HFBR-0501 Environmental Test Data
MIL-STD-883 Units Units
Test Reference Test Conditions Tested Failed
Temperature 1010 200 cycles from -40 to +100°C, 1080 0
Cycle 15 minutes at extremes, 5 min. transfer.
[1]
HFBR-1521
200 cycles from -40 to +85°C, 1120 0
15 minutes at extremes, 5 min. transfer.
[1]
HFBR-2521
85/85 T
A
= 85°C, 85% relative humidity, 200 0
No bias, duration = 1,000 hours.
[1]
HFBR-1521
T
A
= 85°C, 85% relative humidity, 200 0
V
CC
= 5 volts, duration = 1,000 hours
[1]
HFBR-2521
Wave Soldering 3 cycles and washes.
[2]
80 0
HFBR-1521
3 cycles and washes.
[2]
80 0
HFBR-2521
Manual Soldering 260°C, 10 seconds 30 0
HFBR-1521
30 0
HFBR-2521
Gross Leak 1014, Cond. D 3 hours soak in UV fluorescent dye at 90 psi. 20 0
Resistance to 2015 Brush after solvent immersion. 30 0
Solvents
Vibration Variable 2007, 20 G min., 20 to 2000 Hz. 20 0
Frequency Condition B 4, 4 minute cycles each X, Y, Z.
Terminal Strength 2004 1 lb. tension, 8 oz. bending stress. 24 0
Mechanical Shock 2002, 5 blows each X1, X2, Y1, Y2, Z1, Z1 20 0
Condition B 1500 G, 0.5 msec. pulse.
ESD Method 3015 Human body model @ 8000 V 3 0
HFBR-1521
Human body model @ 2000V 3 0
HFBR-2521
Notes:
1. Devices were preconditioned with 10 second, 260°C solder dip and 20 cycles, -40°C to 85°C, temperature cycle.
2. Agilent procedure: 3 second flux cycle, 2 minute preheat at 95°C, 5 second wave solder at 255-265°C, 7 minute
cleaning at 60-70°C.