Agilent Technologies E6392B Uživatelská příručka Strana 1

Procházejte online nebo si stáhněte Uživatelská příručka pro Sítě Agilent Technologies E6392B. Agilent Technologies E6392B User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 206
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Errata
Title & Document Type: E6392B GSM MS Test Set User’s Guide
Manual Part Number: E6392-90051
Revision Date: November 2001
HP References in this Manual
This manual may contain references to HP or Hewlett-Packard. Please note that
Hewlett-Packard's former test and measurement, semiconductor products and chemical
analysis businesses are now part of Agilent Technologies. We have made no changes to
this manual copy. The HP XXXX referred to in this document is now the Agilent XXXX.
For example, model number HP8648A is now model number Agilent 8648A.
About this Manual
We’ve added this manual to the Agilent website in an effort to help you support your
product. This manual provides the best information we could find. It may be incomplete
or contain dated information, and the scan quality may not be ideal. If we find a better
copy in the future, we will add it to the Agilent website.
Support for Your Product
Agilent no longer sells or supports this product. You will find any other available product
information on the Agilent Test & Measurement website:
www.tm.agilent.com
Search for the model number of this product, and the resulting product page will guide
you to any available information. Our service centers may be able to perform calibration
if no repair parts are needed, but no other support from Agilent is available
Zobrazit stránku 0
1 2 3 4 5 6 ... 205 206

Shrnutí obsahu

Strany 1

Errata Title & Document Type: E6392B GSM MS Test Set User’s Guide Manual Part Number: E6392-90051 Revision Date: November 2001 HP Refere

Strany 2 - User’s Guide

Contents 9Table of Contents1. Preparing for UseMajor Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 3 - E6392-90051

Chapter 3 99Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen Referenceo Trigger Sing/Cont: Toggles the trigger mode between Sing for single and

Strany 4 - Information

100 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)Screen FieldsThe following test parameters need to be specified for a new test:Input Field

Strany 5

Chapter 3 101Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceThe following display fields show the measurement results:Display Field

Strany 6

102 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)MANUAL TEST (Asynchronous Mode)NOTE The Asynchronous mode is only available for Test Sets

Strany 7 - GERXUSCHEMISSION

Chapter 3 103Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceStand-by ScreenIf the Mode Sync/Async/GPRS softkey is selected, the fol

Strany 8

104 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)Screen FieldsThe following parameters need to be specified for a new test:Input Field Des

Strany 9

Chapter 3 105Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceThe following test items are shown in groups in the table. The detailed

Strany 10 - Contents

106 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)ExplanationThe RF ON annunciator at the screen lower right corner is displayed only when

Strany 11

Chapter 3 107Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceMeasuring ScreenBy pressing the Start softkey, the following measuring

Strany 12

108 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)Measuring Screen ExamplesMeasuring: Peak TX Power/Burst Timing/Power RampThe actual measu

Strany 13

10 ContentsTest SIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Stand-by Screen

Strany 14 - 1 Preparing for Use

Chapter 3 109Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceIf the Abort softkey is pressed, another softkey menu is shown to activ

Strany 15 - Major Functions

110 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)o Knob MKR/Cursor: Toggles the function of the CURSOR CONTROL knob between Cursor and MKR

Strany 16

Chapter 3 111Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceMeasuring: Phase Error/Frequency ErrorThe RMS and Peak Phase Errors and

Strany 17 - Preparing for Use

112 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)NOTE If the measurement is not triggered, consult the following items.* The Power Control

Strany 18 - Installing the Test Set

Chapter 3 113Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceMeasuring: DC CurrentThe test data for the DC Current is displayed as s

Strany 19 - Power Cable

114 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)Measuring: Spectrum MonitorThe RF spectrum from 0 Hz to +400 kHz relative to the traffic

Strany 20 - 1. Preparing for Use

Chapter 3 115Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceIf the Abort softkey is pressed, another softkey menu is shown to activ

Strany 21 - Environment

116 Chapter 3 Screen ReferenceMANUAL TEST (Asynchronous Mode)Screen FieldsThe following test parameters need to be specified for a new test:Input Fiel

Strany 22 - Warm-Up Time

Chapter 3 117Screen ReferenceMANUAL TEST (Asynchronous Mode)3. Screen ReferenceThe following display fields show the measurement results:Display Field

Strany 23 - Preparation for Each Test

118 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)MANUAL TEST (GPRS Mode)NOTE The GPRS mode is only available for Test Sets with Option 040 .The ge

Strany 24 - UUT Connections

Contents 11Table of ContentsMemory Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Strany 25 - Entering Attenuations

Chapter 3 119Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceStand-by ScreenIf GPRS is selected in the Mode Sync/Async/GPRS softkey, the fol

Strany 26 - Troubleshooting

120 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)Screen FieldsThe following input fields of test parameters need to be set for a new test:Input Fi

Strany 27 - 26 Chapter 1

Chapter 3 121Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceDC PowerSelects a supply mode. The choices are On and Off as follows:o On: Alwa

Strany 28 - 2 Using Functions

122 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)The following test items are shown in groups in the table. The detailed test screens for the grou

Strany 29 - Using Functions

Chapter 3 123Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceIdle ScreenIn the attaching process after pressing the Start softkey, the follo

Strany 30 - 2. Using Functions

124 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)Attached ScreenUpon completion of the attaching process, the following measuring screen is shown.

