Vector- and scalar-calibrated converter measurements
(Option 083)
This converter measurement is a superset and includes not
only the scalar-calibrated converter measurement, but
also the vector-mixer calibration (VMC). The advanced and
unique VMC delivers exceptional conversion loss amplitude
and phase accuracy for mixer and converter measurements.
This application provides an intuitive and easy-to-use user
interface for setting up mixer and converter measurements,
with single or dual conversion stages (up to two LO’s), along
with control of up to two external signal generators for use as
LO.External synthesizers supported include the Agilent ESG
series and the PSG series of signal source families as well as
other SCPI controlled signal generators. Option 083 requires
Option 080, and cannot be ordered with Option 082.
Embedded LO measurements (Option 084)
Advanced software tuning that provides absolute group delay of
converters with embedded LOs without the need for access to a
common reference signal. The measurement result is the same
as locking the DUT LO to the reference mixer LO. (Option 080
and 083 required) Requires firmware A.07.50 and above.
Gain compression application (Option 086)
The Gain Compression Application (GCA) provides input power,
output power, gain, and phase at an amplifier's compression
point, over a specified frequency and power range. GCA's
SMART Sweep is very fast and easy-to-use. GCA also includes
a guided calibration that corrects for absolute power levels,
frequency response, and mismatch errors. Requires firmware
A.08.00 and above
N-port capabilities (Option 551)
1
Adds full N-port error correction and measurement capabilities
to the PNA-X network analyzer. External test set is required.
High-power test set (Option H85)
With the standard test set confi gurations that include source
attenuators, the internal bias tees limit the maximum test port
power to +30 dBm. Option H85 removes the bias tees
between the source attenuators and the test port couplers.
This extends the maximum port power that the analyzer can
safely handle to +43 dBm. Option H85 requires Option 080,
plus Option 224 or 423.
Rack mount kit without handles (Option 1CM)
Adds a rack mount (5063-9217) and rail kit (E3663AC) for use
without handles.
1. When configured as a multiport analyzer with Option 551, the
combiner feature of Option 224 or 423 is not available. When configured
as a standalone analyzer, the combiner feature is available.
Pulse I/O adapter (N1966A)
An adapter for connecting between the Pulse I/O connector on
the rear panel of the PNA-X and the coaxial inputs and outputs
of external pulse generators and external pulse modulators.
Coaxial connectors are SMB-male. (See diagram below for
details of the Pulse I/O adapter.
The PULSE IN connectors are for controlling the PNA-X's internal
IF gates, which are enabled with Option H08 and used with
narrowband detection. The PULSE OUT connectors are from the
PNA-X's four internal pulse generators, which are enabled with
Option 025. The PULSE SYNC IN connector is used to synchronize
the internal pulse generators with an external timing pulse. The
RF PULSE MOD IN connector controls the internal pulse modulator(s)
which are enabled with Options 021 and 022.
Pulse I/O adapter (N1966A) simplifies connections
PNA-X Network Analyzer