6
87050A opt H Family of test sets
1
Designed to work with the 875x family of network analyzers.
Frequency range: 30 kHz to 6 GHz Switch type: Mechanical
2
Connectors: Type-N (f) Switching speed: 60 ms
Impedance: 50 ohm I/O control: GPIB and Parallel
Option Designed for:
3
Ports Raw (uncorrected) Raw (uncorrected) Test set type
(Works with:) return loss insertion loss
H06
875x
6
≥ 25 dB, 30 kHz to 1.3 GHz ≤ 1 dB, 30 kHz to 1.3 GHz
H12
(871x)
12
≥ 16 dB, 1.3 to 3.0 GHz ≤ 1.75 dB, 1.3 to 3.0 GHz
Full crossbar
H16
(PNA)
16
≥ 12 dB, 3.0 to 6.0 GHz ≤ 2.5 dB, 3.0 to 6.0 GHz
H24 24
87050A opt K Family of test sets
1
Designed to work with the 872x family of network analyzers.
Frequency range: 50 MHz to 20 GHz Switch type: Mechanical
2
Connectors: 3.5 mm (f) Switching speed: 60 ms
Impedance: 50 ohm I/O control: GPIB and Parallel
Option Designed for:
3
Ports Raw (uncorrected) Raw (uncorrected) Test set type
(Works with:) return loss insertion loss
K06
872x
6 ≥ 24 dB, 50 MHz to 1.3 GHz ≤ 2.5 dB, 50 MHz to 6.0 GHz
Full crossbar
K12
(875x)
12 ≥ 20 dB, 1.3 to 3.0 GHz ≤ 3.5 dB, 60 to 12.4 GHz
K16
(PNA)
16 ≥ 14 dB, 3.0 to 6.0 GHz ≤ 4.5 dB, 12.4 to 20 GHz
K22 22 ≥ 12 dB, 6.0 o 12.4 GHz SCMM
4
K24 24 ≥ 8 dB, 12.4 to 20 GHz Full crossbar
87050E Family of test sets
Designed to work with the 871x family of network analyzers.
Special calibration features include Test Set Cal to reduce redundant connections during calibration and SelfCal to reduce the effects of test-system drift.
Frequency range: 3 MHz to 2.2 GHz (3 GHz Typ) Switch type: Solid state
Connectors: Type-N (f) Switching speed: 60 ms
Impedance: 50 ohm I/O control: GPIB
5
and Parallel
Option Designed for: Ports System
6
System
6
Test set type
source match load match
004 4 37 dB, 3 MHz to1.3 GHz 47 dB, 3 MHz to 1.3 GHz
Full crossbar
008 871x 8 35 dB, 1.3 GHz to 2.2 GHz 40 dB, 1.3 GHz to 2.2 GHz
012 12
Option Designed for: Ports Raw (uncorrected) Raw (uncorrected) Test set type
return loss insertion loss
H08
8753D/E/ET/ES
7
8 ≥ 12 dB, 3 MHz to 2.2 GHz ≤ 7.5 dB, 3 MHz to 1.3 GHz
Full crossbar
H12 12 ≤ 9.5 dB, 1.3 MHz to 2.2 GHz
87075C Family of test sets
Designed to work with the 8712 family of network analyzers.
Special calibration features include Test Set Cal to reduce redundant connections during calibration and SelfCal to reduce the effects of test-system drift.
Frequency range: 3 MHz to 1.3 GHz Switch type: Solid state
Connectors: Type-N (f) Switching speed: 60 ms
Impedance: 75 ohm I/O control: GPIB
5
and Parallel
Option Designed for: Ports Raw (uncorrected) Raw (uncorrected) Test set type
(Works with:) return loss insertion loss
006 8712ET/ES 6 ≥ 15 dB, 3 MHz to 1.3 GHz Refl. to Port N Port N to Trans.
Full crossbar
012 12 ≤6 dB ≤10 dB
H08
8753D/E/ET/ES
7 8
H12 12
1 The 87050A family of test sets do not include control interface. Contact your local Agilent Field Engineer for hardware and software control integration solutions.
2 Life time of mechanical switches are specified at 5 million cycles
3 Designed for/(Works with:) Test sets that are used with analyzers other then the ones that they are designed for may require extra cabling or custom designed software
controls. See data sheets for particular details.
4 Single connection multiple measurements test set
5 H opts add GPIB interface needed for use with 8753x
6 Specified system performance of 8714 with 87050E test set calibrated with 85032B two-port calibration.
See data sheet for complete details, literature number 5968-4764E
7 Test Set Cal and SelfCal are not supported.
Test sets by family