Agilent Technologies 1100 Series Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Sítě Agilent Technologies 1100 Series. Agilent Technologies 1100 Series Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 196
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Capillary LC System

s1Agilent 1100 Series Capillary LC SystemSystem Manual

Strany 2

x 1100 Series Capillary LC System ManualcontentsASafety InformationGeneral 176Operation 176Safety Symbols 177Lithium Batteries Information 178Danish I

Strany 3 - In This Manual…

90 1100 Series Capillary LC System Manual5 Parts and MaterialsTabl e 32 Sampling unit for the micro autosamplerItem Description Part NumberMicro sampl

Strany 4

1100 Series Capillary LC System Manual 91Parts and Materials 5Micro Analytical Head AssemblyTabl e 33 Micro analytical head assemblyItem Description P

Strany 5 - Contents

92 1100 Series Capillary LC System Manual5 Parts and MaterialsMicro Injection Valve AssemblyTabl e 34 Micro injection valve assemblyItem Description P

Strany 6

1100 Series Capillary LC System Manual 93Parts and Materials 5Thermostatted Micro Autosampler Cover PartsTabl e 35 Thermostatted micro autosampler cov

Strany 7

94 1100 Series Capillary LC System Manual5 Parts and MaterialsVial TraysTabl e 36 Thermostatted autosampler vial trays and tray baseItem Description P

Strany 8

1100 Series Capillary LC System Manual 95Parts and Materials 5Thermostatted Column CompartmentTable 37 gives an overview over the main assemblies of t

Strany 9

96 1100 Series Capillary LC System Manual5 Parts and MaterialsFigure 24 Thermostatted column compartment main assemblies1231456789

Strany 10

1100 Series Capillary LC System Manual 97Parts and Materials 5Micro Column Switching ValveTabl e 38 Micro column switching valveItem Description Part

Strany 11 - Agilent Technologies

98 1100 Series Capillary LC System Manual5 Parts and MaterialsThermostatted Column Compartment Sheet Metal KitTabl e 39 Thermostatted column compartme

Strany 12 - Site Requirements

1100 Series Capillary LC System Manual 99Parts and Materials 5Thermostatted Column Compartment Cover PartsTabl e 40 Thermostatted column compartment c

Strany 13 - Environment

1Agilent 1100 Series Capillary LC SystemSystem ManualAgilent Technologies1Installing your Capillary LC SystemSite Requirements 2Physical Specification

Strany 14 - Physical Specifications

100 1100 Series Capillary LC System Manual5 Parts and MaterialsThermostatted Column Compartment Leak PartsTabl e 41 Thermostatted column compartment l

Strany 15

1100 Series Capillary LC System Manual 101Parts and Materials 5Diode Array DetectorTable 42 gives an overview over the main assemblies of the diode ar

Strany 16 - System Installation Process

102 1100 Series Capillary LC System Manual5 Parts and MaterialsFigure 29 Diode array detector main assemblies641723985

Strany 17

1100 Series Capillary LC System Manual 103Parts and Materials 5DAD - Optical Unit AssemblyTable 43 gives an overview over optical unit parts:. The ite

Strany 18

104 1100 Series Capillary LC System Manual5 Parts and MaterialsFigure 30 Optical Unit Parts143572137141561089111216

Strany 19

1100 Series Capillary LC System Manual 105Parts and Materials 5500 nl Flow CellFigure 31 500 nl Flow CellTabl e 44 500 nl Flow Cell - partsItem Descri

Strany 20

106 1100 Series Capillary LC System Manual5 Parts and Materials12 Cell Seal Assembly 10 mm see kit below13 Quartz Cell Body 10 mm G1315-8000114 Handle

Strany 21

1100 Series Capillary LC System Manual 107Parts and Materials 5Fan Assembly PartsTabl e 45 Fan assembly partsItem Description Part Number1 Heater asse

Strany 22

108 1100 Series Capillary LC System Manual5 Parts and MaterialsHolmium Oxide FilterTabl e 46 Holmium oxide filter assembly partsItem Description Part

Strany 23 - Install the Solvent Cabinet

1100 Series Capillary LC System Manual 109Parts and Materials 5Diode Array Detector Cover PartsTabl e 47 Diode array detector cover partsItem Descript

Strany 24

2 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemSite RequirementsA suitable environment is important to ensure optimum pe

