 Agilent Technologies Low-Profile Modular Power System Series N6700 User’s Guide

Strany 2 - Legal Notices

1 Quick Reference 10 Series N6700 User’s Guide Model Differences Feature DC Power High-Performance Precision (● = available) N673xB, N674xB, N67

Strany 3 - Safety Notices

Appendix A Specifications 100 Series N6700 User’s Guide Agilent N6700B, N6701A, N6702A MPS Mainframes Supplemental Characteristics N6700B, N670

Strany 4 - In this Book

Specifications Appendix A Series N6700 User’s Guide 101 Supplemental Characteristics (continued) N6700B, N6701A, N6702A Environmental Conditions

Strany 5 - Contents

Appendix A Specifications 102 Series N6700 User’s Guide Outline Diagram 44.45 mm1.75".432.5 mm17.03"549.7 mm21.64"482.6 mm19.00&q

Strany 6 - Updates

Series N6700 User’s Guide 103 Appendix B Using the Digital Port Digital Control Port ...

Strany 7 - Quick Reference

Appendix B Using the Digital Port 104 Series N6700 User’s Guide Digital Control Port An 8-pin connector and a quick-disconnect connector plug are

Strany 8 - Output Features

Using the Digital Port Appendix B Series N6700 User’s Guide 105 Configuring the Digital Control Port Bi-directional Digital I/O Each of the seven

Strany 9 - System Features

Appendix B Using the Digital Port 106 Series N6700 User’s Guide Digital Input Each of the seven pins can be configured as digital input only. The

Strany 10 - Model Differences

Using the Digital Port Appendix B Series N6700 User’s Guide 107 Fault Output Pins 1 and 2 can be configured as a fault-output pair. The polarity o

Strany 11 - The Rear Panel – At a Glance

Appendix B Using the Digital Port 108 Series N6700 User’s Guide Fault/Inhibit System Protection The following figure illustrates some ways that y

Strany 12 - = activity on interface)

Series N6700 User’s Guide 109 Appendix C Power Allocation Power Limit Operation ...

Strany 13 - Help Error

Quick Reference 1 Series N6700 User’s Guide 11 The Front Panel – At a Glance Display Turns off after 1 hour of inactivity. Press any key to restor

Strany 14 - Front Panel Menu Reference

Appendix C Power Allocation 110 Series N6700 User’s Guide Power Limit Operation Mainframe Power Limit If the combined power drawn from all of the

Strany 15 - Quick Reference 1

Power Allocation Appendix C Series N6700 User’s Guide 111 For Agilent Models N678xA SMU, the power limit function does not apply. Module Power Al

Strany 17 - SCPI Command Description

Series N6700 User’s Guide 113 Appendix D Output On/Off Synchronization Synchronizing Output Turn-on Delays ...

Strany 18 - 1 Quick Reference

Appendix D Output On/Off Synchronization 114 Series N6700 User’s Guide Synchronizing Output Turn-on Delays All N6700 Power Modules that are insta

Strany 19

Output On/Off Synchronization Appendix D Series N6700 User’s Guide 115 By setting the common delay offset to be greater than or equal to the large

Strany 20

Appendix D Output On/Off Synchronization 116 Series N6700 User’s Guide 2. Specify which Output Channels will be Synchronized Select the output c

Strany 21

Output On/Off Synchronization Appendix D Series N6700 User’s Guide 117 Synchronizing Multiple Mainframes The output turn-on synchronization functi

Strany 22 - *RST Settings

Appendix D Output On/Off Synchronization 118 Series N6700 User’s Guide Only two of the digital connector pins on each mainframe can be configured

Strany 23 - Installation

Series N6700 User’s Guide 119 Appendix E Source Operating Modes Single Quadrant Operation ...

Strany 24 - General Information

1 Quick Reference 12 Series N6700 User’s Guide Front Panel Display – At a Glance Single-channel view Voltage measurement Bar indi

Strany 25 - Inspecting the Unit

Appendix E Source Operating Modes 120 Series N6700 User’s Guide Single Quadrant Operation The Agilent N6700 Modular Power System can operate in e

Strany 26 - Installing the Unit

Source Operating Modes Appendix E Series N6700 User’s Guide 121 Autoranging NOTE Autoranging only applies to Agilent N675xA and N676xA power modul

Strany 27 - Power Module Installation

Appendix E Source Operating Modes 122 Series N6700 User’s Guide Agilent N678xA Multi-Quadrant Operation Agilent Models N678xA SMU can be operated

Strany 28 - Rack Installation

Source Operating Modes Appendix E Series N6700 User’s Guide 123 When the output current reaches either the positive or negative current limit, the

Strany 29 - 400 Hz Operation

Appendix E Source Operating Modes 124 Series N6700 User’s Guide The heavy solid line illustrates the locus of possible operating points as a func

Strany 30 - Connecting the Line Cord

Index A Admin menu, password ... 59 airflow ...

