Agilent Technologies Agilent E5810A Uživatelská příručka Strana 1

Procházejte online nebo si stáhněte Uživatelská příručka pro Brány / ovladače Agilent Technologies Agilent E5810A. Agilent Technologies Agilent E5810A User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 159
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User’s Guide

Agilent E5810ALAN/GPIB Gateway for Windows®User’s Guide

Strany 2

10 Accessing an Electronic Copy of This GuideThere are three ways you can access an electronic (.pdf) version of this guide, as follows. You will nee

Strany 3 - Front Matter

100 Chapter 3Using E5810A Web AccessOther Web Access FunctionsAgilent FTP site is Accessible From E58101 Verify the E5810 is Idle. Updating the E5810

Strany 4 - Declaration of Conformity

Chapter 3 101Using E5810A Web AccessOther Web Access Functions4 Perform Firmware Updatea Click the Update Firmware button to display a password dialog

Strany 5 - Safety Symbols

102 Chapter 3Using E5810A Web AccessOther Web Access Functions2 Install FTP Server, if Needed. You will need to access a standard FTP Server program.

Strany 6 - WARNINGS

Chapter 3 103Using E5810A Web AccessOther Web Access Functions7 Configure FTP Parameters and Filename. Enter the following information in the dialog b

Strany 7 - Support Information

104 Chapter 3Using E5810A Web AccessOther Web Access Functionsc The LAN LEDs should light, indicating LAN activity is taking place. The firmware for t

Strany 8 - User’s Guide Information

Chapter 3 105Using E5810A Web AccessOther Web Access Functions2 If the Update was Unsuccessful. If the last message in the system log indicates the E5

Strany 9 - What’s in This

106 Chapter 3Using E5810A Web AccessOther Web Access FunctionsNotes:

Strany 10 - Documentation

4Troubleshooting Information

Strany 11 - Table of Contents

108 Chapter 4Troubleshooting InformationThis chapter gives guidelines to troubleshoot problems that may occur with the E5810A LAN/GPIB Gateway for Win

Strany 12

Chapter 4 109Troubleshooting InformationTroubleshooting OverviewTroubleshooting OverviewThis figure shows a typical network configuration using the E5

Strany 13 - E5810A Description

Table of Contents 11Table of Contents1 E5810A DescriptionE5810 Hardware Description ... 15Typic

Strany 14

110 Chapter 4Troubleshooting InformationChecking the E5810AChecking the E5810AThis section gives guidelines to check the E5810A, including: Checking

Strany 15 - E5810 Hardware Description

Chapter 4 111Troubleshooting InformationChecking the E5810AChecking Front Panel Display Error MessagesThis table shows E5810 front panel display error

Strany 16 - Connections

112 Chapter 4Troubleshooting InformationChecking the E5810AERROR: IP in use<addr>The E5810 tried to use an IP address that is currently being us

Strany 17 - Display/LEDs

Chapter 4 113Troubleshooting InformationChecking the E5810AChecking E5810A ParametersIf the front panel display and LEDs indicate no error conditions,

Strany 18 - Sequence

114 Chapter 4Troubleshooting InformationChecking the NetworkChecking the NetworkIf the E5810 is correctly installed and configured and is operational,

Strany 19 - Preset Button

Chapter 4 115Troubleshooting InformationChecking the NetworkChecking Web Browser SettingsThe E5810 Web access (web server) generates web pages that de

Strany 20 - 20 Chapter 1

116 Chapter 4Troubleshooting InformationChecking the NetworkDoing this usually causes the browser to first look in its cache to see if the page exists

Strany 21

Chapter 4 117Troubleshooting InformationChecking the NetworkSteps to Set Proxy Notification (Microsoft Internet Explorer 5.0, 5.5)1 From Internet Expl

Strany 22 - E5810A Software/Firmware

118 Chapter 4Troubleshooting InformationChecking the NetworkSICL Timeout Set to 0 (infinite)The E5810 uses the LAN maximum timeout configured in Conne