Strany 25

110 1100 Series Capillary LC System Manual5 Parts and MaterialsCommon PartsThis chapter shows the parts identification of the common parts like rear p

Strany 26 - Micro Well-plate Sampler)

1100 Series Capillary LC System Manual 111Parts and Materials 5Rear panelTabl e 49 Rear panelItem Description Part Number1 Standoff — remote connector

Strany 27

112 1100 Series Capillary LC System Manual5 Parts and MaterialsPower and Status Light PipesTabl e 50 Power and status light pipesItem Description Part

Strany 28

1100 Series Capillary LC System Manual 113Parts and Materials 5Leak PartsTabl e 51 Leak partsItem Description Part Number1 Holder, leak funnel 5041-83

Strany 29

114 1100 Series Capillary LC System Manual5 Parts and MaterialsFoam partsSheet metal kitTabl e 52 Foam partsDescription Part numberFoam kit for the ca

Strany 30

1100 Series Capillary LC System Manual 115Parts and Materials 5Micro Degasser Accessory KitCapillary Pump Preventive Maintenance Kit G1376-68710Tabl e

Strany 31

116 1100 Series Capillary LC System Manual5 Parts and MaterialsCapillary Pump Accessory KitTabl e 56 Capillary pump accessory kit G1376-68705Descripti

Strany 32

1100 Series Capillary LC System Manual 117Parts and Materials 5Micro Well-plate Sampler Accessory Kit G1377-68705Tabl e 57 Micro well-plate sampler ac

Strany 33

118 1100 Series Capillary LC System Manual5 Parts and MaterialsThermostatted Micro Autosampler Accessory KitTabl e 58 Thermostatted micro autosampler

Strany 34 - Purging the Pump

1100 Series Capillary LC System Manual 119Parts and Materials 5Column Compartment with Micro Column Selection Valve Accessory KitTabl e 59 Column comp

Strany 35

1100 Series Capillary LC System Manual 3Installing your Capillary LC System 1Bench SpaceThe modules dimensions and weight (see Table 2 on page 5) allo

Strany 36 - Inject the Check-out Sample

120 1100 Series Capillary LC System Manual5 Parts and MaterialsDAD Accessory KitTabl e 60 DAD accessory kit G1315-68705Description Part NumberAccessor

Strany 37 - Procedure

1100 Series Capillary LC System Manual 121Parts and Materials 5CablesTable 61 offers an overview over all cables supplied:WARNINGNever use cables othe

Strany 38

122 1100 Series Capillary LC System Manual5 Parts and MaterialsBCD cables 3392/3 integrators 18594-605103396 integrator 03396-60560General purpose (sp

Strany 39 - Optimizing Performance

1100 Series Capillary LC System Manual 123Parts and Materials 5Analog CablesOne end of these cables provides a BNC connector to be connected to Agilen

Strany 40 - Pump issues

124 1100 Series Capillary LC System Manual5 Parts and MaterialsRemote CablesOne end of these cables provides a Agilent Technologies APG (Analytical Pr

Strany 41 - Fused Silica Capillary issues

1100 Series Capillary LC System Manual 125Parts and Materials 5Tabl e 66 Agilent 1100 to 3390 integratorsConnector01046-60203Pin3390PinAgilent 1100Sig

Strany 42 - DAD issues

126 1100 Series Capillary LC System Manual5 Parts and MaterialsTabl e 68 Agilent 1100 to 3394 integratorsConnector01046-60210Pin3394PinAgilent 1100Sig

Strany 43

1100 Series Capillary LC System Manual 127Parts and Materials 5Agilent 1100 to 3396 Series II / 3395A IntegratorsUse the cable 03394-60600 and cut pin

Strany 44

128 1100 Series Capillary LC System Manual5 Parts and MaterialsTabl e 70 Agilent 1100 to 3396 Series III / 3395B integratorsConnector03396-61010Pin33X

Strany 45 - Cleaning the Solvent Filters

1100 Series Capillary LC System Manual 129Parts and Materials 5Tabl e 72 Agilent 1100 to HP 1090 LC, HP 1040 DAD or signal distribution moduleConnecto

Strany 46

4 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemPhysical SpecificationsTabl e 1 Common Physical SpecificationsType Specif

