Agilent Technologies N9360A Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě Agilent Technologies N9360A. Agilent Technologies N9360A User manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 354
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Multi UE Tester

Agilent Technologies Agilent N9360A Multi UE TesterGSM User Manual

Strany 2

10 N9360A Multi UE Tester GSM User Manual Figure 5-40. [Measuring] Sensitivity/ RX Quality/ RX Level Screen 5-68Figure 5-41. [Measuring] Spectrum

Strany 3 - Trademarks

4-70 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 12When the attached process is succeeded, the Tester waits for the trigger.• Wh

Strany 4

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-71 Step 13During continuous measurement, change the trigger mode from Cont to Sing to t

Strany 5 - Contents

4-72 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 15Select a group of measurement items with the CURSOR CONTROL knob to display t

Strany 6

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-73 Step 16Press a softkey as needed.Knob Cur/Marker: Selects the cursor or the marker.M

Strany 7 - List Of Figures

4-74 N9360A Multi UE Tester GSM User Manual4 Operating Procedures More (1 of 2): Displays the softkey menu 2.Return: Returns to the previous screen.Pr

Strany 8

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-75 Step 18Press the Trigger softkey to measure spectrum in single mode, or the Trigger

Strany 9

4-76 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 1Turn on the Tester and select the GSM system on the [Top Menu] screen. Refer t

Strany 10

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-77 Step 4Press the Test Condition softkey to display the [Configuration: Test Condition

Strany 11 - 6 Troubleshooting

4-78 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 5Set the input fields of the test parameter as shown in Figure 4-68.Step 6Enter

Strany 12

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-79 Step 8Set the mobile phone to transmit the bursted RF signal.Step 9Start a test with

Strany 13 - List Of Tables

N9360A Multi UE Tester GSM User Manual 11 Figure 5-76. [Configuration: Test Condition] (GSM Mode) Screen 5-177Figure 5-77. [Configuration: Test C

Strany 14

4-80 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 10During continuous measurement, press the Trigger Si ng/Cont softkey to termin

Strany 15

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-81 Step 12Press a softkey as needed.Knob Cur/Marker: Selects the cursor or the marker.M

Strany 16

4-82 N9360A Multi UE Tester GSM User Manual4 Operating Procedures More (1 of 2): Displays the softkey menu 2.Return: Returns to the previous screen.Pr

Strany 17 - Legal Information

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-83 Step 14Press the Trigger softkey to measure spectrum in single mode, or the Trigger

Strany 18

4-84 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 2The [Initial] screen as Figure 4-74 is displayed after completion of initializ

Strany 19 - Service And Support

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-85 Step 4Press the Return and then the Signal Generator softkey on the [Initial] screen

Strany 20 - 1 Legal Information

4-86 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 5Set the input fields.Step 6Press the RF Output On/Off softkey to change On/Off

Strany 21 - Agilent Technologies

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-87 Ending a TestDisconnecting the Mobile PhoneDisconnect the mobile phone from the conn

Strany 22 - Safety Information

4-88 N9360A Multi UE Tester GSM User Manual4 Operating Procedures THIS PAGE IS INTENTIONALLY LEFT BLANK

Strany 23 - When Operating The Tester

5-1 Agilent Technologies5Screen ReferenceScreen Flow Chart 5-2Top Menu Screen 5-3Firmware Update Screen 5-10Initial Screen 5-12Return to

Strany 24

12 N9360A Multi UE Tester GSM User Manual THIS PAGE IS INTENTIONALLY LEFT BLANK.

Strany 25 - Overview

5-2 N9360A Multi UE Tester GSM User Manual5 Screen Reference Screen Flow ChartThe following Figure 5-1 shows the screen flow chart for each function m

Strany 26 - Functions

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-3 Top Menu ScreenAfter power on, the [Top Menu] screen as Figure 5-2 is displayed.This scre

Strany 27 - Table 3-1 Main Functions

5-4 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• GSM: Selects the GSM system. After the system is selected

Strany 28 - Features

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-5 Screen FieldThe firmware name, revision number currently installed, and serial number are

Strany 29 - Standard Configuration

5-6 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves it

Strany 30 - Accessories

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-7 When the Option E01 is not installed in the Tester, the Serial Port GP-IB field is displa

Strany 31 - Operating Procedures

5-8 N9360A Multi UE Tester GSM User Manual5 Screen Reference Also, the following information is shown in the screen field:• MAC Address• Serial No.• O

Strany 32 - Test Flo w

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-9 Option Installation/BackupInstallation/Backup of options such as G00 and W00 can be contr

Strany 33 - Preparation for Each Test

5-10 N9360A Multi UE Tester GSM User Manual5 Screen Reference Step 2Insert USB memory device containing the Option Key into the USB connector on the f

Strany 34 - Connection

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-11 Softkey Menu FieldSoftkey Menu 1• Update Menu: Updates the Menu function.This softkey is

Strany 35 - Test Pro cedu re

N9360A Multi UE Tester GSM User Manual 13 List Of Tables1 Legal InformationTable 1-1. Agilent Call Centers and Regional Headquarters 1-33Overview

Strany 36

5-12 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file of

Strany 37

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-13 Softkey Menu FieldSoftkey Menu• Automatic Test: Displays the [Automatic Test: Stand-by]

Strany 38

5-14 N9360A Multi UE Tester GSM User Manual5 Screen Reference Screen FieldThe firmware name and revision number currently installed are shown.Set the

Strany 39

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-15 Return to Menu ScreenWhen the Return to Menu softkey is pressed on the [Initial] screen,

Strany 40

5-16 N9360A Multi UE Tester GSM User Manual5 Screen Reference Automatic TestFeature of Automatic TestThe test flow set on the [Configuration: Test Con

Strany 41

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-17 (Figure 5-11), or the [Automatic Test: Stand-by] value screen (Figure 5-12) is displayed

Strany 42

5-18 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Start: Starts testing the mobile phone by Automatic Te

