Agilent Technologies U3606B Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Multimetry Agilent Technologies U3606B. Agilent Technologies U3606B User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 205
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Multimeter

Agilent TechnologiesAgilent U3606B Multimeter|DC Power SupplyUser’s GuideU3606-90054_UG_EN.book Page I Friday, July 11, 2014 5:12 PM

Strany 2

X U3606B User’s GuideMeasuring Frequency/Pulse Width/Duty Cycle (Current Path) 56Selecting a Range 59Setting the Resolution 61Math Oper

Strany 3 - Safety Symbols

3 DC Power Supply Operation Constant Current Operation84 U3606B User’s GuideSelect the constant current functionAdjust the constant current value5LOA

Strany 4 - Safety Considerations

DC Power Supply Operation 3 Constant Current OperationU3606B User’s Guide 85Enable the output8NOTE• The output current is limited by the range selecte

Strany 5 - Environmental Conditions

3 DC Power Supply Operation Protection Functions86 U3606B User’s GuideProtection FunctionsOver-voltage protection (OVP)In constant current mode, the

Strany 6 - Regulatory Markings

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 87Select the OVP functionAdjust the OVP value and save the changes43The OVP annunc

Strany 7

3 DC Power Supply Operation Protection Functions88 U3606B User’s GuideChecking the OVP operationTo check OVP operation, raise the regulated output cu

Strany 8

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 89This will disable the U3606B output, cause the CC annunciator to flash, and the

Strany 9 - Table of Contents

3 DC Power Supply Operation Protection Functions90 U3606B User’s GuideOver-current protection (OCP)In constant voltage mode, the U3606B regulates the

Strany 10 - 3 DC Power Supply Operation

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 91Select the OCP functionAdjust the OCP value and save the changes43The OVP annunc

Strany 11 - 4 System-Related Operation

3 DC Power Supply Operation Protection Functions92 U3606B User’s GuideChecking the OCP operationTo check OCP operation, raise the regulated output cu

Strany 12 - 6 List of Error Messages

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 93This will disable the U3606B output, cause the CC annunciator to flash, and the

Strany 13 - List of Figures

U3606B User’s Guide XI4 System-Related OperationUsing the Utility Menu 124Utility Menu Summary 126Utility Menu Items 129Reading error m

Strany 14 - XIV U3606B User’s Guide

3 DC Power Supply Operation Protection Functions94 U3606B User’s GuideOver-voltage limit (OV)The over- voltage limit prevents the output voltage pres

Strany 15 - List of Tables

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 95Select the OV functionAdjust the OV value and save the changes43The OV annunciat

Strany 16 - XVI U3606B User’s Guide

3 DC Power Supply Operation Protection Functions96 U3606B User’s GuideNOTE• After adjusting the OV value, you can also press [Limit] again to save th

Strany 17 - Introduction

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 97Over-current limit (OC)The over- current limit prevents the output current flowi

Strany 18 - About This Manual

3 DC Power Supply Operation Protection Functions98 U3606B User’s GuideSelect the OC functionAdjust the OC value and save the changes43The OC annuncia

Strany 19 - Preparing the U3606B

DC Power Supply Operation 3 Protection FunctionsU3606B User’s Guide 99NOTE• After adjusting the OC value, you can also press [Limit] again to save the

Strany 20 - 4 U3606B User’s Guide

3 DC Power Supply Operation Square-Wave Operation100 U3606B User’s GuideSquare-Wave OperationThe square- wave function is a unique function for many

Strany 21

DC Power Supply Operation 3 Square-Wave OperationU3606B User’s Guide 101Select the square wave functionView the amplitude, duty cycle, and pulse width

Strany 22

3 DC Power Supply Operation Square-Wave Operation102 U3606B User’s GuideEnable the output7U3606-90054_UG_EN.book Page 102 Friday, July 11, 2014 5:

Strany 23 - Adjust the carry handle

DC Power Supply Operation 3 Square-Wave OperationU3606B User’s Guide 103Adjust the amplitude, duty cycle, and pulse width valuesAdjust the amplitude v

Strany 24 - Rack mount the instrument

XII U3606B User’s GuideDigital Multimeter Specifications 158Specification assumptions 158DC specifications 159AC specifications 16

Strany 25 - U3606B User’s Guide 9

3 DC Power Supply Operation Square-Wave Operation104 U3606B User’s GuideAdjust the frequency, duty cycle, or pulse width values and save the changesU

Strany 26 - Stack multiple U3606B units

DC Power Supply Operation 3 Square-Wave OperationU3606B User’s Guide 105Table 3 - 5 Square-wave amplitude minimum and maximum valuesRangeSquare wave a