Strany 23 - E5810A Operating Features

Chapter 4 119Troubleshooting InformationChecking PC Client ConnectionsChecking PC Client ConnectionsEven if the E5810 has been successfully configured

Strany 24

12 Table of Contents E5810A Support Information ...79E5810A Documentation ...

Strany 25 - Architecture

120 Chapter 4Troubleshooting InformationChecking PC Client ConnectionsExample: Using the ping CommandTo send a ping command from your PC to an E5810,

Strany 26 - With the E5810

Chapter 4 121Troubleshooting InformationChecking PC Client ConnectionsChecking syslog MessagesThe syslog messages can be viewed by typing <E5810 IP

Strany 27 - Chapter 1 27

122 Chapter 4Troubleshooting InformationChecking PC Client Connectionssyslog Messages The following table lists common syslog messages generated by th

Strany 28 - Assignment

Chapter 4 123Troubleshooting InformationChecking PC Client ConnectionsExample: Typical syslog MessagesThis table shows typical syslog messages and pro

Strany 29 - Agilent IO Libraries Suite

124 Chapter 4Troubleshooting InformationChecking PC Client ConnectionsRuntime Error MessagesCommon runtime errors that may occur in your programs when

Strany 30 - Using E5810 Web

Chapter 4 125Troubleshooting InformationChecking PC Client Connectionsviopen fails or I/O operation fails: Out of resourcesThe E5810 was unable to ope

Strany 31 - Language

126 Chapter 4Troubleshooting InformationChecking PC Client ConnectionsE5810 appears to be hungThere are several possible causes. For all of the follow

Strany 32

Chapter 4 127Troubleshooting InformationChecking InstrumentsChecking InstrumentsThis section gives guidelines to check connected GPIB and RS-232 instr

Strany 33 - Installing the E5810A

128 Chapter 4Troubleshooting InformationChecking InstrumentsChecking RS-232 InstrumentsIf you cannot establish communication with a connected RS-232 i

Strany 34

AE5810A Specifications

Strany 36

130 Appendix AE5810A SpecificationsThis appendix lists E5810 LAN/GPIB Gateway for Windows technical specifications, supplementary information, and sup

Strany 37 - Before You Install the E5810A

Appendix A 131E5810A SpecificationsSpecifications and Supplementary InformationSpecifications and Supplementary InformationGeneral RequirementsMinimum

Strany 38

132 Appendix A E5810A SpecificationsSpecifications and Supplementary InformationEnvironmental SpecificationsOperating Environment0oC to 55oC - Indoor

Strany 39 - Getting Network Information

Appendix A 133E5810A SpecificationsSpecifications and Supplementary InformationSupplementary InformationGPIB Modes of Operation SupportedThe E5810 sup

Strany 40

134 Appendix A E5810A SpecificationsSupported Network ProtocolsSupported Network ProtocolsThe E5810 uses the network IP and Ethernet protocols listed

Strany 42

136 Appendix BUsing the Telnet UtilityThis appendix explains how to access and exit the Telnet utility. It also summarizes various Telnet commands you

Strany 43 - E5810 Hub/Switch

Appendix B 137Using the Telnet UtilityUsing the Telnet UtilityUsing the Telnet UtilityFor backward compatibility with the E2050 LAN/GPIB Gateway, the

Strany 44

138 Appendix BUsing the Telnet UtilityUsing the Telnet UtilityExiting the Telnet UtilityTo exit the Telnet utility, use these Telnet commands.  If yo

Strany 45 - Apply Power to the

Appendix B 139Using the Telnet UtilityUsing the Telnet UtilityTypical Telnet Screen DisplayA typical display screen for an E5810 follows. The configur

Strany 46 - Communication

14 Chapter 1E5810A DescriptionThis chapter gives guidelines to install, configure, and troubleshoot the E5810A LAN/GPIB Gateway for Windows (E5810) fo

Strany 47 - Network Operation

140 Appendix BUsing the Telnet UtilityTelnet Commands for the E5810ATelnet Commands for the E5810AThis table lists the Telnet commands you can use wit

