Strany 1 - Firmware Upgrade Kit

HP/Agilent 8922 GSM Test SetFirmware Upgrade KitAgilent Part No. 08922-90236Printed in UKJuly 1999

Strany 2

10HP/Agilent 8922S Firmware Upgrade Kit,08922-61149, Revision B.07.11Table 1-6 ROM Parts List for Agilent 08922-61149, HP/Agilent 8922SFirmware Upgrad

Strany 3 - 1 HP/Agilent 8922 Upgrade Kit

11HP/Agilent 8922S Option 010 FirmwareUpgrade Kit, 08922-61184, Revision C.01.08Table 1-7 ROM Parts List for Agilent 08922-61184, HP/Agilent 8922S Opt

Strany 4

12Clearing Non-Volatile MemoryNOTE It is important to Clear the HP/Agilent 8922 non-volatile RAM beforeand after the firmware upgrade.To clear non-vola

Strany 5 - 08922-61087, Revision A.05.04

13Removal InstructionsStep 1. Remove the instrument’s top cover.1. Remove the top bumper mounting screws (4 places).2. Remove the side bumper mounting

Strany 6 - 08922-61088, Revision A.04.02

14Figure 1-1 Location of A9 global test board and A33 Hop controllerNOTE If you are upgrading an HP/Agilent 8922F/H/S, go to step 5.Step 3. Replace A9

Strany 7 - 08922-61116, Revision B.06.07

15Figure 1-2 Location and orientation of A9 U264. Check the orientation of the EPROM A9U26 matches the templateshown on the board.5. Re-install the A9

Strany 8 - 08922-61089, Revision A.04.02

16Figure 1-4 Loosening the A8 memory board mounting screwsNOTE If your Memory Board is secured with two screws, remove the bottomcover for access (exp

Strany 9 - 08922-61117, Revision B.06.07

17Figure 1-5 Removing the bottom cover2. Remove the A8 Memory board only.3. Replace ROMs supplied in the kit in accordance with the diagrambelow.Figur

Strany 10 - 08922-61149, Revision B.07.11

18Figure 1-7 HP/Agilent 8922H/S Memory board IC replacement diagram4. Re-install the A8 Memory Board.NOTE Use the templates marked on the boards to co

Strany 11

19Figure 1-8 ROM U15 to U18 replacement3. Re-install the A32 GSM Controller board.

Strany 12 - Clearing Non-Volatile Memory

© Copyright 1999, Agilent Technologies. All rights reserved. Reproduction, adaptation, or translation without priorwritten permission is prohibited, e

Strany 13 - Removal Instructions

20Completing the ROM upgradeUpon initial powerupWhen new ROMs are installed in the HP/Agilent 8922, and theinstrument is first powered on, there may be

Strany 14

21Calibrating the Internal ReferenceTo complete the ROM upgrade, you must recalibrate the internalreference.NOTE Before recalibrating the internal ref

Strany 16

Printed in UKManufacturing Part Number08922-90236

Strany 17

31 HP/Agilent 8922 Upgrade KitInstructionsThe HP/Agilent 8922 Upgrade Kit instructions apply to the followingupgrade kits:• HP/Agilent 8922A/B GSM Tes

Strany 18

4Purpose of firmware upgrade kitsThe Agilent 8922 firmware upgrade kits allow you to upgrade the HP/Agilent 8922A/B/E/F/G/H/S Operating System firmware t

Strany 19

5HP/Agilent 8922A/B Firmware Upgrade Kit,08922-61087, Revision A.05.04Table 1-1 ROM Parts List for Agilent 08922-61087, HP/Agilent 8922A/BFirmware Upg

Strany 20 - Completing the ROM upgrade

6HP/Agilent 8922E Firmware Upgrade Kit,08922-61088, Revision A.04.02Table 1-2 ROM Parts List for Agilent 08922-61088, HP/Agilent 8922EFirmware Upgrade

Strany 21 - Verifying correct upgrade

7HP/Agilent 8922F Firmware Upgrade Kit,08922-61116, Revision B.06.07Table 1-3 ROM Parts List for Agilent 08922-61116, HP/Agilent 8922FFirmware Upgrade

Strany 22

8HP/Agilent 8922G Firmware Upgrade Kit,08922-61089, Revision A.04.02Table 1-4 ROM Parts List for Agilent 08922-61089, HP/Agilent 8922GFirmware Upgrade

Strany 23 - 08922-90236

9HP/Agilent 8922H Firmware Upgrade Kit,08922-61117, Revision B.06.07Table 1-5 ROM Parts List for Agilent 08922-61117, HP/Agilent 8922HFirmware Upgrade

Komentáře k této Příručce

Žádné komentáře