Agilent Technologies 34411A Uživatelská příručka Strana 1

Procházejte online nebo si stáhněte Uživatelská příručka pro Multimetry Agilent Technologies 34411A. Agilent Technologies 34411A User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 152
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - 6 ½ Digit Multimeter

Agilent TechnologiesAgilent 34410A/11A 6 ½ Digit Multimeter(includes the L4411A 1U DMM)User’s GuideUG_ED5.book Page 1 Thursday, March 1, 2012 11:28

Strany 2

10 34410A/11A/L4411A User’s GuideThe Display at a Glance (34410A/11A)The following key refers to the primary front-panel display.For further informati

Strany 3 - Safety Information

100 34410A/11A/L4411A User’s Guide4 Measurement TutorialOther Primary Measurement Functions 112Frequency and Period Measurement Errors 112DC Current M

Strany 4 - Ω 4W"). The Protec

34410A/11A/L4411A User’s Guide 101Measurement Tutorial 4DC Measurement ConsiderationsThermal EMF ErrorsThermoelectric voltages are the most common sou

Strany 5 - Additional Notices

102 34410A/11A/L4411A User’s Guide4 Measurement TutorialNoise RejectionRejecting Power–Line Noise VoltagesA desirable characteristic of integrating an

Strany 6 - Standard Limit

34410A/11A/L4411A User’s Guide 103Measurement Tutorial 4Noise Caused by Magnetic LoopsIf you are making measurements near magnetic fields, take cautio

Strany 7 - (true-rms)

104 34410A/11A/L4411A User’s Guide4 Measurement TutorialResistance Measurement ConsiderationsThe multimeter offers two methods for measuring resistanc

Strany 8

34410A/11A/L4411A User’s Guide 105Measurement Tutorial 4Removing Test Lead Resistance ErrorsTo eliminate offset errors associated with the test lead r

Strany 9 - (34410A/11A)

106 34410A/11A/L4411A User’s Guide4 Measurement TutorialTrue RMS AC MeasurementsTrue rms responding multimeters, like the Agilent 34410A/11A/L4411A, m

Strany 10 - Functions”

34410A/11A/L4411A User’s Guide 107Measurement Tutorial 4An ac–coupled true rms measurement is desirable when you are measuring small ac signals in the

Strany 11 - In This Guide…

108 34410A/11A/L4411A User’s Guide4 Measurement TutorialOn the following page, the first figure shows the Fourier Integral of two very different pulse

Strany 12

34410A/11A/L4411A User’s Guide 109Measurement Tutorial 4UG_ED5.book Page 109 Thursday, March 1, 2012 11:28 AM

Strany 13 - Quick Start

34410A/11A/L4411A User’s Guide 11In This Guide…1Quick StartIn this chapter you prepare the multimeter for use and become familiar with the most common

Strany 14 - Basic Multimeter Operations

110 34410A/11A/L4411A User’s Guide4 Measurement TutorialEstimating High–Frequency (Out–of–Band) ErrorA common way to describe signal waveshapes is to

Strany 15 - Front-Panel Keys

34410A/11A/L4411A User’s Guide 111Measurement Tutorial 4The following table shows the typical error for various pulse waveforms as a function of input

Strany 16

112 34410A/11A/L4411A User’s Guide4 Measurement TutorialOther Primary Measurement FunctionsFrequency and Period Measurement ErrorsThe multimeter uses

Strany 17

34410A/11A/L4411A User’s Guide 113Measurement Tutorial 4Capacitance MeasurementsThe multimeter implements capacitance measurements by applying a known

Strany 18 - To M ea s u re A C Vo ltag e

114 34410A/11A/L4411A User’s Guide4 Measurement TutorialThe measurement cycle consists of two parts: a charge phase (shown in the graph) and a dischar

Strany 19 - To Measure AC Current

34410A/11A/L4411A User’s Guide 115Measurement Tutorial 4Temperature MeasurementsThe multimeter allows the measurement of temperature by measurement of

Strany 20 - Resistance

116 34410A/11A/L4411A User’s Guide4 Measurement TutorialAuto Zero On/OffEnabling the auto zero feature (ON) provides greater accuracy; however, the ad

Strany 21 - To M ea s u re Pe riod

34410A/11A/L4411A User’s Guide 117Measurement Tutorial 4High-Speed MeasurementsMaking High–Speed AC MeasurementsThe multimeter's ac voltage and a