Strany 48 - dialog box

Appendix B 141Using the Telnet UtilityTelnet Commands for the E5810ACommand Descriptiongpib-name <string*15> View/Set the GPIB SICL Interface

Strany 49 - Chapter 2 49

142 Appendix BUsing the Telnet UtilityTelnet Commands for the E5810ANotes:

Strany 51 - Chapter 2 51

144 GlossaryGlossaryA addressA string uniquely identifying a particular interface or a device on that interface which is interpreted at the E5810 LAN/

Strany 52

Glossary 145DHCPShort for Dynamic Host Configuration Protocol, a protocol for assigning dynamic IP addresses to devices on a network. With dynamic add

Strany 53 - Enter key

146 GlossaryG gatewayHardware that permits a network connection between the LAN that your computer understands and the instrument specific interface

Strany 54 - 54 Chapter 2

Glossary 147I instrumentA device that accepts commands and performs a test or measurement function.interfaceA connection and communication media betwe

Strany 55 - Click this icon

148 GlossaryL LANLocal Area Network. A computer network that spans a relatively small area. Most LANs are confined to a single building or group of b

Strany 56

Glossary 149N network protocolsThe E5810 supports these network protocols: ARP, DHCP, DNS, FTP, HTTP, ICMP, and RPC. ARP: Short for Address Resolution

Strany 57 - Chapter 2 57

Chapter 1 15E5810A DescriptionE5810 Hardware DescriptionE5810 Hardware DescriptionThe E5810 LAN/GPIB Gateway for Windows provides a gateway between ne

Strany 58

150 GlossaryInstead of forwarding the request to the Web server where Page 1 resides, which can be a time-consuming operation, the proxy server retur

Strany 59 - for details

Glossary 151SRQService Request. An asynchronous request (an interrupt) from a remote device indicating that the device requires servicing.subnetA port

Strany 60 - 60 Chapter 2

152 GlossaryswitchA device that filters and forwards packets between LAN segments. Switches operate at the data link layer (layer 2) and sometimes th

Strany 61 - IO Libraries Suite

Glossary 153 Option OFF: The E5810 is not UPnP capable and will not announce its presence as a UPnP device when mounted to the network. V VEEThe Agil

Strany 62

154 GlossaryNotes:

Strany 63

Index 155IndexAaddress, 144Agilent IO Libraries Suitecheck for installed version, 61Agilent Web sites, 8Agilent, contacting, 8ASRL, 144Bbridge, 144Cca

Strany 64 - 64 Chapter 2

156 Index Using the Instruments Page, 96Using the ping Command, 120Using VISA Assistant, 68VISA LAN Client Addressing, 70FFind button, 93finding instr

Strany 65

Index 157RS232 Flow Control, 89RS232 Parity, 90RS232 SICL Interface Name, 90RS232 SRQ, 90RS232 Stop Bits, 90runtime error messages, 124Ssafety, 5seria

Strany 66

158 Index THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Strany 67 - Chapter 2 67

© Agilent Technologies, Inc. 2002–2013Printed in MalaysiaTwelfth Edition, October 8, 2013E5810-90001www.agilent.comAgilent TechnologiesContact usTo ob

Strany 68 - Interactive IO

16 Chapter 1E5810A DescriptionE5810 Hardware DescriptionLocal Network ConnectionsTypically, a hub or switch is used for local network configuration. A

Strany 69 - Documents

Chapter 1 17E5810A DescriptionE5810 Hardware DescriptionFront Panel FeaturesThis section describes the E5810 front panel features,Front Panel Display/

Strany 70

18 Chapter 1E5810A DescriptionE5810 Hardware DescriptionTypical Power-On SequenceThis figure shows major steps in a typical power-on sequence for an E

Strany 71 - Instruments with

Chapter 1 19E5810A DescriptionE5810 Hardware DescriptionPower-On (Default) SettingsWhen power is first applied to the E5810 and the hardware self-test

