7 Obsolete and Discontinued Commands
:FUNCtion:SOURce
(see page 798)
Command Syntax
:FUNCtion:SOURce <value>
<value> ::= {CHANnel<n> | ADD | SUBTract | MULTiply}
<n>::={1|2|3|4}forthefour channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :FUNCtion:SOURce command is only used when an FFT (Fast Fourier
Transform), DIFF, or INT operation is selected (see
the:FUNCtion:OPERation command for more information about selecting an
operation). The :FUNCtion:SOURce command selects the source for
function operations. Choose CHANnel<n>, or ADD, SUBT, or MULT to
specify the desired source for function DIFFerentiate, INTegrate, and FFT
operations specified by the :FUNCtion:OPERation command.
Query Syntax
:FUNCtion:SOURce?
The :FUNCtion:SOURce? query returns the current source for function
operations.
Return Format
<value><NL>
<value> ::= {CHAN<n> | ADD | SUBT | MULT}
<n>::={1|2|3|4}forthefour channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
See Also "Introduction to :FUNCtion Commands" on page 278
":FUNCtion:OPERation" on page 285
NOTE
The :FUNCtion:SOURce command is an obsolete command provided for compatibility to
previous oscilloscopes. Use the :FUNCtion:SOURce1 command (see page 289) instead.