Strany 43 - Selection of System

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-19 Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file of

Strany 44

5-20 N9360A Multi UE Tester GSM User Manual5 Screen Reference Table 5-4 describes measurement items in Automatic Test. The limits for measurement item

Strany 45 - None. For details, see

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-21 The Radio System(s) (GSM850, GSM900, DCS1800, PCS1900) is or are shown.If some test item

Strany 46

14 N9360A Multi UE Tester GSM User Manual Table 5-19. [Manual Test] GSM Mode Peak TX Power/Burst Timing/Power Ramp Screen Field 5-64Table 5-20. [

Strany 47 - Correction

5-22 N9360A Multi UE Tester GSM User Manual5 Screen Reference The word surrounded by {} in the message field denotes the softkey.Measuring Screen When

Strany 48

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-23 Figure 5-13 [Measuring] Simplified ScreenFigure 5-14 [Measuring] Detailed Screen

Strany 49

5-24 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Screen>>: Displays the softkey menu 2 containing

Strany 50

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-25 Screen FieldThe information from the mobile phone as Table 5-6 is displayed in the scree

Strany 51

5-26 N9360A Multi UE Tester GSM User Manual5 Screen Reference Figure 5-16 [Measuring] Talk Simplified ScreenFigure 5-17 [Measuring] Talk Detailed Scre

Strany 52

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-27 Softkey Menu FieldSoftkey Menu 1• Pass: Press this softkey if your voice loops back from

Strany 53

5-28 N9360A Multi UE Tester GSM User Manual5 Screen Reference • Value: Displays a measurement value at each item cell in the measurement result field.

Strany 54

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-29 Softkey Menu FieldSoftkey Menu 1• Start: Starts testing the mobile phone by Automatic Te

Strany 55

5-30 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu 3• Simple: Displays a Pass/Fail result of whole measurement in the middle o

Strany 56

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-31 • F: Shown on red background when the test is failed.When Sequence 2 starts, the [Automa

Strany 57

N9360A Multi UE Tester GSM User Manual 15 Table 5-46. [Manual Test: Measuring] EGPRS Mode Screen Input Field 5-111Table 5-47. [Manual Test] EGPRS

Strany 58

5-32 N9360A Multi UE Tester GSM User Manual5 Screen Reference Summary ScreenWhen all tests in preset sequences are completed, measurement results are

Strany 59

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-33 Figure 5-21 [Stand-by] Summary Simplified ScreenFigure 5-22 [Stand-by] Summary Detailed

Strany 60

5-34 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Start: Starts testing the mobile phone by Automatic Te

Strany 61

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-35 Softkey Menu 3• Simple: Displays a Pass/Fail result of whole measurement in the middle o

Strany 62

5-36 N9360A Multi UE Tester GSM User Manual5 Screen Reference The information from the mobile phone as Table 5-8 is displayed in the screen field.Mess

Strany 63

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-37 Step 3Either a measurement result list or a graph with a measurement result list is disp

Strany 64

5-38 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves a

Strany 65

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-39 Figure 5-25 [Stand-by] Burst Timing/ Power Ramp Screen

Strany 66

5-40 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves a

Strany 67

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-41 Screen FieldThe measurement results are shown in the screen field.Phase Error/ Frequency

Strany 68

16 N9360A Multi UE Tester GSM User Manual Table 5-74. [Configuration] Screen Input Field 5-170Table 5-75. Setting Combination for Automatic Test

Strany 69

5-42 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves a

Strany 70

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-43 Sensitivity/ RX Quality/ RX LevelThis function measures and analyzes the received sensit

Strany 71 - Handover

5-44 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves a

Strany 72

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-45 Manual Test (GSM Mode)Feature of Manual Test• All test items are executed while the mobi

Strany 73

5-46 N9360A Multi UE Tester GSM User Manual5 Screen Reference Test S I MInsert the Test SIM provided by Agilent in the mobile phone before performing

Strany 74

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-47 •The Sing mode setting provides single measurement in RF test.•The Cont mode setting pro

Strany 75 - button on

5-48 N9360A Multi UE Tester GSM User Manual5 Screen Reference The following measurement items are displayed in groups in the table. When a group of me

Strany 76

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-49 The information from the mobile phone as Table 5-15 is displayed on the left side of the

Strany 77

5-50 N9360A Multi UE Tester GSM User Manual5 Screen Reference Message FieldThe following message is displayed in the message field on the [Stand-by] s

Strany 78 - Emergency Call

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-51 The following test result is shown in the test result field of the MS Call step.• P: Sho

Strany 79 - Figure 4-39 [Initial] Screen

1-1 Agilent Technologies1Legal InformationWarranty 1-2Technology Licenses 1-2Restricted Rights Legend 1-2Service And Support 1-3Agilent

Strany 80

5-52 N9360A Multi UE Tester GSM User Manual5 Screen Reference Figure 5-31 [Measuring] BS Call Connection Screen Figure 5-32 [Measuring] MS Call Connec

Strany 81

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-53 Softkey Menu FieldSoftkey Menu 1• Release: Executes call Release from the Tester.• Clear

Strany 82

5-54 N9360A Multi UE Tester GSM User Manual5 Screen Reference The information from the mobile phone as Table 5-17 is displayed on the left side of the

Strany 83

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-55 Message FieldThe following message is displayed in the message field on the Connection s

Strany 84

5-56 N9360A Multi UE Tester GSM User Manual5 Screen Reference Figure 5-33 [Measuring] BS Call Screen

Strany 85

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-57 Softkey Menu FieldSoftkey Menu• Trigger Sing/Cont: Selects the trigger mode from Sing (s

Strany 86

5-58 N9360A Multi UE Tester GSM User Manual5 Screen Reference Summary ScreenWhen the measurement is completed, a [Measuring] summary screen showing me

Strany 87

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-59 Softkey Menu FieldSoftkey Menu 1• Location Update: Executes the Location Update process