Strany 72

THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Strany 73

20 Chapter 1E5810A DescriptionE5810 Hardware Description Depress and Hold the Preset Button (>10 Seconds)** Hostname IP Address Temporary Pass

Strany 74

Chapter 1 21E5810A DescriptionE5810 Hardware DescriptionRear Panel FeaturesThis figure shows the rear panel features of the E5810.Rack Mount Kit (Opti

Strany 75 - Welcome page is the home

22 Chapter 1E5810A DescriptionE5810A Software/FirmwareE5810A Software/FirmwareThe E5810 LAN/GPIB Gateway for Windows provides an interface (gateway) t

Strany 76 - Using the Welcome Page

Chapter 1 23E5810A DescriptionE5810A Software/FirmwareE5810A Operating FeaturesFeature DescriptionRemote access to instruments via LANAccess and contr

Strany 77 - Navigation Bar

24 Chapter 1E5810A DescriptionE5810A Software/FirmwareTypical Network OperationThe E5810 provides a network gateway between network-equipped computer

Strany 78 - E5810A Current Settings

Chapter 1 25E5810A DescriptionE5810A Software/FirmwareSoftware/Firmware ArchitectureTo program instruments from your PC via the E5810 using a programm

Strany 79 - E5810A Support Information

26 Chapter 1E5810A DescriptionE5810A Software/FirmwareHow IO Application Software Works With the E5810Before trying to perform an I/O application oper

Strany 80 - E5810A Documentation

Chapter 1 27E5810A DescriptionE5810A Software/FirmwareTypical Network IP AddressingThis section describes typical Enterprise network IP addresses and

Strany 81 - Chapter 3 81

28 Chapter 1E5810A DescriptionE5810A Software/FirmwareSubnet Addressing A Subnet Mask is used to determine to which subnet an IP address belongs. An I

Strany 82 - Configuration Page

Chapter 1 29E5810A DescriptionE5810A Software/FirmwareCommunicating with the E5810AThere are two ways you can communicate with the E5810 via a network

Strany 83

3Front MatterNoticeThe information contained in this document is subject to change without notice.Agilent Technologies shall not be liable for any err

Strany 84 - Descriptions

30 Chapter 1E5810A DescriptionE5810A Software/FirmwareUsing E5810 Web AccessSince the E5810 is Web-enabled, you can communicate with the E5810 from a

Strany 85 - Chapter 3 85

Chapter 1 31E5810A DescriptionE5810A Software/FirmwareUsing a Supported Programming LanguageTo use applications that require the Agilent IO Libraries,

Strany 86 - 86 Chapter 3

32 Chapter 1E5810A DescriptionE5810A Software/FirmwareNotes:

Strany 87 - Chapter 3 87

2Installing the E5810A

Strany 88 - 88 Chapter 3

34 Chapter 2Installing the E5810AThis chapter shows suggested steps to install the Agilent E5810A LAN/GPIB Gateway for Windows on LAN networks for Win

Strany 89 - Chapter 3 89

Chapter 2 35Installing the E5810AInstallation FlowchartInstallation FlowchartThis figure shows suggested steps to install and configure an E5810 on an

Strany 90 - 90 Chapter 3

36 Chapter 2Installing the E5810AInstallation FlowchartYou can install the E5810 on an Enterprise (corporate) network that supports Dynamic Host Confi

Strany 91 - Chapter 3 91

Chapter 2 37Installing the E5810ABefore You Install the E5810ABefore You Install the E5810ABefore you connect the E5810A to a network, you should: Ch

Strany 92 - Connected to your E5810

38 Chapter 2Installing the E5810ABefore You Install the E5810ARack-Mount the E5810 (Optional)As desired, you can mount up to two E5810s in a single st

Strany 93 - Instruments

Chapter 2 39Installing the E5810AGetting Network InformationGetting Network InformationThis section gives guidelines to get information about Enterpri

Strany 94 - Instruments Using

4 Declaration of ConformityThe Declaration of Conformity (DoC) for this instrument is available on the Agilent Web site. You can search the DoC by it