Strany 47 - When to use Alternative Seals

130 1100 Series Capillary LC System Manual5 Parts and MaterialsBCD CablesOne end of these cables provides a 15-pin BCD connector to be connected to th

Strany 48

1100 Series Capillary LC System Manual 131Parts and Materials 5Tabl e 75 Agilent 1100 to 3396 integratorsConnector03396-60560Pin3392/3PinAgilent 1100S

Strany 49

132 1100 Series Capillary LC System Manual5 Parts and MaterialsAuxiliary CableOne end of this cable provides a modular plug to be connected to the Agi

Strany 50 - Static Mixer and Filter

1100 Series Capillary LC System Manual 133Parts and Materials 5External Contact CableOne end of this cable provides a 15-pin plug to be connected to A

Strany 51

134 1100 Series Capillary LC System Manual5 Parts and MaterialsRS-232 Cable KitThis kit contains a 9-pin female to 9-pin female Null Modem (printer) c

Strany 52

135Agilent 1100 Series Capillary LC SystemSystem ManualAgilent Technologies6OptionsExtended Flow Range Kit (G1376-69707) 1360.1 - 2.5 ml/min Flow Capi

Strany 53 - How the Function Works

136 1100 Series Capillary LC System Manual6OptionsExtended Flow Range Kit (G1376-69707) The extended flow range kit described in Table 80 lets you ada

Strany 54

1100 Series Capillary LC System Manual 137Options 6Figure 39 Capillary pump flow diagramPump head BColumnInjection valveMixerSSVEMPVFlow sensorNeedleA

Strany 55 - Capillaries and Fittings

138 1100 Series Capillary LC System Manual6OptionsInstalling the Extended Flow Range Kit1 Using the 4 mm / 1/4 - 5/16 inch open wrenches disconnect th

Strany 56 - Capillary Flow Diagram

1100 Series Capillary LC System Manual 139Options 60.1 - 2.5 ml/min Flow Capillary Kit (5065-4495)It is possible to use the capillary pump with a flow

Strany 57 - Capillaries and Fittings 3

1100 Series Capillary LC System Manual 5Installing your Capillary LC System 11100Tabl e 2 Module Specific SpecificationsAgilent 1100 Module Part Numbe

Strany 58

140 1100 Series Capillary LC System Manual6OptionsInstalling the 0.1 - 2.5 ml/min flow capillary kit1 Switch off the pump module.2 Disconnect the capi

Strany 59

1100 Series Capillary LC System Manual 141Options 612 Replace the loop capillary with the capillary G1329-87302 if you have a micro autosampler (G1389

Strany 60

142 1100 Series Capillary LC System Manual6Options..Tabl e 82 Pressure drop at 2.5 ml/min for different concentrations (no column)% of organic phase P

Strany 61 - * 1.4 7.6 G1375-87313

1100 Series Capillary LC System Manual 143Options 6Micro Column Switching Valve G1388A#055The micro column switching valve allows to work with 2 colum

Strany 62 - Fittings and Ferrules

144 1100 Series Capillary LC System Manual6OptionsThe micro column switching valve allows also to work with a column back-flushing. The sample is inje

Strany 63

1100 Series Capillary LC System Manual 145Options 6Parts Identification for Micro Column Switching ValveTabl e 84 Micro column switching valveItem Des

Strany 64

146 1100 Series Capillary LC System Manual6OptionsReplacing Rotor Seal of Micro Column Switching Valve15 Remove the stator head and the rotor seal.16

Strany 65 - Basic System Troubleshooting

1100 Series Capillary LC System Manual 147Options 6Removing the Micro Column Switching ValveWhen required If valve failed or bottom foam part has to b

Strany 66 - Symptoms:

148 1100 Series Capillary LC System Manual6Options4 Lift the Z-panel together with the top plastic panel half-way out of the guide.5 Locate the ambien

Strany 67

1100 Series Capillary LC System Manual 149Options 68 Remove the Valve from its location. For the installation refer to “Installing the Micro Column Sw

Strany 68

6 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemSystem Installation ProcessDamaged PackagingIf the delivery packaging sho

Strany 69

150 1100 Series Capillary LC System Manual6OptionsInstalling the Micro Column Switching ValveWhen required For first time installation or after it was

Strany 70

1100 Series Capillary LC System Manual 151Options 63 Carefully insert the top plastic panel together with the Z-panel into the guide and press it half