Strany 31 - 30 Chapter 2

Chapter 3 125Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceProcedure to obtain the Measuring screensStep 1. Place the blinking cursor at o

Strany 32 - Chapter 2 31

126 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)Measuring Screen ExamplesMeasuring: Peak TX Power/Power vs TimeThe actual measurement data are sh

Strany 33 - 32 Chapter 2

Chapter 3 127Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceFigure 3-47 Aborted: Peak TX Power/Power vs Time ScreenFigure 3-48 Aborted: Pea

Strany 34 - Chapter 2 33

128 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)o Marker Coars/Fine: Toggles the marker control between Coars for coarse and Fine to move the mar

Strany 36 - Chapter 2 35

Chapter 3 129Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceMeasuring: Phase Error/Frequency ErrorThe RMS and Peak Phase Errors and Frequen

Strany 37 - 36 Chapter 2

130 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)Measuring: Sensitivity in BLERThe test data for BLER (block error rate) is displayed as shown in

Strany 38 - Chapter 2 37

Chapter 3 131Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceMeasuring: DC CurrentThe test data for the DC Current is displayed as shown in

Strany 39 - 38 Chapter 2

132 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)Measuring: Spectrum MonitorThe RF spectrum from 0 Hz to +400 kHz relative to the traffic channel

Strany 40 - Chapter 2 39

Chapter 3 133Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceIf the Abort softkey is pressed, another softkey menu is shown to activate the

Strany 41 - 40 Chapter 2

134 Chapter 3 Screen ReferenceMANUAL TEST (GPRS Mode)Screen FieldsThe following input fields of the parameters need to be specified for a new spectrum

Strany 42 - Chapter 2 41

Chapter 3 135Screen ReferenceMANUAL TEST (GPRS Mode)3. Screen ReferenceThe following display fields show the measurement results:Display Field Descrip

Strany 43 - 42 Chapter 2

136 Chapter 3 Screen ReferenceSPECTRUM MONITORSPECTRUM MONITORThis function mode is specialized for testing mobile phones, therefore the settings for

Strany 44 - Chapter 2 43

Chapter 3 137Screen ReferenceSPECTRUM MONITOR3. Screen Referenceo Knob MKR/Cursor: Toggles the function of the CURSOR CONTROL knob between Cursor and

Strany 45 - 44 Chapter 2

138 Chapter 3 Screen ReferenceSPECTRUM MONITORScreen FieldsThe following input fields of the test parameters need to be specified for a new test:Input

Strany 46 - Chapter 2 45

131. Preparing for Use1 Preparing for UseThis chapter is an overview of the Test Set’s major functions. It also describes the fundamental requirements

Strany 47 - 46 Chapter 2

Chapter 3 139Screen ReferenceSPECTRUM MONITOR3. Screen ReferenceThe following display fields show the measurement results:a. The variable increment so

Strany 48 - Chapter 2 47

140 Chapter 3 Screen ReferenceSPECTRUM MONITORMeasuring ScreensIf the Start softkey is pressed in the initial screen, the following Measuring screen w

Strany 49 - 48 Chapter 2

Chapter 3 141Screen ReferenceSPECTRUM MONITOR3. Screen ReferenceIf the Abort softkey is pressed in the measuring screen, the following aborted screen

Strany 50 - Chapter 2 49

142 Chapter 3 Screen ReferenceSPECTRUM MONITORo Marker Coars/Fine: Toggles the marker control between Coars for coarse and Fine to move the marker wit

Strany 51 - 50 Chapter 2

Chapter 3 143Screen ReferenceSIGNAL GENERATOR3. Screen ReferenceSIGNAL GENERATORThe Test Set is capable to generate RF signal dedicated to the radio s

Strany 52 - 3 Screen Reference

144 Chapter 3 Screen ReferenceSIGNAL GENERATORScreen FieldsThe following input fields of the test parameters need to be set to generate RF signal from

Strany 53 - General Operation Guide

Chapter 3 145Screen ReferenceCONFIGURATION3. Screen ReferenceCONFIGURATIONIn this mode there are three major functions of CONFIGURATION, File Manageme

Strany 54 - Chapter 3 53

146 Chapter 3 Screen ReferenceCONFIGURATIONScreen FieldsThe following input fields of the parameters need to be configured. The parameters are set usi