Strany 31 - Connecting the Outputs

Appendix E Source Operating Modes 126 Series N6700 User’s Guide front panel menu exiting ...

Strany 32 - Wire Size

Source Operating Modes Appendix E Series N6700 User’s Guide 127 state ...

Strany 33 - < 15 cm

Appendix E Source Operating Modes 128 Series N6700 User’s Guide returning voltage data ... 82 sett

Strany 34 - Guard Connection

Quick Reference 1 Series N6700 User’s Guide 13 Operating status indicators OFF = the output is off CV = the output is in constant voltage mode CC

Strany 35 - Multiple Loads

1 Quick Reference 14 Series N6700 User’s Guide Front Panel Menu Reference NOTE Menu commands that appear grayed-out on the front panel are either

Strany 36 - Remote Sense Connections

Quick Reference 1 Series N6700 User’s Guide 15 Menu Command Control Description System IO LAN ActiveSettings Displays the LAN interface settings

Strany 37 - Output Noise Considerations

1 Quick Reference 16 Series N6700 User’s Guide SCPI Command Summary Subsystem Commands NOTE Some [optional] commands have been included for clari

Strany 38 - Parallel Connections

Quick Reference 1 Series N6700 User’s Guide 17 SCPI Command Description FETCh[:SCALar] (continued) :POWer [:DC]? (@ch

Strany 39 - Effect on Specifications

1 Quick Reference 18 Series N6700 User’s Guide SCPI Command Description OUTPut [:STATe] <Bool> [,NORelay], (@chanlist) Enables/disabl

Strany 40 - Series Connections

Quick Reference 1 Series N6700 User’s Guide 19 SCPI Command Description SENSe (continued) :SWEep (Sweep commands only on N676xA, N678xA SMU

Strany 41 - Setting the Outputs

2 Series N6700 User’s Guide Legal Notices © Agilent Technologies, Inc. 2006-2012 No part of this document may be photocopied, reproduced, or transl

Strany 42

1 Quick Reference 20 Series N6700 User’s Guide SCPI Command Description [SOURce:]LIST:TOUTput (continued) :DWELl <NRf> {,<NR

Strany 43

Quick Reference 1 Series N6700 User’s Guide 21 SCPI Command Description STATus :OPERation [:EVENt]? (@chanlist) Returns the

Strany 44 - CAUTION

1 Quick Reference 22 Series N6700 User’s Guide Common Commands Command Description Command Description *CLS Clear status *RDT? Return output c

Strany 45 - Getting Started

Series N6700 User’s Guide 23 2 Installation General Information ...

Strany 46 - Selecting an Output Channel

2 Installation 24 Series N6700 User’s Guide General Information Models Agilent Model Description N6700B / N6701A / N6702A 400 W / 600 W / 1200W

Strany 47 - Enabling the Output

Installation 2 Series N6700 User’s Guide 25 Items Supplied Mainframe Items Description Part Number Power Cord A power cord suitable for your lo

Strany 48 - Using the Front Panel Menu

2 Installation 26 Series N6700 User’s Guide Installing the Unit Safety Considerations This power system is a Safety Class 1 instrument, which mea

Strany 49 - In Case of Trouble

Installation 2 Series N6700 User’s Guide 27 Power Module Installation NOTE The information in this section applies if you have purchased an N6700

Strany 50 - Connecting to the Interfaces

2 Installation 28 Series N6700 User’s Guide Step 3. Use a T10 Torx driver and install the screws at each end of the power module. Because the RF

Strany 51 - LAN Interface

Installation 2 Series N6700 User’s Guide 29 Step 2. Install the two front ears and the two rear extender supports on the instrument as shown in t

Strany 52 - Connecting to a Private LAN

Series N6700 User’s Guide 3 Safety Notices The following general safety precautions must be observed during all phases of operation of this instrume