Strany 27 - The U3606B in Brief

3 DC Power Supply Operation Sweep Functions106 U3606B User’s GuideSweep FunctionsThe U3606B is equipped with ramp and scan capability. Use the ramp f

Strany 28 - Overview

DC Power Supply Operation 3 Sweep FunctionsU3606B User’s Guide 107Connect the load1LOAD32U3606-90054_UG_EN.book Page 107 Friday, July 11, 2014 5:12

Strany 29 - Rear panel

3 DC Power Supply Operation Sweep Functions108 U3606B User’s GuideSelect the constant voltage or constant current functionSelect the ramp function an

Strany 30 - 14 U3606B User’s Guide

DC Power Supply Operation 3 Sweep FunctionsU3606B User’s Guide 109Scan signalA typical scan signal length is based on the following parameters:• the a

Strany 31 - Display screen

3 DC Power Supply Operation Sweep Functions110 U3606B User’s GuideThe total dwell time will increase with respect to the number of steps and the scan

Strany 32 - 16 U3606B User’s Guide

DC Power Supply Operation 3 Sweep FunctionsU3606B User’s Guide 111Select the constant voltage or constant current functionSelect the scan function and

Strany 33 - U3606B User’s Guide 17

3 DC Power Supply Operation Sweep Functions112 U3606B User’s GuideNOTE• The scan dwell time also affects the first step at amplitude 0. An initial de

Strany 34

DC Power Supply Operation 3 Selecting a RangeU3606B User’s Guide 113Selecting a RangeYou can allow the U3606B to automatically select the range using

Strany 35 - Using the Shift key

U3606B User’s Guide XIIIList of FiguresFigure 1-1 Single rack mounted U3606B 8Figure 1-2 Two U3606B rack mounted side-by-side 8Figure 1-3 Rac

Strany 36 - 20 U3606B User’s Guide

3 DC Power Supply Operation Enabling the Output114 U3606B User’s GuideEnabling the OutputPress [] to turn the U3606B output on or off.With the outpu

Strany 37 - U3606B User’s Guide 21

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 115Remote SensingRemote sensing is used to maintain regulation at the load and reduce de

Strany 38 - 22 U3606B User’s Guide

3 DC Power Supply Operation Remote Sensing116 U3606B User’s GuideRemote sensing connectionsRemote sensing requires connecting the load leads from the

Strany 39 - U3606B User’s Guide 23

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 117Connecting the load leads to the rear terminal block1 Turn off the power. Remove all

Strany 40 - Input/Output terminals

3 DC Power Supply Operation Remote Sensing118 U3606B User’s Guide4 Loosen the top screws with a slotted screw driver and connect the rear output term

Strany 41 - U3606B User’s Guide 25

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 119Do not loosen the top screws of the rear output terminal block at a tilted angled.CAU

Strany 42 - 26 U3606B User’s Guide

3 DC Power Supply Operation Remote Sensing120 U3606B User’s GuideEnable remote sensingTo configure the U3606B for remote sensing:1 Turn off the U3606

Strany 43 - U3606B User’s Guide 27

DC Power Supply Operation 3 Remote SensingU3606B User’s Guide 121StabilityUsing remote sensing under certain combinations of load lead lengths and lar

Strany 44 - 28 U3606B User’s Guide

3 DC Power Supply Operation Remote Sensing122 U3606B User’s GuideWith remote sensing, any voltage dropped in the load leads must be added to the load

Strany 45 - Operation and Features

123U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies4System-Related OperationUsing the Utility Menu 124Utility Menu Summary 126U

Strany 46 - Measuring Voltage

XIV U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_EN.book Page XIV Friday, July 11, 2014 5:12 PM

Strany 47 - Voltage measurement summary

4 System-Related Operation Using the Utility Menu124 U3606B User’s GuideUsing the Utility MenuThe Utility menu allows you to customize a number of no

Strany 48 - Using the AC+DC function

System-Related Operation 4 Using the Utility MenuU3606B User’s Guide 125Press [Shift] > [Utility] to enter the Utility menu. The first menu item al

Strany 49 - Measuring Current

4 System-Related Operation Utility Menu Summary126 U3606B User’s GuideUtility Menu SummaryThe Utility menu items are summarized in the table below. F

Strany 50 - Current measurement summary

System-Related Operation 4 Utility Menu SummaryU3606B User’s Guide 127SMothoF onSelect “oF” to disable the smooth function, or “on” to enable the smoo

