Chapter 7 7-17
Programming Examples
Measurement Setup Examples
‘***************************************************************************
‘* hp875x Instrument Driver EXAMPLE #1A *
‘* *
‘* This program demonstrates setup of various measurement parameters such *
‘* as start frequency, stop frequency, etc. The program first selects one *
‘* type of measurement to be viewed using dual-channel display format. *
‘* The specified start and stop frequencies are then programmed and the *
‘* analyzer display is autoscaled. The program concludes by displaying *
‘* four types of measurements simultaneously. *
‘***************************************************************************
Private Sub cmdExecute_Click()
Dim vi As Long
Dim err_status As Long
Dim nwa As String
Dim retString As String
Dim msg As String
Dim f_start As Double
Dim f_stop As Double
Dim iRetVal As Integer
Dim reply As Integer
lstText.Clear
lstText.AddItem “Example 1a --”
lstText.AddItem “This program demonstrates setup of various measurement parameters
such
lstText.AddItem “as start frequency, stop frequency, etc. The program first selects
one”
lstText.AddItem “type of measurement to be viewed using dual-channel display format.
lstText.AddItem “The specified start and stop frequencies are then programmed and the”
lstText.AddItem “analyzer display is autoscaled. The program concludes by displaying”
lstText.AddItem “four types of measurements simultaneously.
lstText.AddItem ““
nwa =GPIB0::16::INSTR”
‘ Initialize the instrument
Call initialize(nwa, VI_FALSE, VI_TRUE, vi)
‘ Set the timeout to 3000 msec (3 sec)
err_status = hp875x_timeOut(vi, 3000)
Call checkErr(vi, err_status)
‘ Set up measurement and display
‘ Channel 1
err_status = hp875x_channelSelect(vi, hp875x_CH1)
Call checkErr(vi, err_status)
‘ Turn auxiliary channel off.
err_status = hp875x_auxChannel(vi, hp875x_CH1, hp875x_OFF)
Call checkErr(vi, err_status)
‘ Return Loss measurement, no parameter conversion
‘ For 8719ET/8720ET/8722ET/8753ET, hp875x_S_PAR11 is interpreted as hp875x_REFL
err_status = hp875x_measType(vi, hp875x_S_PAR11, hp875x_CONV_OFF)
Call checkErr(vi, err_status)
‘ Log magnitude display
err_status = hp875x_displaySelect(vi, hp875x_CH1, hp875x_DISP_DATA, hp875x_DISP_LOGM)
Zobrazit stránku 382
1 2 ... 378 379 380 381 382 383 384 385 386 387 388 ... 545 546

Komentáře k této Příručce

Žádné komentáře

Case-mate Non manuels d'utilisation

La liste de Case-mate Non produits contient 1 manuels d'utilisation pour les modèles 1. Tous les guides d'utilisation en format pdf peuvent être téléchargés ou consultés en ligne.

Cliquez sur un alphabet ci-dessous pour faire défiler la liste complète des modèles commençant par cette lettre

Modèles Type de document
CM010092
Fiche technique   Case-mate iPhone 3G/3GS Battery Case, 6 pages