Strany 22 - To M ea s u re C apacita nce

118 34410A/11A/L4411A User’s Guide4 Measurement TutorialFor ac voltage, additional settling time may be required when the dc level varies from sample

Strany 23 - Thermistor or RTD

34410A/11A/L4411A User’s Guide 119Measurement Tutorial 4Other Sources of Measurement ErrorSettling Time EffectsThe multimeter has the ability to inser

Strany 24 - ~ 0.8V (not adjustable)

12 34410A/11A/L4411A User’s GuideUG_ED5.book Page 12 Thursday, March 1, 2012 11:28 AM

Strany 25 - Other Basics of Operation

120 34410A/11A/L4411A User’s Guide4 Measurement TutorialMeasurements Below Full ScaleYou can make the most accurate ac measurements when the multimete

Strany 26 - 1Quick Start

34410A/11A/L4411A User’s Guide 121Measurement Tutorial 4susceptible to noise pickup than a low–impedance source. You can reduce the high–frequency imp

Strany 27 - To Adjust the Carrying Handle

122 34410A/11A/L4411A User’s Guide4 Measurement TutorialCommon Mode ErrorsErrors are generated when the multimeter's input LO terminal is driven

Strany 28

123Agilent 34410A/11A/L4411A 6½ Digit MultimeterUser’s GuideAgilent Technologies5SpecificationsDC Characteristics 125AC Characteristics 128Frequency a

Strany 29 - Contents

124 34410A/11A/L4411A User’s Guide5 SpecificationsThese specifications apply when using the 34410A/11A/L4411A multimeter in an environment that is fre

Strany 30

34410A/11A/L4411A User’s Guide 125Specifications 5DC CharacteristicsAccuracy Specifications ±( % of reading + % of range ) [1][ 1 ] Specifications are

Strany 31

126 34410A/11A/L4411A User’s Guide5 SpecificationsPerformance Versus Integration Time – 60Hz (50Hz) Power line frequency[ 1 ] Resolution is defined as

Strany 32

34410A/11A/L4411A User’s Guide 127Specifications 5DC VoltageMeasurement Method: Continuously integrating multi–slope IV A/D converter10 VDC Linearity

Strany 33

128 34410A/11A/L4411A User’s Guide5 SpecificationsAC CharacteristicsAccuracy Specifications ±( % of reading + % of range ) [1][ 1 ] Specifications are

Strany 34

34410A/11A/L4411A User’s Guide 129Specifications 5Voltage Transfer Accuracy ( typical )Frequency Error 10 Hz to 300 kHz (24 hour % of range + % of re

Strany 35 - Features and Functions

13Agilent 34410A/11A/L4411A 6½ Digit MultimeterUser’s GuideAgilent Technologies1Quick StartThis chapter gives you a quick overview of the 34410A/11A m

Strany 36 - Power-On and Reset State 85

130 34410A/11A/L4411A User’s Guide5 SpecificationsFrequency and Period CharacteristicsAccuracy Specifications ±( % of reading ) [ 1, 3 ]Additional Err

Strany 37 - SCPI Commands

34410A/11A/L4411A User’s Guide 131Specifications 5Frequency and PeriodMeasurement Type: Reciprocal–counting technique. AC–coupled input using the AC v

Strany 38 - Front Panel Display

132 34410A/11A/L4411A User’s Guide5 SpecificationsCapacitance CharacteristicsAccuracy Specifications ±( % of reading + % of range ) [1][ 1 ] Specifica

Strany 39

34410A/11A/L4411A User’s Guide 133Specifications 5Additional 34411A/L4411A SpecificationsResolution See table on page 126Overall Bandwidth, DCV and DC

Strany 40 - Annunciators

134 34410A/11A/L4411A User’s Guide5 SpecificationsMeasurement and System SpeedsDMM Measurements Speeds[1] Typical. Display off, ½ scale input signal,

Strany 41 - <feed>

34410A/11A/L4411A User’s Guide 135Specifications 5Direct I/O Measurements [1] (any remote interface)Sustained maximum reading rate to I/O, 32–bit BINA

Strany 42 - ManRng annunciator

136 34410A/11A/L4411A User’s Guide5 SpecificationsData From MemoryMaximum reading rate out of memory (Sample count 50000, trigger count 1, "FETC?