Strany 51

4 System-Related Operation Utility Menu Summary128 U3606B User’s Guidedb.rEF NNNN ΩSet dB reference impedance value from 1 Ω to 9999 Ω.page 142SELF.t

Strany 52 - Measuring Resistance

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 129Utility Menu ItemsReading error messagesIf there are no errors in the error queue,

Strany 53 - U3606B User’s Guide 37

4 System-Related Operation Utility Menu Items130 U3606B User’s GuidePress [] again to read the remaining errors. The error queue is automatically cl

Strany 54 - 38 U3606B User’s Guide

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 131Recording measurement data (data logging)Press [] or [] to switch between “StoP”,

Strany 55 - Test ing Conti nuity

4 System-Related Operation Utility Menu Items132 U3606B User’s GuideEnabling refresh holdPress [] or [] to change the refresh hold variation (001% t

Strany 56 - Test current

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 133Setting the smooth functionThe smooth function is a special short- term average th

Strany 57 - Continuity test summary

U3606B User’s Guide XVList of TablesTable 1-1 Front panel descriptions 12Table 1-2 Rear panel descriptions 14Table 1-3 VFD display descriptio

Strany 58 - Measuring Low-Resistance

4 System-Related Operation Utility Menu Items134 U3606B User’s GuideTo set the fluctuation count, press [] until the cursor position is on the fluctu

Strany 59 - U3606B User’s Guide 43

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 135To set the number of points, press [] until the cursor position is on the number o

Strany 60

4 System-Related Operation Utility Menu Items136 U3606B User’s GuideConfiguring the scan signal parametersPress [Voltage] or [Current] if you wish t

Strany 61 - U3606B User’s Guide 45

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 137Press [] or [] to change the scan signal amplitude end position.Press [] or [] u

Strany 62 - 46 U3606B User’s Guide

4 System-Related Operation Utility Menu Items138 U3606B User’s GuideConfiguring the ramp signal parametersPress [Voltage] or [Current] if you wish t

Strany 63 - Measuring Capacitance

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 139Press [] or [] to change the ramp signal amplitude end position.Press [] or [] u

Strany 64 - 48 U3606B User’s Guide

4 System-Related Operation Utility Menu Items140 U3606B User’s GuideSetting the output protection stateThe OVP and OCP features depend on the output

Strany 65 - Measuring tips

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 141Press [] or [] to switch between “YES” and “no”. Select “YES” to enable the outpu

Strany 66 - Test ing Diodes

4 System-Related Operation Utility Menu Items142 U3606B User’s GuideSelecting a dBm reference resistance valueThe dBm function is logarithmic, and is

Strany 67 - U3606B User’s Guide 51

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 143Press [] or [] to select “YES” and then press [Shift] > [Save] to save. The in

Strany 68 - Testi ng ti ps

XVI U3606B User’s Guideof range) 165Table 5-4 Frequency sensitivity for voltage measurement 166Table 5-5 Frequency sensitivity for current mea

Strany 69 - Connect the test leads

4 System-Related Operation Utility Menu Items144 U3606B User’s GuideConfiguring the beeperNormally, the U3606B beeps whenever certain conditions are

Strany 70

System-Related Operation 4 Utility Menu ItemsU3606B User’s Guide 145Changing the power-on stateThe following procedure shows you how to enable or disa

Strany 71 - U3606B User’s Guide 55

4 System-Related Operation Utility Menu Items146 U3606B User’s GuideAdjusting the display brightnessPress [] or [] to cycle between the available br

Strany 72

System-Related Operation 4 Storing and Recalling Instrument StatesU3606B User’s Guide 147Storing and Recalling Instrument StatesYou can save and recal

Strany 73

4 System-Related Operation Storing and Recalling Instrument States148 U3606B User’s GuideStoring a stateTo store an instrument stateUse the arrow key

Strany 74 - 58 U3606B User’s Guide

System-Related Operation 4 Storing and Recalling Instrument StatesU3606B User’s Guide 149Recalling a stored stateTo recall an instrument stateUse the

Strany 75

4 System-Related Operation Remote Operation150 U3606B User’s GuideRemote OperationThe U3606B is shipped with both a GPIB (IEEE- 488) interface and a

Strany 76

System-Related Operation 4 Remote OperationU3606B User’s Guide 151Configuring and connecting the GPIB interfaceThe GPIB (IEEE- 488) connector on the r

Strany 77 - Setting the Resolution

4 System-Related Operation Remote Operation152 U3606B User’s GuideConfiguring and connecting the USB interfaceSelect the appropriate USB class for co

Strany 78 - Math Operations

System-Related Operation 4 Remote OperationU3606B User’s Guide 153SCPI language versionYou can determine the SCPI language version of the instrument b