Strany 88

5-60 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file of

Strany 89

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-61 Graph/Value Screen Peak TX Power/ Burst Timing/ Power RampThe measured data are shown in

Strany 90

1-2 N9360A Multi UE Tester GSM User Manual1 Legal Information Legal InformationWarrantyThe material contained in this document is provided “as is,” an

Strany 91

5-62 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR CO

Strany 92

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-63 •The Sing mode setting provides single measurement.•The Cont mode setting provides conti

Strany 93

5-64 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement results are shown in the screen field.BCCH *Sets the broadcast control c

Strany 94

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-65 Phase Error/ Frequency ErrorThe RMS and Peak Phase Error and Frequency Error are shown a

Strany 95

5-66 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR CO

Strany 96

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-67 Screen FieldSet the input fields of the following parameters to execute a new test.The m

Strany 97

5-68 N9360A Multi UE Tester GSM User Manual5 Screen Reference Sensitivity/ RX Quality/ RX LevelThe measured data for BER, FER, RX Quality, and RX Leve

Strany 98

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-69 Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves a

Strany 99

5-70 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement results are shown in the screen field.BCCH *Sets the broadcast control c

Strany 100 - 4 Operating Procedures

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-71 Spectrum MonitorThe RF spectrum of the traffic channel can be measured by Spectrum Monit

Strany 101 - Operating Procedures 4

Legal Information 1N9360A Multi UE Tester GSM User Manual 1-3 Service And SupportAny adjustment, maintenance, or repair of this product must be perfor

Strany 102

5-72 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR CO

Strany 103

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-73 •To terminate continuous measurement on the [Measuring] screen, change the trigger mode

Strany 104

5-74 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement results as Table 5-25 is displayed:TCH *Sets a traffic channel number.Th

Strany 105

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-75 Message FieldThe following message is displayed in the message field:Press the desired s

Strany 106

5-76 N9360A Multi UE Tester GSM User Manual5 Screen Reference • Return: Returns to the [Stand-by] screen.Softkey Menu 2• Print Screen: Prints a hardco

Strany 107

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-77 The data and the message from/to the mobile phone are shown in this field. Message Field

Strany 108

5-78 N9360A Multi UE Tester GSM User Manual5 Screen Reference Explanation• SMSMO: Send a message from the mobile phone, and then the message is displa

Strany 109 - Sing, single

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-79 Slot Configuration and Measurement SlotThe combination of the slot configuration and the

Strany 110

5-80 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Clear Status: Clears Pass/Fail results at signaling st

Strany 111

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-81 Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file of

Strany 112

Notices© Agilent Technologies, Inc. 2006No part of this manual may be repro-duced in any form or by any means (including electronic storage and retrie

Strany 113

1-4 N9360A Multi UE Tester GSM User Manual1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK

Strany 114

5-82 N9360A Multi UE Tester GSM User Manual5 Screen Reference The following measurement items are displayed in groups in the table. When a group of me

Strany 115

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-83 The information from the mobile phone is displayed on the left side of the screen:The RF

Strany 116

5-84 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• End: Starts the detach process.• Clear Status: Clears

Strany 117 - Ending a Test

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-85 Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file of

Strany 118

5-86 N9360A Multi UE Tester GSM User Manual5 Screen Reference The information from the mobile phone is displayed on the left side of the screen.Messag

Strany 119 - Screen Reference

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-87 Connected ScreenWhen measurement starts, the [Measuring] connected screen as Figure 5-45

Strany 120 - Screen Flow Chart

5-88 N9360A Multi UE Tester GSM User Manual5 Screen Reference Summary ScreenAfter completion of the measurement in the Connected step, the disconnect

Strany 121 - Configuration

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-89 Softkey Menu FieldSoftkey Menu 1• Clear Status: Clears Pass/Fail results at signaling st

Strany 122 - 5 Screen Reference

5-90 N9360A Multi UE Tester GSM User Manual5 Screen Reference Step 1Place the cursor at one of the test items by rotating the CURSOR CONTROL knob.Step

Strany 123 - Configuration Screen

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-91 Figure 5-47[Measuring] Peak TX Power/ Burst Timing/ Power Ramp ScreenFigure 5-48[Measuri

Strany 124

2-1 Agilent Technologies2Caution and Safety RequirementsSafety Summary 2-2Safety Notices 2-2Warning Label 2-2General 2-3When Operating T

Strany 125

5-92 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR CO

Strany 126

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-93 Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file of

Strany 127 - Option Installation/Backup

5-94 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement results are shown in the screen field.The RMS and Peak Phase Error and F

Strany 128 - Firmware Update Screen

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-95 Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR CO

Strany 129 - Screen Reference 5

5-96 N9360A Multi UE Tester GSM User Manual5 Screen Reference •To terminate continuous measurement on the [Measuring] screen, change the trigger mode

Strany 130 - Initial Screen

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-97 The measurement items are shown in the screen field.Sensitivity in BLERThe measured data

Strany 131

5-98 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves a

Strany 132

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-99 •This softkey is effective only for changing the trigger mode on the [Stand-by] screen.•

Strany 133 - Return to Menu Screen

5-100 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement result is displayed in the screen field.Spectrum MonitorThe RF spectrum

Strany 134 - Automatic Test

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-101 Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 135

2-2 N9360A Multi UE Tester GSM User Manual2 Caution and Safety Requirements Safety InformationSafety SummaryThe following general safety precautions m

Strany 136

5-102 N9360A Multi UE Tester GSM User Manual5 Screen Reference •To terminate continuous measurement on the [Measuring] screen, change the trigger mode

Strany 137

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-103 The measurement results are shown in the screen field:PDTCH *Sets a packet data traffic

Strany 138

5-104 N9360A Multi UE Tester GSM User Manual5 Screen Reference Manual Test (EGPRS Mode)Description of EGPRS SystemThe Enhanced General Packet Radio Se

Strany 139

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-105 Test S I MInsert the Test SIM provided by Agilent in the mobile phone before performin