Strany 55 - Rear Panel Overview

Chapter 3 147Screen ReferenceCONFIGURATION3. Screen ReferenceNetwork ConfigSpecifies the network parameters. Setting these parameter is required when

Strany 56 - Display Annotation

148 Chapter 3 Screen ReferenceCONFIGURATIONTest Setup: Test Condition ScreenIf the Test Setup softkey in the CONFIGURATION screen is pressed, the Test

Strany 57 - Screen Flow Chart

14 Chapter 1 Preparing for UseMajor FunctionsMajor FunctionsFigure 1-1 Agilent E6392B GSM MS Test SetThe Agilent E6392B GSM MS Test Set has many desir

Strany 58 - Option 040

Chapter 3 149Screen ReferenceCONFIGURATION3. Screen ReferenceScreen FieldsThe following input fields of the parameters need to be defined with the pro

Strany 59 - 58 Chapter 3

150 Chapter 3 Screen ReferenceCONFIGURATIONBER BS LevelbSpecifies the RF output level of the Test Set for the Sensitivity test. The allowable range is

Strany 60 - Storing Two Numeric Values

Chapter 3 151Screen ReferenceCONFIGURATION3. Screen ReferenceSetting Test Limits on Test ItemsThe LO Limit and HI Limit values for the test items in t

Strany 61 - Variable Increment Softkey

152 Chapter 3 Screen ReferenceCONFIGURATIONRX QualityAccepts a set of high and low limits. The allowable choices are 0 (<0.2%), 1 (0.2 to 0.4%), 2

Strany 62 - Initial Screen

Chapter 3 153Screen ReferenceCONFIGURATION3. Screen ReferenceTest Setup: Test Sequence ScreenIf the Test Sequence softkey in the Test Setup: Test Cond

Strany 63 - 62 Chapter 3

154 Chapter 3 Screen ReferenceCONFIGURATIONAutomatic Test FlowFor creating a test flow to execute AUTOMATIC TEST, refer to Table 3-1.Select either MS

Strany 64 - AUTOMATIC TEST

Chapter 3 155Screen ReferenceCONFIGURATION3. Screen ReferenceScreen FieldsThe following input fields of the parameters need to be set for a new test s

Strany 65 - 64 Chapter 3

156 Chapter 3 Screen ReferenceCONFIGURATIONTCH (Talk)aSpecifies one traffic channel depending on the parameter selection in the Variable field.If TCH

Strany 66

Chapter 3 157Screen ReferenceCONFIGURATION3. Screen ReferenceThe following test items need to be set to either “Run” to execute a Pass/Fail test or to

Strany 67

158 Chapter 3 Screen ReferenceCONFIGURATIONCreating Instruction MessagesAn instruction message with up to 69 characters including spaces and symbols c

Strany 68

Chapter 1 15Preparing for UseMajor Functions1. Preparing for UseThere are three test modes for the MANUAL TEST mode: o Synchronous mode: Tests are mad

Strany 69

Chapter 3 159Screen ReferenceCONFIGURATION3. Screen Referenceo Over/Ins: Selects either Over (overwrite) or Ins (insert). Over enables you to overwrit

Strany 70 - Talk Measuring Screen

160 Chapter 3 Screen ReferenceCONFIGURATIONFile ManagementWhen the File Management softkey is pressed with a proper SRAM memory card inserted in the M

Strany 71

Chapter 3 161Screen ReferenceCONFIGURATION3. Screen Referenceo More (2 of 2): Returns to softkey menu 1.o Return: Displays the previous screen and the

Strany 72 - Aborted Screen

162 Chapter 3 Screen ReferenceCONFIGURATIONStep 5. Press the CURSOR CONTROL knob once to activate the Choices scrolling window with the blinking circu

Strany 73

Chapter 3 163Screen ReferenceCONFIGURATION3. Screen ReferenceSoftkey Menuo Save Execute: The operation message “OK to save?” is shown when this softke

Strany 74 - Pass/Fail Screen

164 Chapter 3 Screen ReferenceCONFIGURATIONStep 2. Move the cursor to the file number which you want to recall.Step 3. Press the Recall softkey, then

Strany 75

Chapter 3 165Screen ReferenceCONFIGURATION3. Screen ReferenceHow to Update the FirmwareIf Update is set to On and a firmware update card is inserted i

Strany 76 - Pass/Fail Screen Examples

166 Chapter 3 Screen ReferenceCONFIGURATIONIf a proper update card is not inserted when the OK softkey is pressed, the operation message “Insert the p

Strany 77 - 76 Chapter 3

1674. Functionality /Operation4 Functionality/OperationThis chapter introduces the typical block diagram of a GSM mobile phone to relate some blocks w

Strany 78 - Chapter 3 77

168 Chapter 4 Functionality/OperationGSM Mobile Block DiagramGSM Mobile Block DiagramFigure 4-1 shows the typical block diagram of a GSM mobile phone.

