Static reference sensitivity level
Purpose of measurementswhat it proves
Sensitivity is the most significant in-channel receiver test. The sensitivity test
proves that the receiver can receive, demodulate, and decode a very low-level
signal. Every base station manufacturer does this test. This test also proves
adjacent time slot rejection. The two adjacent time slots are required to have a
50 dB level above the time slot under test.
Theory in pictures
Graphical view of limits and specifications
Channel Type Error Parameter Limit Value %
RACH FER 0.5
TCH/F9.6 BER 0.001
TCH/FS FER 0.1α
Class Ib RBER 0.4/α
Class II RBER 2
Input signal in frequency domain
TS0 TS1 TS2
50 dB