Strany 71 - Poor peak shape

152 1100 Series Capillary LC System Manual6Options7 Fix the Z-panel with the two screws. 8 Reconnect the grounding connection of the valve at the Z-pa

Strany 72

1100 Series Capillary LC System Manual 153Options 6500 nl Flow Cell Kit G1315-68714This section describes the 500 nl flow cell for Agilent 1100 Series

Strany 73 - Wandering Detector Baseline

154 1100 Series Capillary LC System Manual6OptionsSpecial Information for MaintenanceThe supplied parts with the flow cell allow different fittings an

Strany 74

1100 Series Capillary LC System Manual 155Options 6The cell fittings are factory installed and tested for leakage. These connections should not be use

Strany 75 - Parts and Materials

156 1100 Series Capillary LC System Manual6OptionsInstallation of the Flow CellThe flow cell is supplied with blank capillaries at the instrument side

Strany 76 - Micro Vacuum Degasser

1100 Series Capillary LC System Manual 157Options 6Step 3 and 4 have to be done for each of the two flow cell capillaries, if this connection type is

Strany 77

158 1100 Series Capillary LC System Manual6Options6 The figure below shows the sealing principle within the union “top seal”, hand tightened before to

Strany 78

1100 Series Capillary LC System Manual 159Options 69 Insert the PEEK capillaries from the flow cell body together with the SST fitting, ferrule and co

Strany 79 - Capillary Pump

1100 Series Capillary LC System Manual 7Installing your Capillary LC System 1Installing a Capillary LC System with a Non-Thermostatted SamplerThese in

Strany 80

160 1100 Series Capillary LC System Manual6OptionsConnecting Small I.D. CapillariesColumns from e.g. LC Packings have capillary connections which are

Strany 81

1100 Series Capillary LC System Manual 161Options 6Replacing or Cleaning PartsCAUTIONThe quartz block can be cleaned with alcohol. DO NOT touch the in

Strany 82 - Capillary Pump Hydraulic Path

162 1100 Series Capillary LC System Manual6Options5 The quartz body and the cell seal assembly can be separated for cleaning purpose.6 This figure sho

Strany 83

1100 Series Capillary LC System Manual 163Options 69 Insert the flow cell capillaries and tighten them fingertight.Use of the wrench and torque adapte

Strany 84 - Pump-Head Assembly

164 1100 Series Capillary LC System Manual6Options

Strany 85 - Figure 9 Pump head assembly

165Agilent 1100 Series Capillary LC SystemSystem ManualAgilent Technologies7Performance SpecificationsPerformance Specifications Agilent 1100 Series C

Strany 86 - Capillary pump cover parts

166 1100 Series Capillary LC System Manual7 Performance SpecificationsPerformance Specifications Agilent 1100 Series Capillary PumpTabl e 86 Performan

Strany 87 - Micro Well-plate Sampler

1100 Series Capillary LC System Manual 167Performance Specifications 7Delay volume Typically 3 µl from the electronic flow control to the pump outlet

Strany 88

168 1100 Series Capillary LC System Manual7 Performance SpecificationsPerformance Specifications Agilent 1100 Series Micro Vacuum DegasserTabl e 88 Pe

Strany 89

1100 Series Capillary LC System Manual 169Performance Specifications 7Performance Specifications Agilent 1100 Series Thermostatted Micro AutosamplerTa

Strany 90

8 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInstall the Diode Array Detector (DAD) (G1315B)Ensure the line power swit

Strany 91

170 1100 Series Capillary LC System Manual7 Performance SpecificationsPerformance specification Agilent 1100 Series Micro Well-plate SamplerTabl e 90

Strany 92

1100 Series Capillary LC System Manual 171Performance Specifications 7Performance Specifications Agilent 1100 Thermostatted Column Compartment.All spe

Strany 93

172 1100 Series Capillary LC System Manual7 Performance SpecificationsPerformance Specifications Agilent 1100 Series DADReference conditions for data

Strany 94

1100 Series Capillary LC System Manual 173Performance Specifications 7For specification on the 500 nl flow cell refer to Table 85 on page 153.Maximum

Strany 95

174 1100 Series Capillary LC System Manual7 Performance Specifications

Strany 96

175Agilent 1100 Series Capillary LC SystemSystem ManualAgilent TechnologiesASafety InformationThe following general safety precautions must be observe