Strany 79 - 78 Chapter 3

16 Chapter 1 Preparing for UseMajor FunctionsNOTE The MANUAL TEST Asynchronous mode, the SPECTRUM MONITOR and the SIGNAL GENERATOR functions are avail

Strany 80 - Pass/Fail: DC Current

Chapter 4 169Functionality/OperationGSM Measurements Selection4. Functionality /OperationGSM Measurements SelectionIt is worthwhile to consider which

Strany 81 - Test SIM

170 Chapter 4 Functionality/OperationGSM Measurements SelectionRX BER Sensitivity Channel Synthesizer(BER 0% at −50 to −90 dBm)I/Q DemodulationEqualiz

Strany 82

Chapter 4 171Functionality/OperationGPRS Overview4. Functionality /OperationGPRS OverviewThis section summarizes the functional features of the Genera

Strany 83

172 Chapter 4 Functionality/OperationGPRS OverviewPSPDN: Packet Switched Public Data NetworkPSTN: Public Switched Telephone NetworkSGSN: Serving GP

Strany 84

1735. Specifications5 SpecificationsThis chapter provides the specifications of the Agilent E6392B GSM MS Test Set. These specifications are the stand

Strany 85

174 Chapter 5 SpecificationsGeneral InformationGeneral InformationSpecifications describe the test set’s warranted performance and are valid over the

Strany 86

Chapter 5 175SpecificationsRF Input/Output5. SpecificationsRF Input/OutputRF Signal GeneratorMaximum Safe Reverse Power (peak):+41 dBm (12.6 W; CW; su

Strany 87

176 Chapter 5 SpecificationsRF AnalyzerRF AnalyzerTransmitter Carrier Peak Power MeasurementPower Ramp MeasurementFrequency Range: 890 MHz to 915 MHz

Strany 88 - Chapter 3 87

Chapter 5 177SpecificationsRF Analyzer5. SpecificationsPhase and Frequency Error MeasurementSpectrum MonitorInput Level Range: −11 dBm to +39 dBmInput

Strany 89 - Talk/RF Test Measuring Screen

178 Chapter 5 SpecificationsDC Power SupplyDC Power SupplyDC Current MeasurementMemory CardRange: 3.0 Vdc to 11.0 VdcResolution: 0.1 VAccuracy: ±0.1 V

Strany 90 - Chapter 3 89

Chapter 1 17Preparing for UseInstalling the Test Set1. Preparing for UseInstalling the Test SetThis section contains the following procedures for prop

Strany 91

Chapter 5 179SpecificationsAsynchronous Test (Option 002)5. SpecificationsAsynchronous Test (Option 002)Spectrum MonitorRF Signal GeneratorFrequency R

Strany 92 - Chapter 3 91

180 Chapter 5 SpecificationsGPRS Test (Option 040)GPRS Test (Option 040)Specifications Unique for GPRS MeasurementSlot Configuration: Downlink 1 × Upl

Strany 93 - 92 Chapter 3

Chapter 5 181SpecificationsRear Panel5. SpecificationsRear PanelFrequency ReferenceSerial InterfacePrinter InterfaceFrequency: 13 MHzFrequency Accurac

Strany 94 - Chapter 3 93

182 Chapter 5 SpecificationsGeneral SpecificationsGeneral SpecificationsSize: 350 mm (W) × 150 mm (H) × 350 mm (D)Weight: 10 kg ± 10%Power Voltage: 90

Strany 95 - Softkey Menu 3

183A. General Informationon the GSM SystemA General Information on the GSM SystemFor your reference, some major information on the GSM system is descr

Strany 96 - Chapter 3 95

184 Appendix A General Information on the GSM SystemThe GSM SystemThe GSM SystemA GSM mobile phone transmits speech as bursts of encoded data. An RF c

Strany 97

Appendix A 185General Information on the GSM SystemThe GSM SystemA. General Informationon the GSM SystemPower Control LevelsThe power control levels,

Strany 98 - Chapter 3 97

186 Appendix A General Information on the GSM SystemThe GSM SystemRX LevelThe RX levels are defined as follows:# RX Level # RX Level # RX Level0 ≤110

Strany 99

Appendix A 187General Information on the GSM SystemThe GSM SystemA. General Informationon the GSM SystemRX QualityThe RX quality is defined as follows

Strany 100 - 3. Screen Reference

188 Appendix A General Information on the GSM SystemThe GSM System

Strany 101 - Screen Fields

18 Chapter 1 Preparing for UseInstalling the Test SetPower CableIn accordance with international safety standards, this instrument is equipped with a

Strany 102

189B. Input Fields and Allowable RangesB Input Fields and Allowable RangesHere is a table of the input fields and allowable ranges of values for test