Strany 53

2 Installation 30 Series N6700 User’s Guide Connecting the Line Cord WARNING FIRE HAZARD Use only the power cord that was supplied with your ins

Strany 54 - Modifying the LAN Settings

Installation 2 Series N6700 User’s Guide 31 Connecting the Outputs WARNING SHOCK HAZARD Turn off AC power before making rear panel connections. A

Strany 55

2 Installation 32 Series N6700 User’s Guide Wire Size WARNING FIRE HAZARD Select a wire size large enough to carry short-circuit current without

Strany 56

Installation 2 Series N6700 User’s Guide 33 Agilent N678xA SMU Wiring Requirements NOTE Because of the effect of wire inductance, the wire length

Strany 57 - Communicating Over the LAN

2 Installation 34 Series N6700 User’s Guide To minimize inductance, the width (w) of the traces should be at least as great as the thickness of t

Strany 58 - Using Sockets

Installation 2 Series N6700 User’s Guide 35 Multiple Loads If you are using local sensing and are connecting multiple loads to one output, connect

Strany 59 - Securing the Interfaces

2 Installation 36 Series N6700 User’s Guide Remote Sense Connections WARNING SHOCK HAZARD Turn off AC power before making or changing rear panel

Strany 60

Installation 2 Series N6700 User’s Guide 37 Open Sense Leads The sense leads are part of the output's feedback path. Connect them in such a w

Strany 61 - Operating the Power System

2 Installation 38 Series N6700 User’s Guide Parallel Connections CAUTION Only connect outputs that have identical voltage and current ratings in

Strany 62 - Programming the Output

Installation 2 Series N6700 User’s Guide 39 Grouping the Outputs Once outputs have been connected in parallel, they can be configured or “grouped”

Strany 63 - Set the Output Mode

4 Series N6700 User’s Guide In this Book Specific chapters in this manual contain the following information:  Quick Reference – Chapter 1 is a q

Strany 64 - Enable the Output

2 Installation 40 Series N6700 User’s Guide Series Connections WARNING SHOCK HAZARD Floating voltages must not exceed 240 VDC. No output termina

Strany 65 - Program the Output Relays

Installation 2 Series N6700 User’s Guide 41 Setting the Outputs Outputs connected together in series cannot be grouped. To program outputs connec

Strany 66 - Set the Output Bandwidth

2 Installation 42 Series N6700 User’s Guide Additional Load Considerations Response Time with an External Capacitor When programming with an exte

Strany 67 - Set the Output Turn-Off Mode

Installation 2 Series N6700 User’s Guide 43 created by the low side of the scope probe, which is connected to the load circuit common and also to

Strany 68 - Synchronizing Output Steps

2 Installation 44 Series N6700 User’s Guide Agilent N6781A Auxiliary Voltage Measurement Input The auxiliary voltage measurement input is located

Strany 69

Series N6700 User’s Guide 45 3 Getting Started Turning the Unit On ...

Strany 70 - Trigger the Output

3 Getting Started 46 Series N6700 User’s Guide Turning the Unit On After you have connected the line cord, turn the unit on with the front panel

Strany 71 - Generate Trigger Out Signals

Getting Started 3 Series N6700 User’s Guide 47 Entering a Current Limit Setting Method 1 – Use the Navigation and Arrow Keys Navigation Keys Sel U

Strany 72 - Programming Output Lists

3 Getting Started 48 Series N6700 User’s Guide Using the Front Panel Menu The front panel command menu lets you access most of the power system’s

Strany 73

Getting Started 3 Series N6700 User’s Guide 49 Sel 4 4 Enter The command menu is now at the function control level. This is the lowest lev

Strany 74

Series N6700 User’s Guide 5 Contents 1 – Quick Reference ...

Strany 75 - 0 2 3 4 5

3 Getting Started 50 Series N6700 User’s Guide Connecting to the Interfaces The Agilent N6700 MPS supports GPIB, LAN, and USB interfaces. All thr

Strany 76 - Trigger at EOST

Getting Started 3 Series N6700 User’s Guide 51 6 You can now use Interactive IO within the Connection Expert to communicate with your instrument,

Strany 77 - Making Measurements

3 Getting Started 52 Series N6700 User’s Guide Connecting to a Site LAN A site LAN is a local area network in which LAN-enabled instruments and c

Strany 78 - MEAS:VOLT? (@1)

