Agilent PXT Wireless Communications Test Set
User’s Guide
41
UDP Setting
(User Datagram Protocol)
The User Datagram Protocol (UDP) setting enables you to set the source and destination ports for this
network protocol.
To activate this function, you must select UDPv4 by pressing Func > DTCH Test > Parameter > Format
until this option is underlined.
Key Path: Mode > BSE > Func > DTCH Test > Parameter
Source Port
Sets the port number from which the datagram is sent.
Mode > BSE > Func > DTCH Test > Parameter > UDP Setting
Destination Port
Sets the port number to which the datagram is sent.
Key Path: Func > DTCH Test > Parameter > UDP Setting
Mode > BSE > Func > DTCH Test > Parameter > UDP Setting
Transfer Mode
Auto: When DTCH Test is turned On, (by pressing Func > DTCH Test > Test) a setting of Auto
continuously sends datagrams to the UE for the duration of the test. (In general, this is one transport block
per subframe (or two transport blocks per subframe for a TM3 (Transmission Mode 3) or TM4
(Transmission Mode 4) configuration).
Manual: Enables the Manual Transfer function located by pressing Func > DTCH Test.
Key Path
Mode > BSE > Func > DTCH Test > Parameter
Komentáře k této Příručce