Strany 97

176 1100 Series Capillary LC System ManualA Safety InformationGeneralThis is a Safety Class I instrument (provided with terminal for protective earthi

Strany 98 - Thermostat for 1100 Samplers

1100 Series Capillary LC System Manual 177Safety Information ACapacitors inside the instrument may still be charged, even though the instrument has be

Strany 99

178 1100 Series Capillary LC System ManualA Safety InformationLithium Batteries InformationDanish Information:.WARNINGDanger of explosion if battery i

Strany 100 - 5 Parts and Materials

1100 Series Capillary LC System Manual 179Safety Information ARadio InterferenceNever use cables other than the ones supplied by Agilent Technologies

Strany 101 - Parts and Materials 5

1100 Series Capillary LC System Manual 9Installing your Capillary LC System 1Install the Thermostatted Column Compartment (TCC) (G1316A)1 Ensure the l

Strany 102

180 1100 Series Capillary LC System ManualA Safety Information• High concentrations of inorganic acids like nitric acid, sulfuric acid especially at h

Strany 103

1100 Series Capillary LC System Manual 181IndexNumerics500 nl flow cell, 153Aaccuracy of temperaturecolumn compartment, 171accuracy of wavelength, 172

Strany 104 - Vial Trays

182 1100 Series Capillary LC System ManualIndexMmaximum flow rate, 168metering seal, 81, 91micro column switching valve (optional)description, 143inst

Strany 105

1100 Series Capillary LC System Manual 183Indexsystem pressurehigh, 57low, 56unstable, 59system troubleshooting, 55TTCCinstalling, 9temperaturerange,

Strany 106

184 1100 Series Capillary LC System ManualIndex

Strany 108

' %%(&'' %%(&'G1388-90001s1In This BookThis manual contains technical reference information about the Agilent

Strany 109

ii 1100 Series Capillary LC System ManualNotices© Agilent Technologies, Inc. 2002No part of this manual may be reproduced in any form or by any means

Strany 110

10 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInstall the Micro Well-plate Sampler (G1377A)1 Ensure the line power swi

Strany 111 - Diode Array Detector

1100 Series Capillary LC System Manual 11Installing your Capillary LC System 1Install the Capillary Pump (G1376A)1 Ensure the line power switch at the

Strany 112

12 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInstall the Micro Vacuum Degasser (G1379A)1 Ensure the line power switch

Strany 113 - DAD - Optical Unit Assembly

1100 Series Capillary LC System Manual 13Installing your Capillary LC System 1Install the Solvent Cabinet1 Place the solvent cabinet on top of the deg

Strany 114 - Figure 30 Optical Unit Parts

14 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInstalling a Capillary LC System with a Thermostatted Micro SamplerThese

Strany 115 - 500 nl Flow Cell

1100 Series Capillary LC System Manual 15Installing your Capillary LC System 1Install the Thermostat for 1100 Samplers (G1330B)1 Place the thermostat

Strany 116

16 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInstall the Micro Sampler (G1387A Micro Autosampler (ALS), or G1378A Mic

Strany 117 - Fan Assembly Parts

1100 Series Capillary LC System Manual 17Installing your Capillary LC System 1Install the Thermostatted Column Compartment (TCC) (G1316A)1 Ensure that

Strany 118 - Holmium Oxide Filter

18 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInstall the Diode Array Detector (DAD) (G1315B)1 Ensure the line power s

Strany 119

1100 Series Capillary LC System Manual 19Installing your Capillary LC System 1Install the Capillary Pump (G1376A)1 Ensure the line power switch at the

Strany 120 - Common Parts

1100 Series Capillary LC System Manual iiiIn This Manual…This manu

Strany 121 - Rear panel

20 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInstall the Micro Vacuum Degasser (G1379A)1 Ensure the line power switch

Strany 122 - Power and Status Light Pipes

1100 Series Capillary LC System Manual 21Installing your Capillary LC System 1Install the Solvent Cabinet1 Place the solvent cabinet on top of the deg

Strany 123 - Leak Parts

22 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemGet the System Ready for the First InjectionWhen you are using the syste

Strany 124 - Sheet metal kit

1100 Series Capillary LC System Manual 23Installing your Capillary LC System 1Manually Priming the Solvent Channels.1 The degasser accessory kit conta