Strany 140 - Measuring Screen

5-106 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Clear Status: Clears Pass/Fail results at signaling s

Strany 141

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-107 Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file o

Strany 142

5-108 N9360A Multi UE Tester GSM User Manual5 Screen Reference The following measurement items are displayed in groups in the table. When a group of m

Strany 143 - Measuring Talk Screen

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-109 The information from the mobile phone is displayed on the left side of the screen:The R

Strany 144

5-110 N9360A Multi UE Tester GSM User Manual5 Screen Reference Attached ScreenAfter completion of the attaching process, the [Measuring] screen as Fig

Strany 145

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-111 • More (1 of 2): Displays the softkey menu 2.Softkey Menu 2• Print Screen: Prints a har

Strany 146 - Aborted screen

Caution and Safety Requirements 2N9360A Multi UE Tester GSM User Manual 2-3 GeneralWhen Operating The TesterWARNINGThe protection provided by the N936

Strany 147

5-112 N9360A Multi UE Tester GSM User Manual5 Screen Reference The information from the mobile phone is displayed on the left side of the screen.Messa

Strany 148 - Sequence 2 Screen

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-113 ExplanationThe Connect process starts and measurement is executed with the following wa

Strany 149

5-114 N9360A Multi UE Tester GSM User Manual5 Screen Reference •The Sing mode setting provides single measurement. When the trigger mode is changed fr

Strany 150 - Summary Screen

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-115 Softkey Menu FieldSoftkey Menu 1• Clear Status: Clears Pass/Fail results at signaling s

Strany 151

5-116 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file o

Strany 152

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-117 Graph/Value Screen Peak TX Power/ Burst Timing/ Power RampThe measured data are shown i

Strany 153

5-118 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 154

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-119 •The Sing mode setting provides single measurement.•The Cont mode setting provides cont

Strany 155 - Graph/Value Screen

5-120 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement results are shown in the screen field.BCCH *Sets the broadcast control

Strany 156

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-121 Phase Error/ Frequency ErrorThe RMS and Peak Phase Error and Frequency Error are shown

Strany 157

2-4 N9360A Multi UE Tester GSM User Manual2 Caution and Safety Requirements THIS PAGE IS INTENTIONALLY LEFT BLANK

Strany 158

5-122 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 159

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-123 Screen FieldSet the input fields of the following parameters to execute a new test.The

Strany 160

5-124 N9360A Multi UE Tester GSM User Manual5 Screen Reference EVMThe RMS, Peak, 95 %, Frequency Error, and Origin Offset are shown along with the mar

Strany 161

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-125 Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 162

5-126 N9360A Multi UE Tester GSM User Manual5 Screen Reference •To terminate continuous measurement on the [Measuring] screen, change the trigger mode

Strany 163 - Manual Test (GSM Mode)

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-127 The measurement items are shown in the screen field.PDTCH *Sets a packet data traffic c

Strany 164 - Stand-by Screen

5-128 N9360A Multi UE Tester GSM User Manual5 Screen Reference Message FieldThe following message is displayed in the message field on the [Measuring]

Strany 165

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-129 • Trigger Sing/Cont: Selects the trigger mode from Sing (single) and Cont (continuous).

Strany 166

5-130 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement result is displayed in the screen field.Output RF Spectrum (ORFS)The po

Strany 167

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-131 Softkey Menu FieldSoftkey Menu 1• Trigger Sing/Cont: Selects the trigger mode from Sing

Strany 168

3-1 Agilent Technologies3OverviewFunctions 3-2Features 3-4Standard Configuration 3-5Accessories 3-6This chapter concisely describes the

Strany 169 - Connection Screen

5-132 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file o

Strany 170

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-133 The measurement result is displayed in the screen field.Spectrum MonitorThe RF spectrum

Strany 171

5-134 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 172

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-135 •To terminate continuous measurement on the [Measuring] screen, change the trigger mode

Strany 173

5-136 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement results are shown in the screen field:PDTCH *Sets a packet data traffic

Strany 174

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-137 TX AnalyzerFeature of TX Analyzer• All test items are measured without signaling proces

Strany 175

5-138 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Spectrum Monitor: Displays the Spectrum Monitor scree

Strany 176

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-139 Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file o

Strany 177

5-140 N9360A Multi UE Tester GSM User Manual5 Screen Reference The following measurement items are displayed in groups in the table. When a group of m

Strany 178

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-141 Message FieldThe following message is displayed in the message field on the [Stand-by]

Strany 179

3-2 N9360A Multi UE Tester GSM User Manual3 Overview GSM Option is a software for N9360A Multi UE Tester which supports the signaling tests and the RF

Strany 180

5-142 N9360A Multi UE Tester GSM User Manual5 Screen Reference Measuring ScreenWhen measurement starts, the [Measuring] screen as Figure 5-64 is displ

Strany 181

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-143 Message FieldThe following message is displayed in the message screen on the [Measuring

Strany 182

5-144 N9360A Multi UE Tester GSM User Manual5 Screen Reference • RF Output On/Off: Selects the RF power output from On and Off. RF On is displayed at

Strany 183

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-145 Step 3Either a measurement result list or a graph with a measurement result list is dis

Strany 184

5-146 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 185 - Screen Field

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-147 •The Sing mode setting provides single measurement.•When the trigger mode is changed fr

Strany 186

5-148 N9360A Multi UE Tester GSM User Manual5 Screen Reference RFCH *Sets the broadcast control channel number.The allowable range is as follows:GSM85

Strany 187

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-149 The measurement results are shown in the screen field.Phase Error/ Frequency ErrorThe R

Strany 188

5-150 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 189

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-151 When the trigger mode is changed from Cont to Sing, the measurement is terminated.• Tri

Strany 190

Overview 3N9360A Multi UE Tester GSM User Manual 3-3 AttachConnectDisconnectCoding scheme: CS1, CS2, CS3, CS4 Multi slot: 1×1, 2×1, 2×2, 3×1, 3×2, 4×1