Strany 43

34410A/11A/L4411A User’s Guide 137Specifications 5General Specifications (L4411A)Power supply: Universal 100V to 240V ±10%Power line frequency: 45 H

Strany 44

138 34410A/11A/L4411A User’s Guide5 SpecificationsDimensionsAll dimensions are shown in millimeters212.3363.240.9UG_ED5.book Page 138 Thursday, Marc

Strany 45

34410A/11A/L4411A User’s Guide 139Specifications 5To Calculate Total Measurement ErrorThe multimeter's accuracy specifications are expressed in t

Strany 46

14 34410A/11A/L4411A User’s Guide1Quick StartBasic Multimeter OperationsThis section introduces the basics of the 34410A/11A multimeter, and how to us

Strany 47 - Continuity and Diode Tests

140 34410A/11A/L4411A User’s Guide5 SpecificationsUnderstanding the " % of range " Error The range error compensates for inaccuracies that r

Strany 48 - Multimeter State Storage

34410A/11A/L4411A User’s Guide 141Specifications 5Interpreting Accuracy SpecificationsTrans fe r A c cur ac yTransfer accuracy refers to the error in

Strany 49 - Accessing Reading Memory

142 34410A/11A/L4411A User’s Guide5 SpecificationsConfiguring for Highest Accuracy MeasurementsThe measurement configurations shown below assume that

Strany 50 - Multimeter Reset

143Agilent 34410A/11A/L4411A 6½ Digit Multimeter User’s GuideAgilent TechnologiesAAppendix: Firmware and Driver UpdatesFirmware and (IVI-COM) driver u

Strany 51 - DC Measurements

144 34410A/11A/L4411A User’s GuideA Appendix: Firmware and Driver UpdatesDownloading the Update Utility and Firmware Agilent 34410A/11A firmware updat

Strany 52

34410A/11A/L4411A User’s Guide 145Appendix: Firmware and Driver Updates A1. From the directory where the update utility was installed, start the utili

Strany 53 - DC Input Impedance

146 34410A/11A/L4411A User’s GuideA Appendix: Firmware and Driver Updates3. Select the I/O interface to the instrument and then select ‘Next’. Enter t

Strany 54 - AC Measurements

34410A/11A/L4411A User’s Guide 147Appendix: Firmware and Driver Updates ADownloading IVI-COM Driver UpdatesAn IVI-COM driver for the 34410A/11A is pro

Strany 55 - Gate Time

148 34410A/11A/L4411A User’s GuideA Appendix: Firmware and Driver UpdatesUG_ED5.book Page 148 Thursday, March 1, 2012 11:28 AM

Strany 56 - <function>

34410A/11A/L4411A User’s Guide 5IndexNumerics1-Year Specifications, 14124-hour accuracy, 14134410A, 7firmware updates, 14434411A, 7firmware updates, 1

Strany 57

34410A/11A/L4411A User’s Guide 15Quick Start 1Using the Front Panel (34410A/11A)This section introduces the 34410A/11A multimeter front panel.Front-Pa

Strany 58

6 34410A/11A/L4411A User’s GuideIndexFFactory Settings, 85firmware updatesdownloads, 144installation, 144update utility, 144Frequency Measurements, 21

Strany 59 - Null Measurements

34410A/11A/L4411A User’s Guide 7IndexPPeriod Measurements, 21Configuring, 46Configuring for Accuracy, 142Errors In, 112Specifications, 130Power Dissip

Strany 60 - Radix Character (34410A/11A)

8 34410A/11A/L4411A User’s GuideIndexWWaste Electrical and Electronic Equipment Directive, 5Web Browser, 98Web Password, 91, 95UG_ED5.book Page 8 Th

Strany 61 - Beeper (34410A/11A)

16 34410A/11A/L4411A User’s Guide1Quick StartFront-Panel Display Shortcuts Direct front panel shortcuts are provided for three commonly used display f

Strany 62 - Math Functions

34410A/11A/L4411A User’s Guide 17Quick Start 1Making Basic Measurements (34410A/11A)This section introduces the many types of measurements that you ca

Strany 63

18 34410A/11A/L4411A User’s Guide1Quick StartTo Measure DC VoltagePress to select the dc voltage function.• Ranges: 100 mV, 1 V, 10 V, 100 V, 1000 V