Strany 125 - Micro Degasser Accessory Kit

24 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemPurging the Pump1 Make sure that the 1/8 inch plastic waste tube is tigh

Strany 126 - Capillary Pump Accessory Kit

1100 Series Capillary LC System Manual 25Installing your Capillary LC System 1Conditioning the System Under Method ConditionsIf you wish to condition

Strany 127

26 1100 Series Capillary LC System Manual1 Installing your Capillary LC SystemInject the Check-out SampleThe purpose of the instrument check is to dem

Strany 128

1100 Series Capillary LC System Manual 27Installing your Capillary LC System 1Procedure1 Make a single injection of the isocratic test standard under

Strany 129 - G1316-68725

28 1100 Series Capillary LC System Manual1 Installing your Capillary LC System

Strany 130 - DAD Accessory Kit

29Agilent 1100 Series Capillary LC SystemSystem ManualAgilent Technologies2Optimizing PerformanceHints for Successful Use of the Capillary Pump 30Solv

Strany 131 - Tabl e 61 Cables overview

iv 1100 Series Capillary LC System Manual

Strany 132

30 1100 Series Capillary LC System Manual2 Optimizing PerformanceHints for Successful Use of the Capillary PumpPump issues• Flush the pump extensively

Strany 133 - Analog Cables

1100 Series Capillary LC System Manual 31Optimizing Performance 2• To achieve the best flow stability, especially in the micro mode, %Ripple must be w

Strany 134 - Remote Cables

32 1100 Series Capillary LC System Manual2 Optimizing PerformanceSampler issues• For fast gradient use valve to bypass function after the sample is tr

Strany 135

1100 Series Capillary LC System Manual 33Optimizing Performance 2Solvent InformationAlways filter solvents through 0.4 µm filters, small particles can

Strany 136

34 1100 Series Capillary LC System Manual2 Optimizing PerformancePrevent Blocking of Solvent Inlet FiltersContaminated solvents or algae growth in the

Strany 137

1100 Series Capillary LC System Manual 35Optimizing Performance 2Cleaning the Solvent Filters• Remove the blocked solvent filter from the bottle-head

Strany 138

36 1100 Series Capillary LC System Manual2 Optimizing PerformanceHints for the Micro Vacuum DegasserIf you are using the vacuum degasser for the first

Strany 139

1100 Series Capillary LC System Manual 37Optimizing Performance 2When to use Alternative SealsThe standard seals for the capillary pump can be used fo

Strany 140 - BCD Cables

38 1100 Series Capillary LC System Manual2 Optimizing PerformanceHow to Choose the Primary FlowPrimary Flow is a parameter which exists only when the

Strany 141

1100 Series Capillary LC System Manual 39Optimizing Performance 2Fast Gradients range (800-1300 µl/min)In this range, the pump gradient delay time is

Strany 142 - CAN Cable

1100 Series Capillary LC System Manual vContents1 Installing your Capillary LC SystemSite Requirements 2Physical Specifications 4System Installation P

Strany 143 - External Contact Cable

40 1100 Series Capillary LC System Manual2 Optimizing PerformanceStatic Mixer and FilterThe capillary pump is equipped with a static mixer and an inli

Strany 144 - LAN Cables

1100 Series Capillary LC System Manual 41Optimizing Performance 2How to Optimize the Compressibility Compensation SettingThe compressibility compensat

Strany 145

42 1100 Series Capillary LC System Manual2 Optimizing Performance5 Starting with a compressibility setting of 10 × 10-6/bar increase the value in step

Strany 146

1100 Series Capillary LC System Manual 43Optimizing Performance 2The Fast Composition Change/Reconditioning FunctionPurposeThe capillary pump and the

Strany 147 - Options 6

44 1100 Series Capillary LC System Manual2 Optimizing Performance2 When the Fast System Flush time has elapsed, the micro well-plate sampler needle is

Strany 148

45Agilent 1100 Series Capillary LC SystemSystem ManualAgilent Technologies3Capillaries and FittingsCapillary Flow Diagram 46Connecting capillaries for

Strany 149

46 1100 Series Capillary LC System Manual3 Capillaries and FittingsCapillary Flow DiagramThe flow diagram in Figure 2 gives an overview of the capilla

Strany 150

1100 Series Capillary LC System Manual 47Capillaries and Fittings 3Connecting capillaries for the capillary LC system† SST: stainless steel* * PFS: Pe