Strany 191

5-152 N9360A Multi UE Tester GSM User Manual5 Screen Reference Modulation • Selects one of the following modulation modes:• GMSK:BCCH: Sets the data

Strany 192

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-153 The measurement items are shown in the screen field.EVMThe RMS, Peak, 95 %, Frequency E

Strany 193 - SMS Screen

5-154 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 194

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-155 •To terminate continuous measurement on the [Measuring] screen, change the trigger mode

Strany 195

5-156 N9360A Multi UE Tester GSM User Manual5 Screen Reference Modulation Selects one of the following modulation modes:•GMSK:BCCH: Sets the data of B

Strany 196 - Manual Test (GPRS Mode)

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-157 The measurement items are shown in the screen field.Output RF Spectrum (ORFS)The power

Strany 197

5-158 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Trigger Sing/Cont: Selects the trigger mode from Sing

Strany 198

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-159 Softkey Menu 2• Print Screen: Prints a hardcopy of the screen or saves a graphic file o

Strany 199 - • Sensitivity/BLER

5-160 N9360A Multi UE Tester GSM User Manual5 Screen Reference The measurement result is displayed in the screen field.Spectrum MonitorThe RF spectrum

Strany 200

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-161 Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 201 - Attached Screen

3-4 N9360A Multi UE Tester GSM User Manual3 Overview FeaturesEasy-to-operate Automatic TestThe tests from call processes to the radio performance test

Strany 202

5-162 N9360A Multi UE Tester GSM User Manual5 Screen Reference •The Cont mode setting provides continuous measurement.When the trigger mode is changed

Strany 203

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-163 Softkey Menu FieldSoftkey Menu 1• Knob Cur/Marker: Selects the function of the CURSOR C

Strany 204

5-164 N9360A Multi UE Tester GSM User Manual5 Screen Reference •The Cont mode setting provides continuous measurement.When the trigger mode is changed

Strany 205 - Connected Screen

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-165 Table 5-72 [TX Analyzer] Spectrum Monitor Screen Input FieldInput Field DescriptionProc

Strany 206

5-166 N9360A Multi UE Tester GSM User Manual5 Screen Reference Signal GeneratorFeature of Signal GeneratorThe Tester is capable to generate RF signal

Strany 207

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-167 Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves

Strany 208

5-168 N9360A Multi UE Tester GSM User Manual5 Screen Reference ConfigurationFeature of ConfigurationIn this mode, there are four major functions as fo

Strany 209

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-169 Configuration ScreenWhen the Configuration softkey is pressed on the [Initial] screen,

Strany 210

5-170 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Te st S eque nce : Go to the [Configuration: Test Seq

Strany 211

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-171 Reference Displays the current reference signal source. The reference signal source can

Strany 212

Overview 3N9360A Multi UE Tester GSM User Manual 3-5 External Control Function (Remote Control)Remote control is available using Ethernet, GP-IB or Se

Strany 213

5-172 N9360A Multi UE Tester GSM User Manual5 Screen Reference Also, the following information is shown in the screen field:• MAC Address• Serial No.•

Strany 214

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-173 The attenuation values set on the [Configuration] screen are used for compensating the

Strany 215

5-174 N9360A Multi UE Tester GSM User Manual5 Screen Reference • For Location Update:Select Lu1 to execute MS Power On Location Update, Lu2 to execute

Strany 216

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-175 The following measurement items need to be set to Run to execute a Pass or Fail test or

Strany 217

5-176 N9360A Multi UE Tester GSM User Manual5 Screen Reference Configuration: Test Condition ScreenWhen the Test Condition softkey on the [Configurati

Strany 218

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-177 Figure 5-76 [Configuration: Test Condition] (GSM Mode) Screen

Strany 219

5-178 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu• Print Screen: Prints a hardcopy of the screen or saves

Strany 220

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-179 Table 5-78 [Configuration: Test Sequence] Screen Input FieldInput Field DescriptionRadi

Strany 221

5-180 N9360A Multi UE Tester GSM User Manual5 Screen Reference BS Level ‡ Sets the RF output level of the Tester except for the Sensitivity test. The

Strany 222 - Manual Test (EGPRS Mode)

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-181 Setting Measurement Limits for Measurement ItemsThe LO Limit and HI Limit values for th

Strany 223

1N9360A Multi UE Tester GSM User Manual 1-3 PrefaceThank-you for purchasing the Agilent N9360A. GSM (Global System for Mobile Communication). This is

Strany 224

3-6 N9360A Multi UE Tester GSM User Manual3 Overview AccessoriesTable 3-3 shows the accessories of the Tester. For the specification of the accessorie

Strany 225

5-182 N9360A Multi UE Tester GSM User Manual5 Screen Reference Table 5-79 Configuration: Test Condition Measurement ItemMeasurement Item DescriptionPe

Strany 226

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-183 Configuration: File ManagementWhen the File Management softkey is pressed on the [Confi

Strany 227

5-184 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu FieldSoftkey Menu 1• Save: Saves a file including all test parameters whic

Strany 228

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-185 Step 2Insert a USB memory device into the USB Connector on the front panel of the Teste

Strany 229

5-186 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu• Save Now: Saves the parameter file in the HDD or USB memory device. Press

Strany 230

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-187 Step 7Selects alphanumeric characters and other symbols by rotating and pressing the CU

Strany 231

5-188 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey Menu• Done: Determines the words entered.• Cancel: Cancels editing.• Caps On/Of

Strany 232

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-189 Step 9Move the cursor to the Comment field and press it once. The rectangular cursor is

Strany 233

5-190 N9360A Multi UE Tester GSM User Manual5 Screen Reference Step 11If saving is properly done, the new filename should be displayed in the filename

Strany 234

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-191 Step 5Press the Recall softkey, and then the Filename, Date, Time and Comment fields ar

Strany 235

4-1 Agilent Technologies4Operating ProceduresTest F l ow 4-2Preparation for Each Test 4-3Connection 4-4Test P r oced ure 4-5Ending a Tes