Strany 95 - Chapter 3 95

40 Chapter 2Installing the E5810AGetting Network Information E5810 General Information (Completed by E5810 User) (Serial Number and Ethernet (M

Strany 96

Chapter 2 41Installing the E5810AConfiguring the E5810A on a Local NetworkConfiguring the E5810A on a Local NetworkThis step gives guidelines to confi

Strany 97 - Other Web Access Functions

42 Chapter 2Installing the E5810AConfiguring the E5810A on a Local NetworkLocal Network Connections (Multiple PCs can Communicate with the E5810)LAN G

Strany 98 - 98 Chapter 3

Chapter 2 43Installing the E5810AConfiguring the E5810A on a Local NetworkConnecting the E5810A to a Local NetworkThis section shows how to connect th

Strany 99 - Firmware

44 Chapter 2Installing the E5810AConfiguring the E5810A on a Local NetworkE5810 Crossover Cable ConnectionsThis figure shows typical E5810 connections

Strany 100 - Accessible From

Chapter 2 45Installing the E5810AConfiguring the E5810A on a Local NetworkApply Power to the E5810After connecting the E5810 to a Local network, plug

Strany 101

46 Chapter 2Installing the E5810AConfiguring the E5810A on a Local NetworkConfiguring the E5810A for Local Network OperationThis section gives guideli

Strany 102

Chapter 2 47Installing the E5810AConfiguring the E5810A on a Local NetworkConfiguring the E5810 for Enterprise Network OperationYou can check or set E

Strany 103

48 Chapter 2Installing the E5810AConfiguring the E5810A on a Local Network3 Display the Modify Configuration Page. From the Current Configuration of E

Strany 104 - Guidelines

Chapter 2 49Installing the E5810AConfiguring the E5810A on a Local NetworkIf the default password (E5810) is being used, the password is displayed as

Strany 105

5ICES StatementThis ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada.Regulatory MarkingsSafety S

Strany 106 - Using E5810A Web Access

50 Chapter 2Installing the E5810AConfiguring the E5810A on a Local NetworkIP Address AssignmentEnterprise Network Supports DHCPNo action required. The

Strany 107 - Troubleshooting Information

Chapter 2 51Installing the E5810AConfiguring the E5810A on a Local NetworkExample: Configuring the E5810This example shows one way to set various E581

Strany 108

52 Chapter 2Installing the E5810AInstalling the E5810A on an Enterprise NetworkInstalling the E5810A on an Enterprise NetworkThis step gives guideline

Strany 109 - Troubleshooting Overview

Chapter 2 53Installing the E5810AInstalling the E5810A on an Enterprise NetworkAfter connecting the E5810 to the Enterprise network, plug the E5810 AC

Strany 110 - Checking the E5810A

54 Chapter 2Installing the E5810AInstalling the E5810A on an Enterprise NetworkFor example, if the default IP address of 169.254.58.10 is displayed on

Strany 111 - Messages

Chapter 2 55Installing the E5810AInstalling the E5810A on an Enterprise Network2 Display the Current Configuration Page. from the Welcome page, click

Strany 112 - 112 Chapter 4

56 Chapter 2Installing the E5810AInstalling the E5810A on an Enterprise Network

Strany 113 - Defaults

Chapter 2 57Installing the E5810AInstalling the E5810A on an Enterprise Network4 Set E5810 for DHCP Enterprise Network Operation. For an Enterprise ne

Strany 114 - Checking the Network

58 Chapter 2Installing the E5810AVerifying Instrument CommunicationVerifying Instrument CommunicationThe last step in installing and configuring the E

Strany 115 - Cache and Page

Chapter 2 59Installing the E5810AVerifying Instrument CommunicationInstrument Page FunctionsFrom the Find and Control Instruments Connected to your E5

Strany 116

6 WARNINGSThe following general safety precautions must be observed during all phases of operation, service, and repair of this product. Failure to c