Strany 151

48 1100 Series Capillary LC System Manual3 Capillaries and Fittings* PFS: Peek coated fused silica.*PFS: Peek coated fused silicaTabl e 8 Specific cap

Strany 152 - 6Options

1100 Series Capillary LC System Manual 49Capillaries and Fittings 3† SST: Stainless steel* * PFS: Peek coated fused silicaDescriptionsto Table 1 01 T

Strany 153

vi 1100 Series Capillary LC System Manualcontents2 Optimizing PerformanceHints for Successful Use of the Capillary Pump 30Pump issues 30Fused Silica C

Strany 154

50 1100 Series Capillary LC System Manual3 Capillaries and FittingsTabl e 11 Specific capillaries for use with a micro CSV and a 20 µl flow sensorFrom

Strany 155

1100 Series Capillary LC System Manual 51Capillaries and Fittings 3Figure 3 Micro column switching valve connections1234To det e c t o rFrom injection

Strany 156 - 9/64 inch hex key

52 1100 Series Capillary LC System Manual3 Capillaries and FittingsFittings and FerrulesTabl e 14 Fittings and ferrulesFitting Typ eName Description

Strany 157 - • Disconnect capillaries

1100 Series Capillary LC System Manual 53Capillaries and Fittings 3Instructions to connect a capillary.With Swagelock fitting (type A)• Slide the nut,

Strany 158

54 1100 Series Capillary LC System Manual3 Capillaries and FittingsHints for Successful use of Capillaries and Fittings• Never overtighten a fitting.•

Strany 159

55Agilent 1100 Series Capillary LC SystemSystem ManualAgilent Technologies4Basic System TroubleshootingSystem Pressure Abnormally Low 56System Pressur

Strany 160

56 1100 Series Capillary LC System Manual4 Basic System TroubleshootingSystem Pressure Abnormally LowSymptoms: The current system pressure is signific

Strany 161

1100 Series Capillary LC System Manual 57Basic System Troubleshooting 4System Pressure Abnormally HighSymptoms: The current system pressure is signifi

Strany 162

58 1100 Series Capillary LC System Manual4 Basic System TroubleshootingEMPV failed to initialize (micro mode only)Symptoms: An attempt to pump in the

Strany 163 - Performance Specification

1100 Series Capillary LC System Manual 59Basic System Troubleshooting 4Unstable column flow and/or system pressureSymptoms: In the micro mode, the pum

Strany 164

contents1100 Series Capillary LC System Manual vii4 Basic System TroubleshootingSystem Pressure Abnormally Low 56System Pressure Abnormally High 57EMP

Strany 165

60 1100 Series Capillary LC System Manual4 Basic System TroubleshootingDirty solvent inlet filters. Solvent intake is being restricted. %Ripple might

Strany 166 - Installation of the Flow Cell

1100 Series Capillary LC System Manual 61Basic System Troubleshooting 4Poor peak shapeSymptoms: The peak shape has taken on a fronting or tailing char

Strany 167 - ~ 0.3 mm clearance

62 1100 Series Capillary LC System Manual4 Basic System TroubleshootingFailure to produce peaks, or abnormally small peaks, after injectionSymptoms: T

Strany 168

1100 Series Capillary LC System Manual 63Basic System Troubleshooting 4Wandering Detector BaselineCritical Decision Determine if the problem is in the

Strany 169

64 1100 Series Capillary LC System Manual4 Basic System TroubleshootingUser interface displays error messages for specific modulesUnstable flow and/or

Strany 170

65Agilent 1100 Series Capillary LC SystemSystem ManualAgilent Technologies5Parts and MaterialsMicro Vacuum Degasser 66,Capillary Pump 69,Micro Well-pl

Strany 171 - Replacing or Cleaning Parts

66 1100 Series Capillary LC System Manual5 Parts and MaterialsMicro Vacuum Degasser Table 16 gives an overview over the main assemblies:Tabl e 16 Micr

Strany 172

1100 Series Capillary LC System Manual 67Parts and Materials 5Figure 4 Micro vacuum degasser main assemblies991112345678

Strany 173

68 1100 Series Capillary LC System Manual5 Parts and MaterialsMicro Vacuum Degasser Cover PartsFigure 5 Micro vacuum degasser cover partsTabl e 17 Mic