Strany 236

5-192 N9360A Multi UE Tester GSM User Manual5 Screen Reference Softkey• Yes : Executes restoring the parameter file.• No: Cancels recalling the parame

Strany 237

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-193 Deleting a Test Setup FileDelete one of the parameter files with the following procedur

Strany 238

5-194 N9360A Multi UE Tester GSM User Manual5 Screen Reference Step 4Move the cursor to the file number of which you want to delete the test parameter

Strany 239

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-195 Softkey• Yes :Executes deleting the parameter file.• No:Cancels deleting the parameter

Strany 240

5-196 N9360A Multi UE Tester GSM User Manual5 Screen Reference Replacing a Test Setup FileReplace the parameter files in the HDD with the data in the

Strany 241

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-197 • HDD is underlined: The data saved in the HDD is copied to the USB.• USB is underlined

Strany 242

5-198 N9360A Multi UE Tester GSM User Manual5 Screen Reference Figure 5-91 [Configuration: File Management] Replace-2 Screen

Strany 243

Screen Reference 5N9360A Multi UE Tester GSM User Manual 5-199 Softkey Menu• Replace Now: Starts Replace operation.• Cancel: Cancels replacing and ret

Strany 244

5-200 N9360A Multi UE Tester GSM User Manual5 Screen Reference THIS PAGE IS INTENTIONALLY LEFT BLANK

Strany 245

6-1 Agilent Technologies6TroubleshootingItem to be checked 6-2Error Information 6-6This chapter describes how to solve problems and explains a

Strany 246

4-2 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Test Flo wThis section describes a test flow to check the mobile phone with the N936

Strany 247

6-2 N9360A Multi UE Tester GSM User Manual6 Troubleshooting Item to be checkedThe symptoms listed below may not be caused by Tester failure.Check the

Strany 248

Troubleshooting 6N9360A Multi UE Tester GSM User Manual 6-3 —— is displayed at the measurement of Sensitivity BER.Is the BER BS level or the Sens BS l

Strany 249

6-4 N9360A Multi UE Tester GSM User Manual6 Troubleshooting Attach process fails in GPRS mode.Does the mobile phone require Detach process?Some kinds

Strany 250

Troubleshooting 6N9360A Multi UE Tester GSM User Manual 6-5 TSC not found is displayed on the Graph/Value screen.Does the signal inputted to the Teste

Strany 251 - PWR CNTL

6-6 N9360A Multi UE Tester GSM User Manual6 Troubleshooting Error InformationError ScreenFigure 6-1 is an example of the screens that are displayed wh

Strany 252

Troubleshooting 6N9360A Multi UE Tester GSM User Manual 6-7 Error Codes for Error ScreensTable 6-3 and Table 6-4 list error codes for [Error] screens.

Strany 253

6-8 N9360A Multi UE Tester GSM User Manual6 Troubleshooting 1000 Unit reboot is detected. A firmware error occurred. Reboot the Tester.1001 Unit fatal

Strany 254

7-1 Agilent Technologies7Performance and SpecificationsMeasurement Performance 7-2This chapter lists the performance and specifications of the N9

Strany 255 - TX Analyzer

7-2 N9360A Multi UE Tester GSM User Manual7 Performance and Specifications Measurement PerformancePeak TX Power Power RampFrequency ErrorTable 7-1 Pea

Strany 256

Performance and Specifications 7N9360A Multi UE Tester GSM User Manual 7-3 Phase Error (GMSK)Burst TimingBER, FER/BLERAccuracy ≤±(10 + Reference signa

Strany 257

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-3 Preparation for Each TestThe following procedures are required before starting each t

Strany 258

7-4 N9360A Multi UE Tester GSM User Manual7 Performance and Specifications RX QualityRX LevelActual Timing AdvanceSync range BER(PN9fix) 0.00 to 99.99

Strany 259 - . are shown

Performance and Specifications 7N9360A Multi UE Tester GSM User Manual 7-5 Spectrum MonitorFrequency OffsetAM ModulationEVM (8-PSK, Option G03)Table 7

Strany 260

7-6 N9360A Multi UE Tester GSM User Manual7 Performance and Specifications Origin offset suppression (8-PSK, Option G03)Output RF Spectrum (8-PSK, Opt

Strany 261

8-1 Agilent Technologies8Appendix A Input Fields and Allowable Choices or RangesHere is a table of the input fields and allowable choices or ranges

Strany 262

8-2 N9360A Multi UE Tester GSM User Manual8 Appendix A Input Fields and Allowable Choices or Ranges Table 8-1 Input Fields and Allowable Choices or Ra

Strany 263

Appendix A Input Fields and Allowable Choices or Ranges 8N9360A Multi UE Tester GSM User Manual 8-3 Manual Test (GSM)Test Item On | OffProcedure Filen

Strany 264

8-4 N9360A Multi UE Tester GSM User Manual8 Appendix A Input Fields and Allowable Choices or Ranges Manual Test (GPRS)Measurement Item On | OffProcedu

Strany 265

Appendix A Input Fields and Allowable Choices or Ranges 8N9360A Multi UE Tester GSM User Manual 8-5 Manual Test (EGPRS)Measurement Item On | OffProced

Strany 266

8-6 N9360A Multi UE Tester GSM User Manual8 Appendix A Input Fields and Allowable Choices or Ranges TX Analyzer Measurement Item On | OffProcedure Fil

Strany 267

Appendix A Input Fields and Allowable Choices or Ranges 8N9360A Multi UE Tester GSM User Manual 8-7 Configuration (Top Menu)Reference Internal | Exter

Strany 268

4-4 N9360A Multi UE Tester GSM User Manual4 Operating Procedures ConnectionConnecting a Mobile PhoneConnect a mobile phone to the Tester using any of

Strany 269

8-8 N9360A Multi UE Tester GSM User Manual8 Appendix A Input Fields and Allowable Choices or Ranges Configuration Procedure FilenamePanel Key Lock | U