Strany 103 - 102 Chapter 3

190 Appendix B Input Fields and Allowable RangesTable 0-1 Input Fields and Allowable Choices or RangesRadio StandardTest Mode Test Item, ParameterGSM9

Strany 104 - Stand-by Screen

Appendix B 191Input Fields and Allowable RangesB. Input Fields and Allowable RangesSensitivity:[GPRS mode]BLER(FER, BER, RX Quality, and RX Level can

Strany 105

192 Appendix B Input Fields and Allowable RangesAttenuation:RF In:RF Out:Off, On0.0 to 99.9 dB in 0.1 dB steps0.0 to 99.5 dB in 0.5 dB stepsNetwork Co

Strany 106

Appendix B 193Input Fields and Allowable RangesB. Input Fields and Allowable RangesConfiguration: SequenceTest Steps:1. LOC. Update:2. 1st Call:3. Tal

Strany 107 - Explanation

194 Appendix B Input Fields and Allowable Ranges

Strany 108 - Measuring Screen

195C. Manual ChangesC Manual Changes

Strany 109 - Measuring Screen Examples

196 Appendix C Manual ChangesIntroductionIntroductionThis appendix contains revision notes for adapting the information in this guide to correspond to

Strany 110 - Chapter 3 109

Index 197IndexNumerics13 MHz IN/OUT connectorrear panel 5413 MHz Referenceinput field 146AAbortsoftkey menu 69, 86, 88, 90, 96, 98, 107, 108, 114, 12

Strany 111 - 110 Chapter 3

Index198 instruction message 158cleaning instructionenvironmental requirement 21commandBk Space 159Cancel 158Del End 159Delete 159Done 158instruction

Strany 112 - Chapter 3 111

iAgilent TechnologiesE6392B GSM MS Test SetUser’s GuideSerial NumbersThis manual applies directly to instruments with serial number prefix JP5MG, or

Strany 113 - 112 Chapter 3

Chapter 1 19Preparing for UseInstalling the Test Set1. Preparing for UseFigure 1-2 Power Cable Supplied

Strany 114 - Measuring: DC Current

Index 199Indexcleaning instruction 21environment 20installing the test set 20FFailsoftkey menu 69FERtest limit 151File Managementsoftkey menu 145, 14

Strany 115 - Measuring: Spectrum Monitor

Index200 Panel Key 146PDTCH 120Printer 146Procedure 65, 82, 104, 120PWR CNTL 82, 100, 104, 116, 120, 134, 149Radio Standard 65, 82, 104, 120, 138, 14

Strany 116 - Chapter 3 115

Index 201IndexPower Ramp 90, 108Peak TX Power/Power vs Time 126Phase Error/Frequency Error 93, 111, 129screen field 100, 116, 134Sensitivity BER 130S

Strany 117

Index202 asynchronous mode 111GPRS mode 129measuring screen 93, 111, 129pass/fail screen 77Positioncommand 158power cableinstalling the test set 18Po

Strany 118

Index 203Index122SPECTRUM MONITOR 138stand-by screen 65, 82, 104, 120talk measuring screen 70test condition screen 149test flow step 65test item 66te

Strany 119 - MANUAL TEST (GPRS Mode)

Index204 96, 97, 98, 99, 108, 109, 111, 113, 114, 115, 126, 127, 129, 130, 131, 132, 133, 136, 140, 141Yes 163, 165Zoom Off/On 76, 91, 109, 127Spanin

Strany 120

Index 205Indexpreparation for each test 22testing examplesAUTOMATIC TEST 29MANUAL TESTasynchronous mode 40GPRS mode 44synchronous mode 34SPECTRUM MON

Strany 121

20 Chapter 1 Preparing for UseInstalling the Test SetMeeting Electrical and Environmental RequirementsLine SettingsThe available ac power source must

Strany 122

Chapter 1 21Preparing for UseInstalling the Test Set1. Preparing for UseProviding Adequate VentilationCooling holes are located on the bottom of the i

Strany 123

22 Chapter 1 Preparing for UsePreparation for Each TestPreparation for Each TestThe following procedures need to be executed before starting each test

Strany 124 - Idle Screen

Chapter 1 23Preparing for UsePreparation for Each Test1. Preparing for UseAdjusting the Display ContrastYou can adjust the display contrast by control

Strany 125 - Attached Screen

24 Chapter 1 Preparing for UsePreparation for Each TestEntering AttenuationsDetermine and enter the appropriate attenuation values caused by the anten

Strany 126 - CONTROL knob

Chapter 1 25Preparing for UseTroubleshooting1. Preparing for UseTroubleshootingNo Measurement after StartCheck if the 13 MHz Reference field of the CO

Strany 127

26 Chapter 1 Preparing for UseTroubleshooting

Strany 128 - Chapter 3 127

272. Using Functions2 Using FunctionsIn this chapter, a few testing examples are discussed. This may help the first time user get familiar with the ba

Strany 129 - 128 Chapter 3

28 Chapter 2 Using FunctionsTesting a Mobile Phone with the Test SetTesting a Mobile Phone with the Test SetIn this chapter, the following testing exa

Strany 130 - Chapter 3 129

ii Manual Part Number E6392-90051Edition/Print DateAll Editions and Updates of this manual and their creation dates are listed below.First Edition...