Strany 64

34410A/11A/L4411A User’s Guide 19Quick Start 1To Measure DC CurrentPress to select the dc current function.• Ranges: 100 mA, 1 mA, 10 mA, 100 mA, 1

Strany 65 - Using Statistics

2 34410A/11A/L4411A User’s GuideNotices© Agilent Technologies, Inc. 2005-2012No part of this manual may be reproduced in any form or by any means (inc

Strany 66 - Limit Testing

20 34410A/11A/L4411A User’s Guide1Quick StartTo Make a 2-Wire Resistance MeasurementPress to select the 2-wire resistance function.• Ranges: 100Ω, 1

Strany 67 - Triggering the Multimeter

34410A/11A/L4411A User’s Guide 21Quick Start 1To Measure Frequency Press to select the frequency function.• Measurement band: 3 Hz to 300 kHz • Inpu

Strany 68 - Auto Triggering (34410A/11A)

22 34410A/11A/L4411A User’s Guide1Quick StartTo M ea s u re C apacita ncePress to select the capacitance function.• Ranges: 1 nF, 10 nF, 100 nF, 1 m

Strany 69 - Immediate Triggering

34410A/11A/L4411A User’s Guide 23Quick Start 1To Make a 2-Wire Temperature MeasurementPress to select the temperature function. Then press and sel

Strany 70 - <level>

24 34410A/11A/L4411A User’s Guide1Quick StartTo Test C ontinu ityPress to select the continuity function. • Test current source: 1 mA• Beeper Thres

Strany 71 - Number of Samples per Trigger

34410A/11A/L4411A User’s Guide 25Quick Start 1Other Basics of OperationThis section covers basic troubleshooting and general use.If the Multimeter Doe

Strany 72 - Trigger Delay

26 34410A/11A/L4411A User’s Guide1Quick StartTo Replace the Power-Line Fuse (34410A/11A)Remove power cord first. Then follow these steps:Verify that t

Strany 73 - Automatic Trigger Delay

34410A/11A/L4411A User’s Guide 27Quick Start 1To Adjust the Carrying HandleTo adjust the position, grasp the handle by the sides and pull outward. The

Strany 74

28 34410A/11A/L4411A User’s Guide1Quick StartTo Rack Mount the Multimeter (34410A/11A)You can mount the 34410A/11A in a standard 19–inch rack cabinet

Strany 75 - External Triggering

34410A/11A User’s Guide 29Contents 1Quick Start13Basic Multimeter Operations 14Preparing the Multimeter for Use 14Using the Front Panel (34410A/11A) 1

Strany 76

34410A/11A/L4411A User’s Guide 3Safety InformationDo not defeat power cord safety ground fea-ture. Plug in to a grounded (earthed) outlet. Do not use

Strany 77 - Trigger Slope

30 34410A/11A/L4411A User’s GuideContents2 Features and Functions 35SCPI Commands 37Front Panel Features (34410A/11A) 38Front Panel Display 38Displaye

Strany 78 - Data Logging

Contents34410A/11A/L4411A User’s Guide 31Auto Zero 56Ranging 57Null Measurements 59Miscellaneous Configuration Settings 60Radix Character (34410A/11A)

Strany 79

32 34410A/11A/L4411A User’s GuideContents3 Remote Interface Configuration 87Configuring the GPIB Interface 89Configuring the USB Interface 90Configuri

Strany 80

Contents34410A/11A/L4411A User’s Guide 33True RMS AC Measurements 106True RMS Accuracy and High–Frequency Signal Content 107Estimating High–Frequenc

Strany 81

34 34410A/11A/L4411A User’s GuideContents5 Specifications 123DC Characteristics 125AC Characteristics 128Frequency and Period Characteristics 130Capac

Strany 82 - System-Related Operations

35Agilent 34410A/11A/L4411A 6½ Digit Multimeter User’s GuideAgilent Technologies2Features and FunctionsSCPI Commands 37Front Panel Features (34410A/11

Strany 83 - Error Conditions

36 34410A/11A/L4411A User’s Guide2Features and FunctionsAC Measurements 54AC Filter 54Gate Time 55Auto Zero 56Ranging 57Null Measurements 59Miscellane

Strany 84 - Calibration

34410A/11A/L4411A User’s Guide 37Features and Functions 2SCPI CommandsThe Agilent 34410A/11A/L4411A complies with the syntax rules and conventions of