Strany 270

Appendix A Input Fields and Allowable Choices or Ranges 8N9360A Multi UE Tester GSM User Manual 8-9 Test Sequence Sequence No 1 GSM850 | GSM900 | DCS1

Strany 271

8-10 N9360A Multi UE Tester GSM User Manual8 Appendix A Input Fields and Allowable Choices or Ranges Test Condition Radio System GSM850 | GSM900 | DCS

Strany 272

Appendix A Input Fields and Allowable Choices or Ranges 8N9360A Multi UE Tester GSM User Manual 8-11 GSM ModeBER BS Level –110.0 to –50.0 dBmBER Frame

Strany 273

8-12 N9360A Multi UE Tester GSM User Manual8 Appendix A Input Fields and Allowable Choices or Ranges Coding SchemeMCS1 to MCS9Puncturing SchemeP1 to P

Strany 274

9-1 Agilent Technologies9Appendix B General Information in the GSM SystemThe GSM System 9-2For your reference, some major information in the GSM

Strany 275

9-2 N9360A Multi UE Tester GSM User Manual9 Appendix B General Information in the GSM System The GSM SystemA GSM mobile phone transmits speech as burs

Strany 276

Appendix B General Information in the GSM System 9N9360A Multi UE Tester GSM User Manual 9-3 Power Control LevelsThe power control levels, RF power le

Strany 277

9-4 N9360A Multi UE Tester GSM User Manual9 Appendix B General Information in the GSM System RX LevelThe RX levels are defined as follows:Table 9-4 RX

Strany 278

Appendix B General Information in the GSM System 9N9360A Multi UE Tester GSM User Manual 9-5 RX QualityThe RX quality is defined as follows:Limits for

Strany 279

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-5 2 USB Memory DeviceTo save graphic files of screen in a USB memory device, connect th

Strany 280

9-6 N9360A Multi UE Tester GSM User Manual9 Appendix B General Information in the GSM System THIS PAGE IS INTENTIONALLY LEFT BLANK

Strany 281

10-1 Agilent Technologies10Appendix C CAU-17 Antenna CouplerIntroduction 10-2Specifications 10-2Operating the Antenna Coupler 10-3This chap

Strany 282

10-2 N9360A Multi UE Tester GSM User Manual10 Appendix C CAU-17 Antenna Coupler IntroductionAgilent Technologies CAU-17 Antenna Coupler enables you to

Strany 283

Appendix C CAU-17 Antenna Coupler 10N9360A Multi UE Tester GSM User Manual 10-3 Length: approximately 42 mmOperating the Antenna Coupler1 If the anten

Strany 284 - Signal Generator

10-4 N9360A Multi UE Tester GSM User Manual10 Appendix C CAU-17 Antenna Coupler 4 Set the attenuation (loss) values on the [Configuration] screen. Ref

Strany 285 - On and Off. RF

4-6 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Depending on functions and test situations, there are several types of screen. Figure

Strany 286 - Configuration

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-7 Test Parameters, Test Items and Allowable RangesDepending on the function modes, the

Strany 287

4-8 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 1Rotate the CURSOR CONTROL knob clockwise to move the cursor downward or right,

Strany 288

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-9 For numeric input fields such as channel numbers and relevancies of amplitude, you ca

Strany 289

1-4 N9360A Multi UE Tester GSM User Manual1 THIS PAGE IS INTENTIONALLY LEFT BLANK

Strany 290

4-10 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 3Set a numeric value in the input field with the CURSOR CONTROL knob.Step 4Pres

Strany 291

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-11 Step 6The memory softkey menu returns to the state in Step 2 showing the value newly

Strany 292

4-12 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 3Press Memory 1, Memory 2, Memory 3 or Memory 4 softkey to enter the stored val

Strany 293

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-13 Changing Magnification SoftkeyPress the CURSOR CONTROL knob to select a numeric inpu

Strany 294

4-14 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 1Press the GSM softkey to select the GSM system. The [Initial] screen for GSM i

Strany 295

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-15 Selection of the Function Mode on the Initial ScreenThe Tester executes its initiali

Strany 296

4-16 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Softkey Menu FieldSoftkey menuAutomatic Test: Starts the Automatic Test. Refer to Te

Strany 297

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-17 CorrectionActual Input/Output Level and Correction1 Actual Output Level and Correcti

Strany 298

4-18 N9360A Multi UE Tester GSM User Manual4 Operating Procedures LossRfIn = Setting value at the LOSS/RF In field on the [Configuration] screen.3 Act

Strany 299

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-19 LossRfIn = Setting value at the LOSS/RF IN field on the [Configuration] screen.AttIn

Strany 300

N9360A Multi UE Tester GSM User Manual 5 ContentsPreface 1-3Notation 1-3Notices 1-3Trademarks 1-31 Legal InformationLegal Informat

Strany 301 - Measurement Item Description

4-20 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 3Set the Loss field to On with the CURSOR CONTROL knob.Step 4Enter the appropri

Strany 302 - Saving a Test Setup File

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-21 This section describes correction for RF test results in Automatic Test. Each traffi

Strany 303 - USB, is underlined

4-22 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 3Enter the appropriate attenuation values, depending on the traffic channel, in

Strany 304

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-23 Step 1Turn on the Tester and select the GSM system on the [Top Menu] screen. Refer t

Strany 305

4-24 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 4Press the Te s t S eque n c e softkey to display the [Configuration: Test Se

Strany 306

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-25 Step 5Set GSM900 and DCS1800 in Radio System 1 and 2, respectively, and set other fi

Strany 307

4-26 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 8Press the Return and then the Te st Co n d i t i on softkey to display the [Co

Strany 308 - Recalling a Test Setup File

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-27 Step 12Press the Return softkey twice and then the Automatic Test softkey to start A

Strany 309

4-28 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 14Press the Start softkey to start a test. A screen status changes from Stand-b

Strany 310

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-29 Step 18As each step is running in the test flow, its corresponding test item field i