Strany 131 - 130 Chapter 3

Chapter 2 29Using FunctionsTesting a Dual Band Mobile with AUTOMATIC TEST2. Using FunctionsTesting a Dual Band Mobile with AUTOMATIC TESTThe next proc

Strany 132

30 Chapter 2 Using FunctionsTesting a Dual Band Mobile with AUTOMATIC TESTStep 6. Set the highlighted fields of the test parameters as shown in the ab

Strany 133

Chapter 2 31Using FunctionsTesting a Dual Band Mobile with AUTOMATIC TEST2. Using FunctionsStep 12. Press the Test Condition softkey to go to the next

Strany 134 - Chapter 3 133

32 Chapter 2 Using FunctionsTesting a Dual Band Mobile with AUTOMATIC TESTStep 19. At the MS Call step, you are asked to call from the mobile. For exa

Strany 135

Chapter 2 33Using FunctionsTesting a Dual Band Mobile with AUTOMATIC TEST2. Using Functions• Press the Print All softkey to print the detailed measure

Strany 136

34 Chapter 2 Using FunctionsTesting a Dual Band Mobile with MANUAL TEST (Synchronous mode)Testing a Dual Band Mobile with MANUAL TEST (Synchronous mod

Strany 137 - SPECTRUM MONITOR

Chapter 2 35Using FunctionsTesting a Dual Band Mobile with MANUAL TEST (Synchronous mode)2. Using FunctionsStep 6. Specify the higlighted fields of th

Strany 138

36 Chapter 2 Using FunctionsTesting a Dual Band Mobile with MANUAL TEST (Synchronous mode)• If the BS Call softkey is pressed, you are asked to answer

Strany 139

Chapter 2 37Using FunctionsTesting a Dual Band Mobile with MANUAL TEST (Synchronous mode)2. Using Functions• If the MS Call softkey is pressed, the fo

Strany 140

38 Chapter 2 Using FunctionsTesting a Dual Band Mobile with MANUAL TEST (Synchronous mode)a. Press the Trigger Sing/Cont softkey to change the trigger

Strany 141 - Measuring Screens

iiiSafety InformationThe following general safety precautions must be observed during all phases of operation, service, and repair of this instrumen

Strany 142 - Chapter 3 141

Chapter 2 39Using FunctionsTesting a Dual Band Mobile with MANUAL TEST (Synchronous mode)2. Using Functions• When you press the BS Release softkey, wa

Strany 143 - 142 Chapter 3

40 Chapter 2 Using FunctionsTesting a Mobile with MANUAL TEST (Asynchronous mode)Testing a Mobile with MANUAL TEST (Asynchronous mode)The following pr

Strany 144 - SIGNAL GENERATOR

Chapter 2 41Using FunctionsTesting a Mobile with MANUAL TEST (Asynchronous mode)2. Using FunctionsIf you want to supply dc power from the Test Set to

Strany 145

42 Chapter 2 Using FunctionsTesting a Mobile with MANUAL TEST (Asynchronous mode)Step 13. Press the Start softkey, and the next MANUAL TEST: Measuring

Strany 146 - CONFIGURATION

Chapter 2 43Using FunctionsTesting a Mobile with MANUAL TEST (Asynchronous mode)2. Using FunctionsStep 16. Press the Return softkey to reveal the next

Strany 147

44 Chapter 2 Using FunctionsTesting a Mobile with MANUAL TEST (GPRS mode)Testing a Mobile with MANUAL TEST (GPRS mode)The following procedure explains

Strany 148

Chapter 2 45Using FunctionsTesting a Mobile with MANUAL TEST (GPRS mode)2. Using FunctionsAt one field, press the CURSOR CONTROL knob, then rotate it.