Strany 85 - Power-On and Reset State

38 34410A/11A/L4411A User’s Guide2Features and FunctionsFront Panel Features (34410A/11A)Front Panel DisplayThe Agilent 34410A/11A provides a two–line

Strany 86 - Enabled

34410A/11A/L4411A User’s Guide 39Features and Functions 2• If the multimeter is in the remote interface mode (Remote annunciator is lit), pressing (

Strany 87

4 34410A/11A/L4411A User’s GuideProtection LimitsThe Agilent 34410A/11A and L4411A Digital Multimeters provide protection circuitry to prevent damage

Strany 88 - Remote annunciator turns

40 34410A/11A/L4411A User’s Guide2Features and FunctionsAnnunciatorsThere are several annunciators, mostly in a line at the top of the display. Each a

Strany 89

34410A/11A/L4411A User’s Guide 41Features and Functions 2Second Display OptionsMany measurement functions allow a secondary measurement to be displaye

Strany 90 - Configuring the USB Interface

42 34410A/11A/L4411A User’s Guide2Features and FunctionsFront–Panel Display Shortcuts Direct front–panel shortcuts are provided for three commonly use

Strany 91 - Configuring the LAN Interface

34410A/11A/L4411A User’s Guide 43Features and Functions 2• If the multimeter is configured to take the measurement using an aperture integration time,

Strany 92 - Configuring LAN Parameters

44 34410A/11A/L4411A User’s Guide2Features and FunctionsFront Panel Measurement Configuration MenusEach measurement function is configured separately,

Strany 93 - Subnet Mask

34410A/11A/L4411A User’s Guide 45Features and Functions 2Configuring AC Voltage and Current MeasurementsFor ac voltage and ac current measurements, yo

Strany 94 - Host Name

46 34410A/11A/L4411A User’s Guide2Features and FunctionsConfiguring Frequency and Period MeasurementsFor frequency and period measurements, your menu

Strany 95 - Web Password

34410A/11A/L4411A User’s Guide 47Features and Functions 2• NULL: Allows you to enable (ON) or disable (OFF) the null measurement feature, which measur

Strany 96

48 34410A/11A/L4411A User’s Guide2Features and FunctionsAdvanced Configuration OptionsMultimeter State StorageThe present multimeter state, including

Strany 97

34410A/11A/L4411A User’s Guide 49Features and Functions 2• Remote Interface Operation: Refer to the MEMory command subsystem in the Agilent 34410A/11A

Strany 98

34410A/11A/L4411A User’s Guide 5Additional NoticesWaste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ECThis product complies with the

Strany 99 - Measurement Tutorial

50 34410A/11A/L4411A User’s Guide2Features and Functions• Remote Interface Operation: The Front/Rear switch is manually switchable only, and cannot be

Strany 100 - High-Speed Measurements 117

34410A/11A/L4411A User’s Guide 51Features and Functions 2DC Measurements Integration Time and ResolutionFor dc voltage, dc current, resistance, and te

Strany 101 - DC Measurement Considerations

52 34410A/11A/L4411A User’s Guide2Features and Functions• Remote Interface Operation: The following commands set the integration time in NPLC:[SENSe:]

Strany 102 - Noise Rejection

34410A/11A/L4411A User’s Guide 53Features and Functions 2The following command (similar queries for current, resistance and temperature) returns wheth

Strany 103 - Noise Caused by Ground Loops

54 34410A/11A/L4411A User’s Guide2Features and FunctionsAC MeasurementsAC FilterApplies to ac voltage, ac current, frequency, and period measurements

Strany 104 - 4–Wire Ohms Measurements

34410A/11A/L4411A User’s Guide 55Features and Functions 2Gate Time Applies to frequency and period measurements only.The multimeter provides four choi

Strany 105

56 34410A/11A/L4411A User’s Guide2Features and FunctionsAuto ZeroAuto zero is selectable for dc voltage, dc current, 2–wire resistance, and 2-wire tem

Strany 106 - True RMS AC Measurements

34410A/11A/L4411A User’s Guide 57Features and Functions 2RangingApplies to all measurements except continuity and diode test, which use a fixed range.

