Agilent Technologies 6612B Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Multimetry Agilent Technologies 6612B. Agilent Technologies 6612B User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Interface

Agilent SS420x Interface User’s Guide

Strany 2 - Notices

Analog Interface Connector A twelve-pin snap lock modular connector (AKZ-950-STL12W) provides the analog interface connection. The connector is

Strany 3 - Contents

Relay Interface Connector Two eight-pin snap lock modular connectors (AKZ-950-STL8W) provide the relay interface connection. The connectors are

Strany 4

4 RLY6B 5 RLY7A 6 RLY7B 7 RLY8A 8 RLY8B Trigger/Start Interface Connector An eight-pin snap lock modular connector (AKZ-950-STL8W) provides the

Strany 5 - 1 Using This Guide

7 START4 8 GND4 Serial RS-232 Interface Connector There is one external RS-232 Serial interface provided by the SS420x via a DB-9S: RS-232 (J5)

Strany 6 - 2 Hardware Overview

POWER (J6) 1 9 Volts 2 Ground BCD Inputs Connector There is one external BCD input interface. This interface is currently not supported. Tran

Strany 7 - SS420x User’s Guide 7

6 Configuration for EZChrom Elite In order to use an SS420x for data acquisition, you must complete the configuration steps shown below. First,

Strany 8

Baud Rate The communication baud rate is displayed here. To change the baud rate, click the Advanced button. Base Frequency Select the ba

Strany 9 - 5 SS420x Installation

If selected incorrectly, you may see line frequency noise on your chromatogram. For best performance, select a base frequency close to the maximum s

Strany 10 - 10 SS420x User’s Guide

the instrument and its detectors. To start the configuration of an instrument, do a right mouse click on the instrument from the Main menu, and selec

Strany 11

SS420x Channel Configuration For the detector selected, set the correct Serial Port, and Channel to be used. These should match the way your det

Strany 12 - Caution!

Notices Copyright © Scientific Software, Inc 1997-2005 © Agilent Technologies, Inc. 2005-2006. No part of this manual may be reproduced in any form or

Strany 13 - SS420x User’s Guide 13

To start the event configuration, double click on the Event Configuration icon in the Configured modules area. The following events can be configure

Strany 14

SS420x Trigger Configuration Select Trigger in the Name column. Select SS420x for Source. Then click Setup. The following dialog will appear.

Strany 15 - SS420x Configuration

Select the Serial Port and the relay to be used for the Ready. These should match the physical connections on the SS420x interface for this ready lin

Strany 16 - 16 SS420x User’s Guide

7 Configuration for OpenLAB If you will be using an SS420x attached to the Agilent Instrument Controller (required for analog acquisition), it w

Strany 17

Baud Rate Select the communication baud rate you wish to use. To send the updated baud rate to the SS420x, click the Set Baud Rate button. Bas

Strany 18 - 18 SS420x User’s Guide

Sampling frequencies available in the Acquisition Setup portion of the method will reflect the Base Frequency selected. Range For each channel

Strany 19

Instruments using SS420x for acquisition may be configured as any available instrument type. If instrument type other than Generic is selected, the d

Strany 20 - 20 SS420x User’s Guide

When you have finished this dialog, click OK. SS420x Event Configuration If you plan to use event control from the SS420x, you must configure i

Strany 21

The following events can be configured for control by the SS420x. If an event type is not configured, it will not be available for programming in th

Strany 22 - 22 SS420x User’s Guide

must have its own trigger configured. When completed, click OK. SS420x Ready Configuration To configure a Ready signal, select Ready for Name, s

Strany 23

Contents 1 Using This Guide...5 Introduction ...

Strany 24 - 24 SS420x User’s Guide

Select the Serial Port and the Relay to be used for the valve/event control. Then select the Idle State (State of the relay before the run) to be se

Strany 25

SS420x Channel Configuration... 19 SS420x Event Configuration .

Strany 26 - 26 SS420x User’s Guide

1 Using This Guide Introduction The SS420x is an intelligent instrument interface box designed to collect analog data, and input and output

Strany 27

then you must type the actual name of the server instead of the italicized term. Monospace Programming code samples and display text. ALL CAPITALS Th

Strany 28 - 28 SS420x User’s Guide

ADC data obtained from the SS420 circuitry and passes that data back to the PC via the serial interface. SS420 Circuitry – The SS420x circuitry provi

Strany 29

3 Specifications Dynamic Range: >1,000,000 : 1 Input Signal Range: -5 to +11 Volt Maximum Input Voltage Without Damage: Continuous: +30V (power

Strany 30 - 30 SS420x User’s Guide

4 Data Collection The SS420x archives the 24-bit ADC data into four separate long-term buffers for each of its analog channels. Each channel ca

Komentáře k této Příručce

Žádné komentáře