Agilent Technologies N1022A Uživatelský manuál Strana 13

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 42
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 12
13
Two new high-bandwidth InfiniiMax II
Series probe amplifiers have been added to
the InfiniiMax product line. InfiniiMax I
probe amplifiers and probe heads can also
be used with DSO 80000 Series scopes for
lower performance applications.
High-Frequency Active Differential/Single-Ended Probe System
Agilent 1168A/69A InfiniiMax II High-Performance Active Probe System
12 GHz Hi-BW
differential
SMA probe
head provides
maximum
bandwidth for
SMA fixtured
differential
pairs.
12 GHz Hi-BW solder-in differential probe
head provides maximum bandwidth and
minimizes capacitive loading to 210 fF.
Variable spacing from 0.2 to 3.3 mm (8 to
130 mills).
12 GHz Hi-BW differential browser provides
maximum bandwidth for hand-held or probe
holder use. Variable spacing from 0.2 to
3.3 mm (8 to 130 mills).
InfiniiMax II: The World’s Best High-Speed
Probing System Just Got Better
InfiniiMax offers you the highest performance
available for measuring differential and
single-ended signals, with flexible connectivity
solutions for today’s high-density ICs and
circuit boards.
InfiniiMax probes have fully characterized
performance for all of their various probe heads.
This includes:
Swept frequency response plot
Common mode rejection vs. frequency plot
Impedance vs. frequency plot
Time-domain probe loading plot
Time-domain probe tracking plot
One-year standard warranty on active probes and
a variety of Agilent support options to choose from.
Controlled impedance transmission lines in every
probe head deliver full performance versus the
performance limitations produced by traditional
wire accessories.
Probe interface software allows you to save the
calibration information for up to 10 different probe
heads per channel and will automatically retrieve
calibration data for a probe amplifier as it is
attached to the scope.
High-input impedance active probes minimize
loading, support differential measurements and DC
offset, and can compensate for cable loss.
Probe calibration software delivers the most
accurate probe measurements, linear phase
response and allows various probe combinations
to be deskewed to the same reference time.
InfiniiMax II probe heads
Zobrazit stránku 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 41 42

Komentáře k této Příručce

Žádné komentáře