90 U2761A User’s Guide
2 Features and Functions
Set Triggering Using SCPI Commands
Example 1
-> *CLS; *RST //To reset the U2761A to
default power-on state,
this command can be
ignored if this operation
is not required.
-> FUNC SIN //Sets the carrier waveform
to Sine wave.
-> VOLT 5 VPP //Sets the output amplitude
to 5 Vpp.
-> VOLT:OFFS 0 //Sets the output offset to
0.
-> SWE:STAT ON //Enables frequency sweep.
-> FREQ:STAR 500 //Changes the start
frequency to 500 Hz.
-> FREQ:STOP 10000 //Changes the stop
frequency to 10 kHz.
-> SWE:SPAC LIN //Changes the sweep mode
to Linear.
-> SWE:TIME 2 //Changes the sweep time
to 2 s.
-> TRIG:SOUR IMM //Changes the sweep trigger
source to Internal.
-> OUTP:TRIG ON //Turns on the trigger
output.
-> OUTP:TRIG:SLOP POS //Outputs the trigger on a
rising edge.
-> OUTP ON //Turns on output.
Zobrazit stránku 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 122 123

Komentáře k této Příručce

Žádné komentáře

Case-mate Non manuels d'utilisation

La liste de Case-mate Non produits contient 1 manuels d'utilisation pour les modèles 1. Tous les guides d'utilisation en format pdf peuvent être téléchargés ou consultés en ligne.

Cliquez sur un alphabet ci-dessous pour faire défiler la liste complète des modèles commençant par cette lettre

Modèles Type de document
CM010092
Fiche technique   Case-mate iPhone 3G/3GS Battery Case, 6 pages