Strany 79

1U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies1IntroductionAbout This Manual 2Documentation map 2Safety notes 2Preparing

Strany 80 - Enable the null function

4 System-Related Operation Remote Operation154 U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_EN.book Page 154 Frida

Strany 81 - Edit the null value

155U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies5Characteristics and SpecificationsProduct Characteristics 156Digital Multimete

Strany 82 - Enable the dBm function

5 Characteristics and Specifications Product Characteristics156 U3606B User’s GuideProduct CharacteristicsPOWER SUPPLY• Universal 100 Vac to 240 Vac

Strany 83 - Enable the dB function

Characteristics and Specifications 5 Product CharacteristicsU3606B User’s Guide 157WARRANTY• Please refer to http://www.agilent.com/go/warranty_terms•

Strany 84 - Edit the relative value

5 Characteristics and Specifications Digital Multimeter Specifications158 U3606B User’s GuideDigital Multimeter SpecificationsSpecification assumptio

Strany 85 - Enable the MinMax function

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 159DC specificationsTable 5 - 1 DC accuracy specifications ±

Strany 86 - *RST command)

5 Characteristics and Specifications Digital Multimeter Specifications160 U3606B User’s GuideResistance[4]100.000 Ω 1 mΩ 0.83 mA 0.04 + 0.008 0.04 +

Strany 87 - Enable the Limit function

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 161Capacitance[7]1.000 nF 0.001 nF0.75 µA current source- -

Strany 88 - 72 U3606B User’s Guide

5 Characteristics and Specifications Digital Multimeter Specifications162 U3606B User’s Guide[5] Specifications stated are for 4-wire low-resistance

Strany 89

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 163AC specificationsAC accuracy specificationsTable 5 - 2 AC

Strany 90 - Enable the Hold function

1 Introduction About This Manual2 U3606B User’s GuideAbout This ManualThe descriptions and instructions in this manual apply to the Agilent U3606B Mu

Strany 91 - Triggering the Multimeter

5 Characteristics and Specifications Digital Multimeter Specifications164 U3606B User’s Guide[8] For 750 V range: the accuracy is specified for input

Strany 92 - Front panel triggering

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 165Frequency specificationsTable 5 - 3 Frequency accuracy sp

Strany 93 - Remote interface triggering

5 Characteristics and Specifications Digital Multimeter Specifications166 U3606B User’s GuideTable 5 - 4 Frequency sensitivity for voltage measuremen

Strany 94

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 167Duty cycle and pulse width specificationsOperating specif

Strany 95 - DC Power Supply Operation

5 Characteristics and Specifications Digital Multimeter Specifications168 U3606B User’s GuideAC +DC current(1A at 1 kHz)Slow (5½ digit) 4 2.9 2.9Fast

Strany 96 - Constant Voltage Operation

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 169Supplemental characteristicsWARNINGExceeding the crest fa

Strany 97 - U3606B User’s Guide 81

5 Characteristics and Specifications Digital Multimeter Specifications170 U3606B User’s GuideInput protection: 750 Vrms on all rangesCrest factor: Fo

Strany 98

Characteristics and Specifications 5 Digital Multimeter SpecificationsU3606B User’s Guide 171ResistanceMeasurement method: Two-wire, open-circuit volt

Strany 99

5 Characteristics and Specifications Digital Multimeter Specifications172 U3606B User’s GuideCapacitanceMeasurement method: Computed from constant cu

Strany 100 - 84 U3606B User’s Guide

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 173DC Power Supply SpecificationsSafety considerationsThe U3606

Strany 101 - Enable the output

Introduction 1 Preparing the U3606BU3606B User’s Guide 3Preparing the U3606BCheck the shipmentWhen you receive your instrument, check the shipment acc

Strany 102 - Protection Functions

5 Characteristics and Specifications DC Power Supply Specifications174 U3606B User’s GuidePerformance specificationsTable 5 - 8 DC power supply perfo

Strany 103 - Select the OVP function

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 175Programming resolutionVoltage 1 mV 1 mV 1 mV 1 mV 0.1 mVCurr

Strany 104 - Checking the OVP operation

5 Characteristics and Specifications DC Power Supply Specifications176 U3606B User’s GuideSupplemental characteristicsTable 5 - 9 DC power supply sup

Strany 105 - Resetting the OVP condition

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 177Square-wave output characteristicsTable 5-10 Square-wave out

Strany 106 - Over-current protection (OCP)

5 Characteristics and Specifications DC Power Supply Specifications178 U3606B User’s Guide[2] For frequency signals greater than 100 Hz, an additiona