Strany 149 - 148 Chapter 3

46 Chapter 2 Using FunctionsTesting a Mobile with MANUAL TEST (GPRS mode)Step 13. Press the Start softkey, then the screen changes to the following MA

Strany 150

Chapter 2 47Using FunctionsTesting a Mobile with MANUAL TEST (GPRS mode)2. Using Functionsa. Press the Trigger Sing/Cont softkey to change the trigger

Strany 151

48 Chapter 2 Using FunctionsTesting a Mobile with SPECTRUM MONITORTesting a Mobile with SPECTRUM MONITORThis procedure describes a test on an E-GSM mo

Strany 152

iv DO NOT Substitute Parts Or Modify InstrumentBecause of the danger of introducing additional hazards, do not install substitute parts or perform un

Strany 153

Chapter 2 49Using FunctionsTesting a Mobile with SPECTRUM MONITOR2. Using FunctionsIf you want to supply dc power from the Test Set to the mobile phon

Strany 154 - Chapter 3 153

50 Chapter 2 Using FunctionsTesting a Mobile with SPECTRUM MONITOR

Strany 155 - Automatic Test Flow

513. Screen Reference3 Screen ReferenceIn this chapter, each screen of the Test Set is explained in detail including the operational features and the

Strany 156

52 Chapter 3 Screen ReferenceGeneral Operation GuideGeneral Operation GuideThis section outlines how to operate the Test Set.Front Panel OverviewThe T

Strany 157

Chapter 3 53Screen ReferenceGeneral Operation Guide3. Screen Reference• Controlling the marker: For the graphic displays in the MANUAL TEST and SPECTR

Strany 158

54 Chapter 3 Screen ReferenceGeneral Operation GuideRear Panel OverviewThe following illustration shows the rear panel of the Test Set:Figure 3-2 Rear

Strany 159 - Creating Instruction Messages

Chapter 3 55Screen ReferenceGeneral Operation Guide3. Screen ReferenceDisplay AnnotationDepending on functions and test situations there are several t

Strany 160 - Chapter 3 159

56 Chapter 3 Screen ReferenceGeneral Operation GuideScreen Flow ChartThe following illustrations show the screen flow charts according to each functio

Strany 161 - File Management

Chapter 3 57Screen ReferenceGeneral Operation Guide3. Screen ReferenceFigure 3-5 Screen Flow ChartNOTE Refer to "MANUAL TEST (GPRS Mode)" on

Strany 162 - Saving a Test Setup File

58 Chapter 3 Screen ReferenceGeneral Operation GuideTest Parameters, Test Items and Allowable RangesDepending on the function modes, the Test Set has

Strany 164 - Recalling a Test Setup File

Chapter 3 59Screen ReferenceGeneral Operation Guide3. Screen ReferenceStoring Two Numeric ValuesFor numeric input fields such as channel numbers, inpu

Strany 165 - 164 Chapter 3

60 Chapter 3 Screen ReferenceGeneral Operation GuideRecalling the Numeric ValuesStep 1. Move the cursor to one of the numeric input fields of channels

Strany 166 - How to Update the Firmware

Chapter 3 61Screen ReferenceInitial Screen3. Screen ReferenceInitial ScreenAfter power on, the initial screen can be used to select one of the functio

Strany 167 - 166 Chapter 3

62 Chapter 3 Screen ReferenceInitial Screeno CONFIGURATION: Displays the CONFIGURATION screen and its softkey menu. Screens for setting up the test se

Strany 168 - 4 Functionality/Operation

Chapter 3 63Screen ReferenceAUTOMATIC TEST3. Screen ReferenceAUTOMATIC TESTIn this test mode, Pass/Fail test results on all test items in the table ar

Strany 169 - GSM Mobile Block Diagram

64 Chapter 3 Screen ReferenceAUTOMATIC TESTFigure 3-8 Stand-by Detailed ScreenSoftkey Menuo Start: Begins testing the mobile with AUTOMATIC TEST.o Scr

Strany 170 - GSM Measurements Selection

Chapter 3 65Screen ReferenceAUTOMATIC TEST3. Screen ReferenceScreen FieldsThe test flow steps from LOC. Update to BS/MS Release are shown to display w

Strany 171 - −102 dBm)

66 Chapter 3 Screen ReferenceAUTOMATIC TESTIf the Screen Simp/Detai softkey is selected, the test items in the table below are shown. Pass/Fail test r

Strany 172 - GPRS Overview

Chapter 3 67Screen ReferenceAUTOMATIC TEST3. Screen ReferenceIf some items are denoted to be skipped on the Test Setup: Test Sequence screen, or if th

Strany 173 - 172 Chapter 4

68 Chapter 3 Screen ReferenceAUTOMATIC TESTThe following display fields remain blank on the lower screen at this state:Display Field DescriptionIMSI:D

Strany 174 - 5 Specifications

vi ACOUSTIC NOISE EMISSIONLpA < 70 dBoperator positionnormal operationper ISO 7779GERXUSCHEMISSIONLpA < 70 dBam Arbeitsplatznormaler Betriebnac

Strany 175 - General Information

Chapter 3 69Screen ReferenceAUTOMATIC TEST3. Screen ReferenceTalk Measuring ScreenWhile the measurement is being done after pressing the Start softkey

Strany 176 - RF Signal Generator

70 Chapter 3 Screen ReferenceAUTOMATIC TESTScreen FieldsAfter the Start softkey is pressed in the Stand-by screen, the measurement is initiated and th