Strany 107

58 34410A/11A/L4411A User’s Guide2Features and Functions• Remote Interface Operation: Autoranging may be enabled or disabled for the specified functio

Strany 108

34410A/11A/L4411A User’s Guide 59Features and Functions 2The first four readings are taken on the 1 Vdc range, but the autoranging feature switches to

Strany 109 - Measurement Tutorial 4

6 34410A/11A/L4411A User’s GuideDECLARATION OF CONFORMITYAccording to EN ISO/IEC 17050-1:2004Manufacturer’s Name: Agilent Technologies, IncorporatedMa

Strany 110

60 34410A/11A/L4411A User’s Guide2Features and FunctionsThe following command queries the null measurement feature setting:SENSe:<function>:NULL

Strany 111 - 10, provided there

34410A/11A/L4411A User’s Guide 61Features and Functions 2Beeper (34410A/11A)Normally, the multimeter emits a tone from the front panel whenever certai

Strany 112 - DC Current Measurements

62 34410A/11A/L4411A User’s Guide2Features and FunctionsMath FunctionsIn addition to providing a separate null–per–function measurement capability, th

Strany 113 - Capacitance Measurements

34410A/11A/L4411A User’s Guide 63Features and Functions 2dB MeasurementsApplies to ac voltage and dc voltage measurements only.Each dB measurement is

Strany 114

64 34410A/11A/L4411A User’s Guide2Features and FunctionsdBm MeasurementsApplies to ac voltage and dc voltage measurements only.The dBm function is log

Strany 115 - Temperature Measurements

34410A/11A/L4411A User’s Guide 65Features and Functions 2Using StatisticsApplies to all measurement functions except continuity and diode test.From th

Strany 116 - NULL Reading:

66 34410A/11A/L4411A User’s Guide2Features and FunctionsLimit TestingApplies to all measurement functions except continuity and diode test.The limit t

Strany 117 - High-Speed Measurements

34410A/11A/L4411A User’s Guide 67Features and Functions 2Triggering the MultimeterThe 34410A/11A/L4411A triggering system allows you to generate trigg

Strany 118

68 34410A/11A/L4411A User’s Guide2Features and FunctionsAuto Triggering (34410A/11A)This mode is available from the front panel only.The power–on trig

Strany 119 - Loading Errors (ac volts)

34410A/11A/L4411A User’s Guide 69Features and Functions 2Reading Hold (34410A/11A)This mode is available from the front panel only.The reading hold mo

Strany 120 - Low–Level Measurement Errors

34410A/11A/L4411A User’s Guide 7Agilent 34410A/11A/L4411A at a GlanceThe Agilent 34410A, 34411A, and L4411A multimeters provide 6½-digit, high-perform

Strany 121

70 34410A/11A/L4411A User’s Guide2Features and FunctionsSoftware (Bus) TriggeringThis mode is available from the remote interface only.The bus trigger

Strany 122 - Leakage Current Errors

34410A/11A/L4411A User’s Guide 71Features and Functions 2Number of Samples per TriggerBy default, when the multimeter is in the wait–for–trigger state

Strany 123 - Specifications

72 34410A/11A/L4411A User’s Guide2Features and Functions• Remote Interface Operation: The following commands set the sample count (must be >1) and

Strany 124

34410A/11A/L4411A User’s Guide 73Features and Functions 2If the multimeter is configured to take more than one sample per trigger, the effect of the t

Strany 125 - DC Characteristics

74 34410A/11A/L4411A User’s Guide2Features and Functions2–wire Resistance Measurements:4–wire Resistance MeasurementsCapacitanceAC Voltage Measurement

Strany 126 - Trans fe r Accuracy (Typical)

34410A/11A/L4411A User’s Guide 75Features and Functions 2External TriggeringExternal triggering takes one reading (or the specified number of readings

Strany 127

76 34410A/11A/L4411A User’s Guide2Features and Functions• Front Panel Operation: The external trigger mode corresponds in function to pressing the k

Strany 128 - AC Characteristics

34410A/11A/L4411A User’s Guide 77Features and Functions 2Trigger SlopeYou may select whether the multimeter uses the rising edge (POS) or falling edge

Strany 129

78 34410A/11A/L4411A User’s Guide2Features and FunctionsData LoggingThe Data Logger feature (34410A/11A only) provides a front–panel user interface th

Strany 130

34410A/11A/L4411A User’s Guide 79Features and Functions 2• After the specified delay, the main display will show the data as it is collected, while th