Strany 117 - E5810 Operation

60 Chapter 2Installing the E5810AVerifying Instrument CommunicationWhere to Go Next If you want to program instruments from your PC. Go to “Installin

Strany 118 - Set to 0 (infinite)

Chapter 2 61Installing the E5810AInstalling and Configuring Agilent IO Libraries SuiteInstalling and Configuring Agilent IO Libraries SuiteThis sectio

Strany 119 - Client Connections

62 Chapter 2Installing the E5810AInstalling and Configuring Agilent IO Libraries Suite Custom - Select the Custom installation to:a Install the IO Li

Strany 120 - Example: Using the

Chapter 2 63Installing the E5810AInstalling and Configuring Agilent IO Libraries SuiteConfiguring a Remote GPIB InterfaceThis section shows the steps

Strany 121

64 Chapter 2Installing the E5810AInstalling and Configuring Agilent IO Libraries Suitenamed TCPIP0 is configured when you start or refresh Connection

Strany 122 - Message Description

Chapter 2 65Installing the E5810AInstalling and Configuring Agilent IO Libraries SuiteConfiguring a Remote Serial InterfaceThis section shows the step

Strany 123 - Example: Typical

66 Chapter 2Installing the E5810AInstalling and Configuring Agilent IO Libraries Suite4 Specify the TCPIP interface that you wish to use to host this

Strany 124

Chapter 2 67Installing the E5810AInstalling and Configuring Agilent IO Libraries Suite7 To establish communication with a serial instrument connected

Strany 125 - Chapter 4 125

68 Chapter 2Installing the E5810AInstalling and Configuring Agilent IO Libraries SuiteVerifying Communication From Your PCThis section gives guideline

Strany 126 - 126 Chapter 4

Chapter 2 69Installing the E5810AInstalling and Configuring Agilent IO Libraries Suite3 *IDN? is the default command. Click Send & Read to send th

Strany 127 - Checking Instruments

7Documentation HistoryAll Editions and Updates of this manual and their creation date are listed below. The first Edition of the manual is Edition 1.

Strany 128 - 128 Chapter 4

70 Chapter 2Installing the E5810AInstalling and Configuring Agilent IO Libraries SuiteFor information on programming using Agilent VISA, see the Agile

Strany 129 - E5810A Specifications

Chapter 2 71Installing the E5810AInstalling and Configuring Agilent IO Libraries SuiteAddressing Instruments with SICLSICL addresses include the IP ad

Strany 130

72 Chapter 2Installing the E5810AInstalling and Configuring Agilent IO Libraries SuiteNotes:

Strany 131 - Information

3Using E5810A Web Access

Strany 132 - 132 Appendix A

74 Chapter 3Using E5810A Web AccessThis chapter gives guidelines on how to use E5810A Web access, including: Opening Your Web Browser for E5810A Web

Strany 133 - Appendix A 133

Chapter 3 75Using E5810A Web AccessOpening Your Web Browser for E5810A Web AccessOpening Your Web Browser for E5810A Web AccessSince the E5810 is Web-

Strany 134 - Supported Network Protocols

76 Chapter 3Using E5810A Web AccessUsing the Welcome PageUsing the Welcome PageThis section shows the features of the E5810 Welcome page, including th

Strany 135 - Using the Telnet Utility

Chapter 3 77Using E5810A Web AccessUsing the Welcome PageNavigation BarClicking the applicable icon on the Navigation Bar on the left side of the page

Strany 136

78 Chapter 3Using E5810A Web AccessUsing the Welcome PageE5810A Current SettingsThe Current Settings part of the Welcome page displays some of the cur

Strany 137

Chapter 3 79Using E5810A Web AccessUsing the Welcome PageE5810A Support InformationE5810 support information includes Support, Products, and Agilent S

Strany 138 - Exiting the Telnet

8  Corrective actions already tried (see Chapter 4 - Troubleshooting Information for suggested troubleshooting tips)Contacting Agilent  You can rea