Getting Started 3 Series N6700 User’s Guide 53 1 If you have not already done so, install the Agilent IO Libraries Suite from the Automation-Read

Strany 79 - Using the Digitizer

3 Getting Started 54 Series N6700 User’s Guide Viewing the Active LAN Settings To view the currently active LAN settings, press the Menu key, the

Strany 80 - Seamless Measurements

Getting Started 3 Series N6700 User’s Guide 55 Default Gateway This value is the IP Address of the default gateway that allows the instrument to c

Strany 81 - Specify a Window Function

3 Getting Started 56 Series N6700 User’s Guide DNS Select DNS to configure the Domain Name System (DNS) setup of the instrument. DNS is an intern

Strany 82 - Retrieve array data

Getting Started 3 Series N6700 User’s Guide 57 Communicating Over the LAN The Agilent IO Libraries Suite along with instrument drivers for specifi

Strany 83 - Capture Pre-trigger Data

3 Getting Started 58 Series N6700 User’s Guide 3 Click on the Browser Web Control button in the navigation bar on the left to begin controlling

Strany 84 - SENS:SWE:OFFS:POIN 100,(@1)

Getting Started 3 Series N6700 User’s Guide 59 Securing the Interfaces Enable/Disable the USB, LAN, and Web Server The USB interface, LAN interfac

Strany 85 - Trigger the Measurement

6 Series N6700 User’s Guide External Data Logging ... 91 System-

Strany 86 - Fetch the Measurement

3 Getting Started 60 Series N6700 User’s Guide Factory-shipped non-volatile LAN settings Get IP Address Automatic Dynamic DNS naming service En

Strany 87

Series N6700 User’s Guide 61 4 Operating the Power System Programming the Output ...

Strany 88 - CURR:PROT:DEL:STAR SCH, (@1)

4 Operating the Power System 62 Series N6700 User’s Guide Programming the Output Select a Channel View Front Panel: SCPI Command: Press the Me

Strany 89 - Output Watchdog Timer

Operating the Power System 4 Series N6700 User’s Guide 63 Set the Output Current Front Panel: SCPI Command: Press the Current key. Enter a value

Strany 90 - OUTP:PROT:WDOG:DEL 600

4 Operating the Power System 64 Series N6700 User’s Guide Front Panel: SCPI Command: Select Output\Mode. Select either Voltage priority or Curre

Strany 91 - External Data Logging

Operating the Power System 4 Series N6700 User’s Guide 65 Sequence Multiple Outputs Turn-on and turn-off delays control the power-up and power-dow

Strany 92

4 Operating the Power System 66 Series N6700 User’s Guide Front Panel: SCPI Command: Not Available To leave the relays closed when output 1 is

Strany 93

Operating the Power System 4 Series N6700 User’s Guide 67 If capacitive loads cause the output to oscillate on the default (Low bandwidth) or any

Strany 94 - Terminate the Measurement

4 Operating the Power System 68 Series N6700 User’s Guide Synchronizing Output Steps The transient system lets you step the output voltage and cu

Strany 95 - System-Related Operations

Operating the Power System 4 Series N6700 User’s Guide 69 Select the Transient Trigger Source NOTE An immediate trigger command either from the f

Strany 96 - Output Groups

Series N6700 User’s Guide 7 1 Quick Reference The Agilent N6700 Modular Power System – At a Glance ... 8 The Front Panel – At

Strany 97 - Front Panel Keys

4 Operating the Power System 70 Series N6700 User’s Guide It takes a few milliseconds for the instrument to be ready to receive a trigger signal

Strany 98 - Front Panel Display

Operating the Power System 4 Series N6700 User’s Guide 71 You can test the TRAN_active bit in the operation status register to know when the trans

Strany 99 - Specifications

4 Operating the Power System 72 Series N6700 User’s Guide Programming Output Lists NOTE The Output List function described in this section is not

Strany 100 - Supplemental Characteristics

Operating the Power System 4 Series N6700 User’s Guide 73 Program an Output Pulse or Pulse Train The following procedure shows how to generate an

Strany 101

4 Operating the Power System 74 Series N6700 User’s Guide Step 5. To generate a pulse train, you can simply repeat the pulse as needed. For exam

Strany 102 - Outline Diagram

Operating the Power System 4 Series N6700 User’s Guide 75 Program an Arbitrary List The following procedure shows how to generate the list of volt