Strany 131 - Settling Considerations

8 34410A/11A/L4411A User’s GuideThe Front Panel at a Glance (34410A/11A)WARNINGFront/Rear Switch: Do not change the position of the Front/Rear switch

Strany 132 - Temperature Characteristics

80 34410A/11A/L4411A User’s Guide2Features and Functions• Web Interface Operation: To access the data in the multimeter’s non–volatile memory, launch

Strany 133

34410A/11A/L4411A User’s Guide 81Features and Functions 2Now click on View Data. In the dialog, select Non–volatile Memory Readings and then click on

Strany 134 - Measurement and System Speeds

82 34410A/11A/L4411A User’s Guide2Features and FunctionsSystem-Related OperationsThe utility menu accesses the following system–related operations: se

Strany 135 - System Speeds

34410A/11A/L4411A User’s Guide 83Features and Functions 2Error ConditionsWhen the front panel ERROR annunciator turns on (34410A/11A), one or more com

Strany 136 - Data From Memory

84 34410A/11A/L4411A User’s Guide2Features and FunctionsReading the Error QueueYou can read the error queue either from the front panel, or from the r

Strany 137 - Triggering and Memory

34410A/11A/L4411A User’s Guide 85Features and Functions 2Power-On and Reset StateThe tables that follow show the factory defaults for various instrume

Strany 138 - Dimensions

86 34410A/11A/L4411A User’s Guide2Features and Functions● Thousands Separator (34410A/11A) ● OnDisplay State (34410A/11A) OnReading Memory ClearedErro

Strany 139

87Agilent 34410A/11A/L4411A 6½ Digit Multimeter User’s GuideAgilent Technologies3 Remote Interface ConfigurationConfiguring the GPIB Interface 89Confi

Strany 140 - \30 ppm of 5 VDC

88 34410A/11A/L4411A User’s Guide3 Remote Interface ConfigurationThis chapter tells how to configure the Agilent 34410A/11A for remote interface commu

Strany 141 - Temperature Coefficients

34410A/11A/L4411A User’s Guide 89Remote Interface Configuration 3Configuring the GPIB InterfaceEach device on the GPIB (IEEE–488) interface must have

Strany 142 - for dc voltage measurements

34410A/11A/L4411A User’s Guide 9The Rear Panel at a Glance (34410A/11A)WARNINGFor protection from electrical shock, the power cord ground must not be

Strany 143 - Agilent Technologies

90 34410A/11A/L4411A User’s Guide3 Remote Interface ConfigurationConfiguring the USB InterfaceFor the USB interface, no configuration parameters are r

Strany 144 - √ Documents & Downloads

34410A/11A/L4411A User’s Guide 91Remote Interface Configuration 3Configuring the LAN InterfaceBy default, LAN connectivity with DHCP (Dynamic Host Con

Strany 145

92 34410A/11A/L4411A User’s Guide3 Remote Interface ConfigurationConfiguring LAN ParametersDHCP DHCP is a protocol for automatically assigning a dynam

Strany 146

34410A/11A/L4411A User’s Guide 93Remote Interface Configuration 3IP Address An Internet Protocol (IP) Address is required for all IP and TCP/IP commun

Strany 147 - √ Instrument Drivers

94 34410A/11A/L4411A User’s Guide3 Remote Interface ConfigurationDefault GatewayA Default Gateway address allows the multimeter to communicate with sy

Strany 148

34410A/11A/L4411A User’s Guide 95Remote Interface Configuration 3DNS ServerThe Domain Name Service (DNS) is an Internet service that translates Domain

Strany 149

96 34410A/11A/L4411A User’s Guide3 Remote Interface ConfigurationSetting up a LAN connection from the Front PanelPress UTILITY MENU > REMOTE I/O &

Strany 150

34410A/11A/L4411A User’s Guide 97Remote Interface Configuration 3Setting up a LAN connection from the Remote InterfaceUse the following SCPI commands

Strany 151

98 34410A/11A/L4411A User’s Guide3 Remote Interface ConfigurationAgilent 34410A/11A Web Interface The 34410A/11A provides a built–in Web Interface. Yo

Strany 152 - Web Password, 91, 95

99Agilent 34410A/11A/L4411A 6½ Digit Multimeter User’s GuideAgilent Technologies4Measurement TutorialThe Agilent 34410A/11A/L4411A multimeter is capab

Komentáře k této Příručce

Žádné komentáře