Strany 139 - Screen Display

80 Chapter 3Using E5810A Web AccessUsing the Welcome PageE5810A DocumentationYou can click Help to access a complete E5810 help system or click User’s

Strany 140

Chapter 3 81Using E5810A Web AccessViewing and Modifying ConfigurationViewing and Modifying ConfigurationThis section shows how to view and modify (as

Strany 141

82 Chapter 3Using E5810A Web AccessViewing and Modifying ConfigurationModifying E5810A ConfigurationTo modify the current E5810 configuration, from th

Strany 142

Chapter 3 83Using E5810A Web AccessViewing and Modifying Configuration

Strany 143 - Glossary

84 Chapter 3Using E5810A Web AccessViewing and Modifying ConfigurationE5810 Configuration Parameter DescriptionsAn alphabetical listing of E5810 confi

Strany 144

Chapter 3 85Using E5810A Web AccessViewing and Modifying ConfigurationDomain Name Server (DNS) (cont)[0.0.0.0]A DNS Server is an Internet service that

Strany 145 - Glossary 145

86 Chapter 3Using E5810A Web AccessViewing and Modifying ConfigurationDynamic Host Configuration Protocol (DHCP) [ON](cont’d)DHCP OFF: If DHCP is OFF

Strany 146 - 146 Glossary

Chapter 3 87Using E5810A Web AccessViewing and Modifying ConfigurationHostname [None]This value configures the internet domain name for the E5810. Hos

Strany 147 - Glossary 147

88 Chapter 3Using E5810A Web AccessViewing and Modifying ConfigurationIP Address [169.254.58.10]This value is the Internet Protocol (IP) address of th

Strany 148 - 148 Glossary

Chapter 3 89Using E5810A Web AccessViewing and Modifying ConfigurationPassword[E5810]E5810 configuration and instrument control pages are password-pro

Strany 149 - Glossary 149

9Gateway for Windows that is connected to an Enterprise (corporate) network, to a Local Network, or directly to a PC. What’s in This Guide?A listing o

Strany 150 - 150 Glossary

90 Chapter 3Using E5810A Web AccessViewing and Modifying ConfigurationRS-232 Parity [NONE]Parity is used by the RS-232 hardware to verify data transmi

Strany 151 - Glossary 151

Chapter 3 91Using E5810A Web AccessViewing and Modifying ConfigurationUniversal Plug & Play (UPnP)[ON]If Universal Plug & Play (UPnP) is enabl

Strany 152 - 152 Glossary

92 Chapter 3Using E5810A Web AccessFinding and Querying InstrumentsFinding and Querying InstrumentsThis section shows how to find and query GPIB and/o

Strany 153 - Glossary 153

Chapter 3 93Using E5810A Web AccessFinding and Querying InstrumentsFinding InstrumentsThe Instruments Connected column of the page shows the GPIB and/

Strany 154 - 154 Glossary

94 Chapter 3Using E5810A Web AccessFinding and Querying InstrumentsQuerying InstrumentsAfter you have successfully found all connected instruments, yo

Strany 155 - Index 155

Chapter 3 95Using E5810A Web AccessFinding and Querying InstrumentsButton Description*IDN?ID String. Returns the ID string for the selected IEEE-488.2

Strany 156 - 156 Index

96 Chapter 3Using E5810A Web AccessFinding and Querying InstrumentsQuerying Instruments Using the Instrument Command LineFor supported instruments, yo

Strany 157 - Index 157

Chapter 3 97Using E5810A Web AccessOther Web Access FunctionsOther Web Access FunctionsThis section describes four other E5810A Web Access functions:

Strany 158 - 158 Index

98 Chapter 3Using E5810A Web AccessOther Web Access FunctionsUsing Web HelpClicking Help (under E5810 Documentation) displays the Contents page of the

Strany 159 - Agilent Technologies

Chapter 3 99Using E5810A Web AccessOther Web Access FunctionsUpdating E5810A FirmwareThis section gives guidelines to update your E5810 firmware to th

Komentáře k této Příručce

Žádné komentáře