Strany 311 - Deleting a Test Setup File

6 N9360A Multi UE Tester GSM User Manual Automatic Test 5-16Manual Test (GSM Mode) 5-45Manual Test (GPRS Mode) 5-78Manual Test (EGPRS M

Strany 312

4-30 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 23If a printer is available, print the test results. Press the More (1 of 2), a

Strany 313

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-31 Step 26Press the Return softkey to return to the previous screen. The Graph/Value sc

Strany 314 - Replacing a Test Setup File

4-32 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 1Turn on the Tester and select the GSM system on the [Top Menu] screen. Refer t

Strany 315

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-33 Step 4Press the Test Condition softkey to display the [Configuration: Test Condition

Strany 316

4-34 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 5Set the input fields with the CURSOR CONTROL knob.Step 6Set the appropriate te

Strany 317

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-35 Step 8Turn the mobile phone on and wait for it to camp on, and P is shown at the Loc

Strany 318

4-36 N9360A Multi UE Tester GSM User Manual4 Operating Procedures • If the trigger mode is set to Cont (continuous), continuous measurement starts imm

Strany 319 - Troubleshooting

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-37 Step 12Select a group of measurement items with the CURSOR CONTROL knob to display t

Strany 320 - Item to be checked

4-38 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 13Press a softkey as needed.Knob Cur/Marker: Selects the cursor or the marker.M

Strany 321 - Table 6-1 Item to be checked

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-39 More (1 of 2): Displays the softkey menu 2.Return: Returns to the previous screen.Pr

Strany 322

N9360A Multi UE Tester GSM User Manual 7 List Of Figures4 Operating ProceduresFigure 4-1. Test Flow 4-2Figure 4-2. Typical Test Setup of the Test

Strany 323

4-40 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 15Press the Trigger softkey to measure spectrum in single mode or the Trigger S

Strany 324 - Error Information

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-41 HandoverStep 1Turn on the Tester and select the GSM system on the [Top Menu] screen.

Strany 325

4-42 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 3Press the Config softkey on the [Initial] screen to display the [Configuration

Strany 326

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-43 Step 4Press the Test Condition softkey to display the [Configuration: Test Condition

Strany 327

4-44 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 5Set the input fields with the CURSOR CONTROL knob.Step 6Set the appropriate te

Strany 328 - Measurement Performance

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-45 Step 8Turn the mobile phone on and P is shown at the Location Update step.Step 9Star

Strany 329 - BER, FER/BLER

4-46 N9360A Multi UE Tester GSM User Manual4 Operating Procedures • If the trigger mode is set to Cont (continuous), continuous measurement starts imm

Strany 330 - Actual Timing Advance

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-47 Step 12Change the channel with the following operation.Move the cursor to TCH input

Strany 331 - AM Modulation

4-48 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Emergency CallStep 1Turn on the Tester and select the GSM system on the [Top Menu] s

Strany 332 - Table 7-13 EVM (8-PSK)

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-49 Step 3Press the Config softkey on the [Initial] screen to display the [Configuration

Strany 333 - Choices or Ranges

8 N9360A Multi UE Tester GSM User Manual Figure 4-40. [Configuration] Screen 4-50Figure 4-41. [Configuration: Test Condition] Screen 4-51Fig

Strany 334

4-50 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 4Press the Test Condition softkey to display the [Configuration: Test Condition

Strany 335

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-51 Step 5Set the input fields with the CURSOR CONTROL knob.Step 6Set the appropriate te

Strany 336

4-52 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 8Turn the mobile phone on and P is shown at the Location Update step.Step 9Dial

Strany 337

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-53 • If the trigger mode is set to Cont (continuous), continuous measurement starts imm

Strany 338 - –100.0 to +100.0

4-54 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 12Press the Release softkey to start BS release, or press the On Hook button on

Strany 339

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-55 Testing a Mobile Phone by Manual Test (GPRS Mode)This section describes the operatio

Strany 340

4-56 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 3Press the Config softkey on the [Initial] screen to display the [Configuration

Strany 341

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-57 Step 4Press the Test Condition softkey to display the [Configuration: Test Condition

Strany 342

4-58 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 5Set the input fields with the CURSOR CONTROL knob. Set the GSM Mode to GPRS.St

Strany 343

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-59 Step 8Check the difference in the test flow, the parameters for slot configuration,

Strany 344

N9360A Multi UE Tester GSM User Manual 9 5 Screen ReferenceFigure 5-1. Screen Flow Chart 5-2Figure 5-2. Selectable Systems 5-3Figure 5-3. [T

Strany 345 - GSM System

4-60 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 12When the attached process is succeeded, the Tester waits for the trigger.• Wh

Strany 346 - The GSM System

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-61 Step 13During continuous measurement, change the trigger mode from Cont to Sing to t

Strany 347 - Power Control Levels

4-62 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 15Select a group of measurement items with the CURSOR CONTROL knob to display t

Strany 348

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-63 Step 16Press a softkey as needed.Knob Cur/Marker: Selects the cursor or the marker.M

Strany 349 - Limits for Frequency Error

4-64 N9360A Multi UE Tester GSM User Manual4 Operating Procedures More (1 of 2): Displays the softkey menu 2.Return: Returns to the previous screen.Pr

Strany 350

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-65 Step 18Press the Trigger softkey to measure spectrum in single mode, or the Trigger

Strany 351

4-66 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 1Turn on the Tester and select the GSM system on the [Top Menu] screen. Refer t

Strany 352 - Specifications

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-67 Step 3Press the Config softkey on the [Initial] screen to display the [Configuration

Strany 353 - Operating the Antenna Coupler

4-68 N9360A Multi UE Tester GSM User Manual4 Operating Procedures Step 5Set the input fields with the CURSOR CONTROL knob. Set the GSM Mode to EGPRS.S

Strany 354

Operating Procedures 4N9360A Multi UE Tester GSM User Manual 4-69 Step 8Check the difference in the test flow, the parameters for slot configuration,

Komentáře k této Příručce