Agilent Technologies FS2010 Servisní příručka Strana 54

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 396
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 53
46 Agilent Signal Generators Programming Guide
Using IO Interfaces
Using LAN
Figure 2-6 Telnet Window (Windows 2000)
Using Telnet On Windows 2000
1. On your PC, click Start > Run.
2. Type telnet in the run text box, then click the OK button. The Telnet connection screen will be
displayed. See Figure 2- 7 on page 47 (Windows 2000).
3. Type open at the prompt and then press the Enter key. The prompt will change to (to).
4. At the (to) prompt, enter the signal generator’s IP address followed by a space and 5023, which
is the Telnet port associated with the signal generator.
5. At the SCPI> prompt, enter SCPI commands. Refer to commands shown in Figure 2- 6 on
page 46.
6. To escape from the SCPI> session type Ctrl-].
7. T ype quit at the prompt to end the Telnet session.