Agilent Technologies 8487D Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Multimetry Agilent Technologies 8487D. Agilent N1913A and N1914A EPM Series Power Meters Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 27
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Agilent N1913A and N1914A
EPM Series Power Meters
E-Series and 8480 Series Power Sensors
Consistent Results and Greater Capability
Data Sheet
Essential specifications
Frequency range: 9 kHz to
110GHz
Power range: –70 dBm to
+44dBm (100 pW to 25 W,
depending on the attached
power sensor)
Measurement speed: Up to
400readings/sec with
E-Series sensors
Absolute accuracy: ±0.02 dB
logarithmic, ±0.5% linear
Relative accuracy: ±0.04 dB
logarithmic, ±1% linear
As signals become more complex, it
becomes more difficult to make fast,
accurate power measurements. For
years, you’ve depended on Agilent’s
EPM Series power meters. Today,
the Agilent N1913A and N1914A
EPM power meters are versatile,
user-friendly replacements for the
E4418B/19B EPM Series. Best of
all, you get these extras for about
the same price as the EPM Series.
Get consistent results and greater
capability—with the new EPM power
meters.
Do more with new-generation EPM power meters
Get up to four channels
1
to speed and simplify RF average power measurements
Measure faster with improved measurement speed of 400 readings/sec with
the Agilent E-Series sensors
View test results more easily with the industry’s first color LCD readout in an
average power meter
Go beyond GPIB with USB and LAN/LXI-C interfaces
Automate frequency/power sweep measurements with the optional external
trigger in/out feature
Confirm battery power with a single-button push
2
—and get extra operating
time with the optional spare battery
Easily replace existing 436A. 437B and 438A meters with optional 43x code
compatibility
3
Enhance manufacturing test by connecting a large external monitor with the
unique VGA output option
1. Additional two optional USB channels available (see Ordering Information, page10)
2. Only applicable for models with battery option (see Ordering Information, page 10)
3. N1913A is backward compatible with the 436A and 437B, while N1914A is compatible with 438A
Zobrazit stránku 0
1 2 3 4 5 6 ... 26 27

Shrnutí obsahu

Strany 1 - EPM Series Power Meters

Agilent N1913A and N1914AEPM Series Power Meters E-Series and 8480 Series Power SensorsConsistent Results and Greater CapabilityData SheetEssential sp

Strany 2 - Take a Closer Look

10N1913A/14A EPM Series Power Meters Ordering InformationPower metersN1913ASingle-channel average power meterN1914ADual-channel average power meterSta

Strany 3 - Average Power Measurements

11E-Series Power Sensor SpecificationsThe E-Series of power sensors have their calibration factors stored in EEPROM and operate over a wide dynamic ra

Strany 4 - Accuracy

12E-Series CW Power Sensor Specifications (continued)Calibration factor (CF) and reflection coefficient (Rho)Calibration factor and reflection coeffic

Strany 5

13E-Series CW Power Sensor Specifications (continued)Power linearityTable 6. E4410 Series power linearity specification Power Temperature (25 °C ±5 °C

Strany 6

14E-Series E9300 Average Power Sensor SpecificationsThe E-Series E9300 wide dynamic range, average power sensors are designed for use with the EPM fam

Strany 7

15E-Series E9300 Average Power Sensor Specifications (continued)1.21.181.161.141.121.11.081.061.041.021SWRFrequency GHz0.01 2.00 4.00 6.00 8.00 10.00

Strany 8

16E-Series E9300 Average Power Sensor Specifications (continued)Power linearity*Table 9. E9300 Series power linearity (after zero and cal at ambient e

Strany 9

17E-Series E9300 Average Power Sensor Specifications (continued)Effects of change in temperature on linearityNote: If the temperature changes after ca

Strany 10

18E-Series E9300 Average Power Sensor Specifications (continued)Switch point dataThe E9300 power sensors have two paths as shown in Table 7. The power

Strany 11 - (continued)

19E-Series E9300 Average Power Sensor Specifications (continued)Calibration factor (CF) and reflection coefficient (Rho)Calibration factor and reflect

Strany 12

2Take a Closer Look N1914A front panelN1914A back panelIndustry’s first high-resolution color LCD in an average power meterDisplay keys select the dis

Strany 13

20848xD Series Diode and 8483A Thermocouple Power Sensor SpecificationsCalibration factor uncertaintiesThese thermocouple and diode power sensors prov

Strany 14

21848xD Series Diode and 8483A Thermocouple Power Sensor Specifications (continued)Maximum SWR and power linearityTable 14. 8480 Series maximum SWR an

Strany 15

22N8480 Series Thermocouple Power Sensor SpecificationsThe N8480 Series power sensors (excluding Option CFT) measure power levels from –35 dBm to +44

Strany 16

23N8480 Series Thermocouple Power Sensor Specifications (continued)Maximum SWR and power linearity for standard N8480 Series power sensorsTable 16. N8

Strany 17

24N8480 Series Thermocouple Power Sensor Specifications (continued)Switch point dataSwitching point is applicable for standard N8480 Series power sens

Strany 18

25U2000 Series USB Power Sensor SpecificationsFrequency and power rangesTable 17. U2000 Series USB sensors frequency and power rangesModel Frequency r

Strany 19

26U2000 Series USB Power Sensor Specifications (continued)Maximum SWRTable 19. U2000 Series USB sensors maximum SWRModel Frequency rangeMaximum SWR(25

Strany 20

www.agilent.comwww.agilent.com/find/epmAgilent Email Updateswww.agilent.com/find/emailupdatesGet the latest information on the products and applicatio

Strany 21

3N1913A/14A Series Power Meter: Applications and Compatible Sensors for Average Power MeasurementsSignal characteristics > CW ModulatedCWPulse/aver

Strany 22

4N1913A/14A EPM Series Power Meters Performance CharacteristicsSpecifications describe the instrument’s warranted performance and apply after a 30 min

Strany 23

5N1913A/14A EPM Series Power Meters Performance Characteristics (continued)1 mW power referencePower output 1.00 mW (0.0 dBm). Factory set to ±0.4 % t

Strany 24

6N1913A/14A EPM Series Power Meters Performance Characteristics (continued)Table 3. Settling timeNumber of averages 12481632641282565121024Settling ti

Strany 25 - USB host port (options)

7+40 dBm+32 dBm+26 dBm+20 dBm+10 dBm0 dBm–10 dBm–20 dBm+20 dBm+12 dBm+6 dBm0 dBm–10 dBm–20 dBm–30 dBm–40 dBmTypicalsettlingtimesx2 speedNormal speed40

Strany 26

8N1913A/14A EPM Series Power Meters Performance Characteristics (continued)Power meter functionsAccessed by key entry Either hard keys, or soft key me

Strany 27 - DEKRA Certified

9N1913A/14A EPM Series Power Meters Performance Characteristics (continued)Line powerInput voltage range 90 to 264 VAC, automatic selectionInput frequ

Komentáře k této Příručce

Žádné komentáře