AgilentIntroduction to ApplicationDevelopment with the Agilent PNASeries of Network AnalyzersProduct Note

Strany 2 - Table of Contents

5.0 Introduction to ApplicationExamplesThe analyzer’s support for DCOM (DistributedComponent Object Model) over the LAN provides con-trol of the netwo

Strany 3 - 2.0 Basic Administration

5.1.1.2 Application CodeThe application code is contained below. To run theapplication, first generate the executable file. Once thisis complete, it c

Strany 4 - From your PC:

5.1.2 Microsoft Visual Basic ScriptExample5.1.2.1 Application ConfigurationSome operating systems may require that the VisualBasic Scripting engine be

Strany 5 - 3.0 Software Installation

5.1.3 Microsoft Word Example5.1.3.1 Application ConfigurationMicrosoft®Office 2000 was used for this example. Thisversion of Office contains Visual Ba

Strany 6 - 3.3 Software installation

5.1.3.3 Application OutputThe figure below shows the displayed results when theapplication is executed.5.1.4 Microsoft Excel Example5.1.4.1 Applicatio

Strany 7 - 4.0 Configuring COM/DCOM

For i = 0 To num_points - 1Sheet1.Cells(3 + i, 1) = result(i)NextSet chan = Nothingapp.QuitEnd Sub5.1.4.3 Application OutputThe figure below shows the

Strany 8

// Send a manual trigger to initiate a single sweeppChan->Single(true);// QueryInterface for the IArrayTransfer interface of the NetworkAnalyzer ob

Strany 9

5.1.6.2 Application CodeAgilent VEE version 6.0 or higher must be installed torun the application in this example. There is a runtimeversion of Agilen

Strany 10 - Examples

Appendix A: Quick Guide A) A system administrator grants logon access tothe PNA Series network analyzer for specific user.This step is also required f

Strany 11 - 5.1.1.3 Application Output

C) Configure the PNA Series network analyzer toprovide COM/DCOM access to the PNA applica-tion for a registered user on the network analyzer. If you

Strany 12 - 5.1.2.3 Application Output

Table of Contents1.0 Introduction...

Strany 13 - 5.1.3 Microsoft Word Example

Agilent Technologies‘ Test and Measurement Support, Services, and AssistanceAgilent Technologies aims to maximize thevalue you receive, while minimizi

Strany 14 - 5.1.4 Microsoft Excel Example

1.0 IntroductionThis product note provides a step-by-step guide to sys-tem administration, software installation, andCOM/DCOM setup on a PNA Series ne

Strany 15 - 5.1.5.2 Application Code

4) In the User name input box, enter the user name which the user logs in to his/her PC with. The Full name and Description boxes are optional and so

Strany 16 - 5.1.6 Agilent VEE Example

From the PNA network analyzer:1) Double click on the My Computer desktop icon todetermine if the C drive is “shared”.2) Single right click the C drive

Strany 17 - 5.1.7 National Instruments

From your PNA Series Network Analyzer:4) Next, map your PC’s CD drive to the network analyzer. Launch Windows®Explorer to begin this procedure.5) On t

Strany 18 - Appendix A:

4.0 Configuring COM/DCOMWhen configuring COM/DCOM, the first issue to considerin this topic is Windows®NT/Windows®2000 Domainsversus Workgroups.• A d

Strany 19 - Problems?

5) The Registry Value Permissions dialog box for Registry Value: Access Permission should now be visible. Click the Add... Button.6) The Add Users and

Strany 20

4.1.2 Configure the user’s PC for DCOM access tothe PNA applicationFrom your PC:1. Using your PC's Windows Explorer, find the analyzer’smapped lo