO7xx4

Strany 10

Performance characteristics (continued)Vertical system: scope channels (continued)ESD tolerance ±2 kVNoise peak-to-peak MSO/DSO703xA: 3% full scale

Strany 11

Performance characteristics (continued)HorizontalRange MSO/DSO703xA: 2 nsec/div to 50 sec/div MSO/DSO705xA: 1 nsec/div to 50 sec/div MSO/DSO710

Strany 12 - Probes and accessories

Agilent has been the fastest growing oscilloscope supplier since 1997 (source: Prima Data, 2007). Wonder why? Agilent engineers developed the Infi ni

Strany 13

Performance characteristics (continued)Trigger system (continued)Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, FlexRay,

Strany 14 - Connectivity

Performance characteristics (continued)Trigger system (continued)Autoscale Finds and displays all active scope and logic (for 7000 Series MSO) channe

Strany 15

Performance characteristics (continued)Display systemDisplay 12.1-inch (255 mm x 184 mm) diagonal color TFT LCDThroughput of scope channels Up to 10

Strany 16 - Performance characteristics

Performance characteristics (continued)StorageSave/recall (non-volatile) 10 setups and traces can be saved and recalled internally. Optional secur

Strany 17 - (continued)

Performance characteristics (continued)General characteristics (continued)Trigger out When Triggers is selected (delay ~17 ns) 0 to 5 V into hi

Strany 18

Ordering informationModel Bandwidth Sample rate Memory depth Scope channels Digital channelsDSO7032A 350 MHz 2 GSa/s 8 Mpts 2 D

Strany 19

Ordering information (continued)OptionsProduct Description U.S. PriceDSO to MSO upgrade* N2735A for DSO703xA, N2736A for DSO705xA,

Strany 20

Related LiteraturePublication Title Publication Type Publication NumberAgilent Technologies Oscilloscope Family Brochure Brochure 5989-7650ENAgilent

Strany 21

www.agilent.com/fi nd/emailupdatesGet the latest information on the products and applications you select. www.agilent.com/fi nd/agilentdirectQuickly

Strany 22

1. Biggest displayOscilloscopes are visual tools and large, high-resolution screens make the product better. Bigger displays have become increasingly

Strany 23

Your design has analog, digital and serial signals ... shouldn’t your scope?The Infi niiVision 7000 Series scope channels provide faster identifi cation

Strany 24

Other useful features High resolution mode. Offers up to 12 bits of vertical resolution in real-time, single-shot mode. This is accomplished by serial

Strany 25 - Ordering information

Why does a fast update rate matter? While bandwidth, sample rate and memory depth are key criteria for deciding which scope to purchase, an equally im

Strany 26

How update rate affects signal visibilityCapturing random and infrequent events on an oscilloscope is all about statistical probabilities. The key to

Strany 27 - Related Literature

Software applicationsI2C/SPI serial trigger and decode (N5423A or Option LSS on new scope purchases)This application displays real-time time-aligned d

Strany 28 - Remove all doubt

Software applicationsFPGA dynamic probe application (N5406A for Xilinx, N5434A for Altera)Give your MSO internal FPGA visibility. Agilent’s MSO FPGA d