Strany 103 - Using the Digital Port

4 Operating the Power System 76 Series N6700 User’s Guide Front Panel: SCPI Command: Select Transient\List\Pace. Select Dwell-paced. Press Selec

Strany 104 - Digital Control Port

Operating the Power System 4 Series N6700 User’s Guide 77 Making Measurements Each output channel has its own measurement capability. The output v

Strany 105 - Bi-directional Digital I/O

4 Operating the Power System 78 Series N6700 User’s Guide Simultaneous Voltage and Current Measurements Some models have simultaneous voltage and

Strany 106 - Digital Input

Operating the Power System 4 Series N6700 User’s Guide 79 Using the Digitizer NOTE The Digitizer functions described in this section are not avail

Strany 107 - Inhibit Input

1 Quick Reference 8 Series N6700 User’s Guide The Agilent N6700 Modular Power System – At a Glance The Agilent N6700 Modular Power System is a co

Strany 108 - Output State

4 Operating the Power System 80 Series N6700 User’s Guide Seamless Measurements Seamless voltage and current measurement autoranging is available

Strany 109 - Power Allocation

Operating the Power System 4 Series N6700 User’s Guide 81 Time interval values from 10.24 up to 20.48 microseconds are rounded to the nearest 10.2

Strany 110 - Power Limit Operation

4 Operating the Power System 82 Series N6700 User’s Guide Front Panel: SCPI Command: Not Available To measure the high level of a pulse: MEAS

Strany 111 - Module Power Allocation

Operating the Power System 4 Series N6700 User’s Guide 83 Synchronizing Digitizer Measurements Use the measurement trigger system to synchronize t

Strany 112

4 Operating the Power System 84 Series N6700 User’s Guide To offset the beginning of the acquisition buffer relative to the acquisition trigger,

Strany 113 - Appendix D

Operating the Power System 4 Series N6700 User’s Guide 85 Initiate the Measurement Trigger System Next, you must initiate or enable the measureme

Strany 114

4 Operating the Power System 86 Series N6700 User’s Guide The following commands return the trigger system to the idle state: Front Panel: SCPI

Strany 115 - Procedure

Operating the Power System 4 Series N6700 User’s Guide 87 Using the Protection Functions Each output has independent protection functions. A front

Strany 116

4 Operating the Power System 88 Series N6700 User’s Guide Front Panel: SCPI Command: Select Protect\OVP. Enter a value in the OVP level box and

Strany 117

Operating the Power System 4 Series N6700 User’s Guide 89 Factors that influence how long the settings change or output load change may last inclu

Strany 118 - OFF Couple

Quick Reference 1 Series N6700 User’s Guide 9 Output autoranging capability Available on Agilent N676xA and N675xA power modules. Autoranging supp

Strany 119 - Source Operating Modes

4 Operating the Power System 90 Series N6700 User’s Guide Front Panel: SCPI Command: Select Protect\Wdog Check Enable Watchdog to enable the wa

Strany 120 - Downprogrammer

Operating the Power System 4 Series N6700 User’s Guide 91 External Data Logging NOTE The external data log function is only available on mainframe

Strany 121 - Downprogramming

4 Operating the Power System 92 Series N6700 User’s Guide If a power module has simultaneous measurements (see chapter 1, “Model Differences”), y

Strany 122 - Voltage Priority Mode

Operating the Power System 4 Series N6700 User’s Guide 93 102.4 microseconds: 204.8 microseconds: 409.6 microseconds: 409.6 microseconds: 1 para

Strany 123 - Current Priority Mode

4 Operating the Power System 94 Series N6700 User’s Guide Initiate and Trigger the Data Logger When the power system is turned on, the trigger s

Strany 124

Operating the Power System 4 Series N6700 User’s Guide 95 System-Related Operations Self-Test A power-on self-test occurs automatically when you t

Strany 125

4 Operating the Power System 96 Series N6700 User’s Guide Output Groups NOTE Output grouping does not apply to Agilent Models N678xA SMU. Output

Strany 126

Operating the Power System 4 Series N6700 User’s Guide 97 Front Panel Keys Lockout You can lock the front panel keys to prevent unwanted control o

Strany 127

4 Operating the Power System 98 Series N6700 User’s Guide Front Panel Display Screen Saver The power system has a front panel screen saver that s

Strany 128

Series N6700 User’s Guide 99 Appendix A Specifications Agilent N6700B, N6701A, N6702A MPS Mainframes ......... 100 This appen