Strany 177 - RF Analyzer

Chapter 3 71Screen ReferenceAUTOMATIC TEST3. Screen ReferenceAborted ScreenIf the measurement is aborted by pressing the Abort softkey, either the AUT

Strany 178 - Spectrum Monitor

72 Chapter 3 Screen ReferenceAUTOMATIC TESTo Return: Displays the initial screen with function modes.ExplanationDetailed test results up to the aborte

Strany 179 - Memory Card

Chapter 3 73Screen ReferenceAUTOMATIC TEST3. Screen ReferencePass/Fail ScreenWhen a test is completed, either of the Pass/Fail simplified screen (Figu

Strany 180

74 Chapter 3 Screen ReferenceAUTOMATIC TESTo Return: Displays the initial screen with function modes.ExplanationIn the Pass/Fail detailed screen, the

Strany 181 - GPRS Test (Option 040)

Chapter 3 75Screen ReferenceAUTOMATIC TEST3. Screen ReferencePass/Fail Screen ExamplesThe following illustrations show some of the typical detailed sc

Strany 182 - Rear Panel

76 Chapter 3 Screen ReferenceAUTOMATIC TESTPass/Fail: Burst Timing/Power RampThis function measures and analyzes the power burst timing and the amplit

Strany 183 - General Specifications

Chapter 3 77Screen ReferenceAUTOMATIC TEST3. Screen ReferencePass/Fail: Phase Error/Frequency ErrorThis function measures and analyzes the rms and pea

Strany 184 - A. General Information

78 Chapter 3 Screen ReferenceAUTOMATIC TESTPass/Fail: Sensitivity/RX Quality/RX LevelThis function measures and analyzes the receiver sensitivity in t

Strany 185 - The GSM System

viiIn this Book This guide describes how to use the Agilent Technologies E6392B GSM MS Test Set. This Test Set provides a variety of test functions

Strany 186 - Power Control Levels

Chapter 3 79Screen ReferenceAUTOMATIC TEST3. Screen ReferencePass/Fail: DC CurrentThis function measures and analyzes the dc currents consumed at the

Strany 187 - RX Level

80 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)MANUAL TEST (Synchronous Mode)In the MANUAL TEST mode, each test item or a group of test it

Strany 188 - Limits for Frequency Error

Chapter 3 81Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceStand-by ScreenWhen the MANUAL TEST mode is selected, the following Stand

Strany 189 - 188 Appendix A

82 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)Screen FieldsThe input fields of the following parameters need to be set for a new test:Inp

Strany 190 - Allowable Ranges

Chapter 3 83Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceDC PowerSelects a supply mode. The choices are On and Off as follows:o On

Strany 191

84 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)The following test items are shown in groups in the table. The detailed test screens for th

Strany 192

Chapter 3 85Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceThe following display fields remain blank on the lower screen at this sta

Strany 193 - 192 Appendix B

86 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)MS Call or BS Call Measuring ScreenWhen the BS Call or MS Call softkey is pressed, the foll

Strany 194 - Appendix B 193

Chapter 3 87Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceScreen" on page 88. If the response from the mobile takes too much t

Strany 195 - 194 Appendix B

88 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)Talk/RF Test Measuring ScreenWhile the Talk/RF Test step is blinking as shown in Figure 3-2

Strany 197 - Introduction

Chapter 3 89Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceStep 2. Choose that test item by pressing the CURSOR CONTROL knob.Step 3.

Strany 198

90 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)Measuring Screen ExamplesMeasuring: Peak TX Power/Burst Timing/Power RampThe actual measure

Strany 199

Chapter 3 91Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceFigure 3-26 Aborted: Peak TX Power/Burst Timing/Power Ramp ScreenFigure 3

Strany 200

92 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)o Marker Coars/Fine: Toggles the marker control between Coars for coarse and Fine to move t

Strany 201

Chapter 3 93Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceMeasuring: Phase Error/Frequency ErrorThe RMS and Peak Phase Error and Fr

Strany 202

94 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)Softkey Menu 3o Print: Allows you to print a hardcopy of a graphic image from the screen.o

Strany 203

Chapter 3 95Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceMeasuring: Sensitivity/RX Quality/RX LevelThe test data for BER, FER, RX

Strany 204

96 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)Measuring: DC CurrentNOTE DC current measurements can be executed only when the DC Power fi

Strany 205

Chapter 3 97Screen ReferenceMANUAL TEST (Synchronous Mode)3. Screen ReferenceSoftkey Menu 1o Start: Begins a new test.o Trigger Sing/Cont: Toggles the

Strany 206

98 Chapter 3 Screen ReferenceMANUAL TEST (Synchronous Mode)Measuring: Spectrum MonitorThe RF spectrum of the traffic channel can be measured with Spec

Komentáře k této Příručce

Žádné komentáře