Agilent 54645D MSO Tutorial
© Agilent Technologies 1996-1997
All rights Reserved
Excerpts from Agilent 54645D Mixed-Signal Oscilloscope
Chapter 2: Front-Panel Overview
• To use digital channels to view a signal
• To display signals automatically using Autoscale
• To apply the default factory configuration
• To adjust oscilloscope vertical scaling
• To turn analog channels on and off
• To rearrange the analog channels
• To turn digital channels on and off (Agilent 54645D)
• To rearrange digital channels (Agilent 54645D)
• To operate the time base controls
• To start and stop an acquisition
• To make cursor measurements
Chapter 3: Triggering Agilent 54645A/D Oscilloscopes
• Trigger types
• To define a pattern trigger
• To use glitch triggering
• To define an advanced pattern trigger
Zobrazit stránku 0
1 2 3 4 5 6 ... 28 29

Shrnutí obsahu

Strany 1 - Agilent 54645D MSO Tutorial

Agilent 54645D MSO Tutorial© Agilent Technologies 1996-1997All rights ReservedExcerpts from Agilent 54645D Mixed-Signal OscilloscopeChapter 2: Front-P

Strany 2

To rearrange the digital channels (HP 54645D) 1Turn the Select knob to choose the digital channel you want to move.Only channels that are currently on

Strany 3 - , then press

To operate the time base controlsThe following exercise guides you through the time base keys, knobs, andstatus line.•Turn the Time/Div knob and notic

Strany 4

All events displayed left of the trigger point ▼ happened before the triggeroccurred, and these events are called pre-trigger information. You will f

Strany 5

To use the Entry and Select knobsThe Select knob (HP 54645D only) always changes the selected channel. Inmost menus, its order is screen-oriented. In

Strany 6

To make cursor measurementsThe following steps guide you through the front-panel Cursors key. You canuse the cursors to make custom voltage or time m

Strany 7 - Print/Utility

On HP 54645D, the Readout softkey gives a reading of the time orvoltage cursor measurement.•For the time cursor readout, you can select Time, Hex, Bin

Strany 8

To use delayed sweepDelayed sweep is a magnified portion of the main sweep. You can usedelayed sweep to locate and horizontally expand part of the ma

Strany 9

To modify the graticule1Press Display .2Press one of the Grid softkeys to define the graticule used for thewaveform area on the display.•Frame has a s

Strany 10 - D0-D15

To print the displayYou can print the waveform display and status line to an HP printer orEpson-compatible printer attached to one of these optional i

Strany 11

Trigger typesThese trigger types are available:•Edge trigger•Pattern trigger•Advanced triggerChanges to the trigger specification are applied when you

Strany 12 - Single

To use digital channels to view a signal•To configure the instrument quickly, press Autoscale .•To undo the effects of autoscale, press Setup , then p

Strany 13

Glitch TriggerThe advanced glitch trigger menu lets you select the analog (A1 or A2) ordigital (D0-D15) channel on which to capture a glitch event. Yo

Strany 14 - To make cursor measurements

Specifying a Logic ThresholdYou can specify a threshold for the logic channels. See “To change the logicthreshold for input signals” in chapter 4 for

Strany 15

Sharing of SourcesThe source definitions for the simple pattern trigger are shared with thePattern 1 and Edge 1 sources of the advanced pattern trigge

Strany 16 - To use delayed sweep

To define an edge trigger1Press Edge .2Select a channel as the trigger source using either the Select knob orby pressing a Trigger Source softkey.You

Strany 17 - To modify the graticule

To define a pattern trigger1Press Pattern .2For each analog channel (A1 or A2) or digital channel (D0-D15) youwant to include in the desired pattern,

Strany 18 - To print the display

To use glitch triggering1Press Advancd . Then select Glitch.2Select Glitch Menu.3Select the analog channel (A1 or A2) or digital channel (D0-D15)sour

Strany 19 - Trigger types

To define an advanced pattern triggerThe advanced triggering operation depends on previous selections in theAdvanced Trigger menu.1Press Advancd . The

Strany 20

5Select the source(s) for the trigger operator by pressing the leftmostSource softkey until the desired source is highlighted.Refer to the table of tr

Strany 21

9To set up a pattern trigger source, do the following: aSelect a channel for the source.•To set the condition for that channel, press the L, H, or X s

Strany 22

Setup rulesRemembering the following rules will make it easier to work with theadvanced triggering capabilities:•Duration operators are valid when onl

Strany 23 - To use line triggering

To display signals automatically using Autoscale •To configure the instrument quickly, press Autoscale .Autoscale displays all connected signals that

Strany 24 - To define a pattern trigger

During Autoscale, the delay is set to 0.0 seconds, the Time/Div setting is afunction of the input signal (about 2 periods of the triggered signal on t

Strany 25 - To use glitch triggering

To adjust oscilloscope vertical scalingThis exercise guides you through the vertical keys, knobs, and status line.1Center the signal on the display us

Strany 26

•Toggle each softkey and notice which keys cause the status line to change.Channels 1 and 2 have a vernier softkey that allows the Volts/Divknob to ch

Strany 27

To Expand the Vertical SignalWhen changing the Volts/Div for analog channels, you can have the signalexpand (or compress) about the signal offset or t

Strany 28

To turn analog channels on and off •To turn off analog channel #1, press 1 (on the HP 54645A),or A1 (on the HP 54645D), then press the leftmost sof

Strany 29

To turn digital channels on and off (HP 54645D)•To turn digital channels 0 through 7 on, press D0-D15 , thenpress the D0 - D7 On softkey. To turn th