MXIbus-4 : Set the VXI-MXI Module’s Logical Address
Set the logical address on your VXI-MXI modules by using the following
steps:
1. Locate the logical address switch, an 8-bit DIP switch at U64. See
Figure 3-11.
2. Determine your system configuration from the following figures:
2-Frame System - Command Module (Figure 3-12)
3-Frame System - Command Module (Figure 3-13)
2-Frame - VXI-MXI (Figure 3-14)
3-Frame - VXI-MXI (Figure 3-15)
2-Frame - RadiSys EPC-7 (Figure 3-16)
3-Frame - RadiSys EPC-7 (Figure 3-17)
2-Frame - Agilent V743 (Figure 3-18)
3-Frame - Agilent V743 (Figure 3-19)
3. Set the VXI-MXI logical address recommended in the above
figures. Table 3-2 shows switch positions for some of the most
commonly used VXI-MXI logical address.
NOTE Since the VXI-MXI does not have VXIbus resource manager capability, do
not set the logical address for the VXI-MXI to 0.
3-10 Set Up the System for Multiple Mainframes C-Size Configuration Guide