Agilent Technologies E6392B Uživatelská příručka Strana 110

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 206
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 109
Chapter 3 109
Screen Reference
MANUAL TEST (Asynchronous Mode)
3. Screen Reference
If the Abort softkey is pressed, another softkey menu is shown to activate the
trigger mode, zooming and marker functions as shown in Figure 3-37.
Figure 3-37 Aborted: Peak TX Power/Burst Timing/Power Ramp Screen
Figure 3-38 Aborted: Peak TX Power/Burst Timing/Power Ramp Zoomed Screen
Softkey Menu 1
o Start: Begins a new measurement cycle with either single or continuous
trigger mode.
o Trigger Sing/Cont: Toggles the trigger mode between Sing
for single and
Cont
for continuous modes. In the continuous mode, this softkey is
highlighted blinking until the Abort softkey is pressed. In the single mode,
this softkey is highlighted for one measurement cycle and the marker
function is available with the Knob MKR/Cursor softkey.
o Zoom Off/On: Toggles the zooming function between Off and On. If On is
selected, the rising edge, from 8 bit to 0 bit, and trailing edge, between bits
147 and 155, of the Power Ramp are expanded to observe the detailed test
results as shown in Figure 3-38.
o More (1 of 3): Displays softkey menu 2.
o Return: Returns to the initial Measuring screen as shown in Figure 3-35.
Softkey Menu 2
Zobrazit stránku 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 205 206

Komentáře k této Příručce

Žádné komentáře