Strany 174

1100 Series Capillary LC System Manual 69Parts and Materials 5Capillary Pump Table 18 gives an overview over the main assemblies of the capillary pump

Strany 175 - Performance Specifications

viii 1100 Series Capillary LC System ManualcontentsVial Trays 94Thermostatted Column Compartment 95Micro Column Switching Valve 97Thermostatted Column

Strany 176 - 7 Performance Specifications

70 1100 Series Capillary LC System Manual5 Parts and MaterialsFigure 6 Capillary pump main assembly7912135264108111314

Strany 177 - Performance Specifications 7

1100 Series Capillary LC System Manual 71Parts and Materials 5Solvent Cabinet and Bottle Head AssemblyFigure 7 Solvent cabinet and bottle head assembl

Strany 178

72 1100 Series Capillary LC System Manual5 Parts and MaterialsCapillary Pump Hydraulic PathTabl e 20 Capillary pump hydraulic pathItem Description Par

Strany 179 - Autosampler

1100 Series Capillary LC System Manual 73Parts and Materials 5Figure 8 Capillary pump hydraulic path8109111234567

Strany 180

74 1100 Series Capillary LC System Manual5 Parts and MaterialsPump-Head AssemblyTabl e 21 Pump-head assemblyItem Description Part NumberPump head asse

Strany 181 - Compartment

1100 Series Capillary LC System Manual 75Parts and Materials 5Figure 9 Pump head assembly1235671194810

Strany 182

76 1100 Series Capillary LC System Manual5 Parts and MaterialsCapillary pump cover partsTable 22 gives an overview over the cover parts of the capilla

Strany 183

1100 Series Capillary LC System Manual 77Parts and Materials 5Micro Well-plate SamplerFigure 11 Micro well-plate sampler main assemblies67532913112810

Strany 184

78 1100 Series Capillary LC System Manual5 Parts and MaterialsTabl e 23 Micro well-plate sampler main assembliesItem Description Part Number1 Ribbon C

Strany 185 - Safety Information

1100 Series Capillary LC System Manual 79Parts and Materials 5Sampling Unit for the Micro Well-plate SamplerFigure 12 Sampling unit for the micro well

Strany 186 - Operation

contents1100 Series Capillary LC System Manual ixCAN Cable 132External Contact Cable 133RS-232 Cable Kit 134LAN Cables 1346OptionsExtended Flow Range

Strany 187 - Safety Symbols

80 1100 Series Capillary LC System Manual5 Parts and MaterialsTabl e 24 Sampling unit for the micro well-plate samplerItem Description Part NumberSamp

Strany 188 - Danish Information:

1100 Series Capillary LC System Manual 81Parts and Materials 5Micro Analytical Head AssemblyTabl e 25 Micro analytical head assemblyItem Description P

Strany 189 - Solvent Information

82 1100 Series Capillary LC System Manual5 Parts and MaterialsMicro Injection Valve AssemblyNote : Tabl e 26 Micro injection valve assemblyItem Descri

Strany 190

1100 Series Capillary LC System Manual 83Parts and Materials 5Micro Well-plate Sampler - Vial TraysTabl e 27 Micro well-plate sampler vial trays and t

Strany 191

84 1100 Series Capillary LC System Manual5 Parts and MaterialsTabl e 28 Recommended plates and closing matDescription Rows Columns Plate height Volum

Strany 192

1100 Series Capillary LC System Manual 85Parts and Materials 5Micro Well-Plate Sampler Cover PartsTabl e 29 Micro well-plate sampler cover partsItem D

Strany 193

86 1100 Series Capillary LC System Manual5 Parts and MaterialsThermostatted Micro AutosamplerTable 30 offers an overview over the main assemblies of t

Strany 194

1100 Series Capillary LC System Manual 87Parts and Materials 5Figure 17 Thermostatted micro autosampler main assemblies765321948101112

Strany 195

88 1100 Series Capillary LC System Manual5 Parts and MaterialsThermostat for 1100 Samplers Figure 18 ThermostatTabl e 31 Thermostat for micro autosamp

Strany 196 - ' %%(&'

1100 Series Capillary LC System Manual 89Parts and Materials 5Sampling Unit for the Micro AutosamplerFigure 19 offers an overview over the main assemb

Komentáře k této Příručce

Žádné komentáře