Strany 107 - Select the OCP function

Characteristics and Specifications 5 DC Power Supply SpecificationsU3606B User’s Guide 179Sweep characteristicsTable 5-11 Scan output characteristicsS

Strany 108 - Checking the OCP operation

5 Characteristics and Specifications DC Power Supply Specifications180 U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_

Strany 109 - Resetting the OCP condition

181U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies6List of Error MessagesError Messages 182Command errors 183Execution errors

Strany 110 - Over-voltage limit (OV)

6 List of Error Messages Error Messages182 U3606B User’s GuideError MessagesError messages are created once an erroneous condition is detected.Errors

Strany 111 - Select the OV function

List of Error Messages 6 Error MessagesU3606B User’s Guide 183Command errorsThe following table shows the list of command errors. These errors set the

Strany 112

II U3606B User’s GuideNotices© Agilent Technologies, Inc. 2013–2014No part of this manual may be reproduced in any form or by any means (including ele

Strany 113 - Over-current limit (OC)

1 Introduction Preparing the U3606B4 U3606B User’s GuidePower cordU8201A combo test lead kitUSB Standard-A to Type-B interface cableCertificate of Ca

Strany 114 - Select the OC function

6 List of Error Messages Error Messages184 U3606B User’s GuideExecution errorsThe following table shows the list of execution errors. These errors se

Strany 115

List of Error Messages 6 Error MessagesU3606B User’s Guide 185Internal errorsThe following table shows the list of internal errors.Query errorsThe fol

Strany 116 - Square-Wave Operation

6 List of Error Messages Error Messages186 U3606B User’s GuideSelf-test errorsThe following errors indicate failures that may occur during a self- te

Strany 117 - U3606B User’s Guide 101

List of Error Messages 6 Error MessagesU3606B User’s Guide 187Calibration errorsThe following errors indicate failures that may occur during a calibra

Strany 118

6 List of Error Messages Error Messages188 U3606B User’s Guide723 Cal CAP offset out of range726 Cal RES open out of range742 Cal checksum failed, DC

Strany 119 - U3606B User’s Guide 103

© Agilent Technologies, Inc. 2013–2014Second Edition, July 3, 2014U3606-90054www.agilent.comAgilent TechnologiesContact usTo obtain service, warranty,

Strany 120

Introduction 1 Preparing the U3606BU3606B User’s Guide 5Connect power to the instrumentNOTEThe U3606B is shipped from the factory with a power-line co

Strany 121

1 Introduction Preparing the U3606B6 U3606B User’s GuideNOTE• For subsequent power cycles, the U3606B returns to the last power-off state by default.

Strany 122 - Sweep Functions

Introduction 1 Preparing the U3606BU3606B User’s Guide 7Adjust the carry handle12a32bU3606-90054_UG_EN.book Page 7 Friday, July 11, 2014 5:12 PM

Strany 123 - Connect the load

1 Introduction Preparing the U3606B8 U3606B User’s GuideRack mount the instrumentYou can mount the U3606B in a standard 19- inch rack cabinet using o

Strany 124 - 108 U3606B User’s Guide

Introduction 1 Preparing the U3606BU3606B User’s Guide 9Figure 1-3 Rack mount dimensionsU3606-90054_UG_EN.book Page 9 Friday, July 11, 2014 5:12 PM

Strany 125 - Scan signal

1 Introduction Preparing the U3606B10 U3606B User’s GuideStack multiple U3606B unitsYou may stack multiple U3606B units on top of each other. The rub

Strany 126

Introduction 1 The U3606B in BriefU3606B User’s Guide 11The U3606B in BriefDimensionsFigure 1-4 U3606B dimensions105 mm334 mm226 mmU3606-90054_UG_EN.b

Strany 127 - U3606B User’s Guide 111

1 Introduction The U3606B in Brief12 U3606B User’s GuideOverviewFront panelThe front panel parts of the U3606B are described in this section.Figure 1

Strany 128

Introduction 1 The U3606B in BriefU3606B User’s Guide 13Rear panelThe rear panel parts of the U3606B are described in this section.Figure 1-6 The rear

Strany 129 - Selecting a Range

U3606B User’s Guide IIISafety SymbolsThe following symbols on the instrument and in the documentation indicate precautions which must be taken to main

Strany 130 - Enabling the Output

1 Introduction The U3606B in Brief14 U3606B User’s GuideTable 1 - 2 Rear panel descriptionsLegend Description1 AC inlet Connects the AC power line —

Strany 131 - Remote Sensing

Introduction 1 The U3606B in BriefU3606B User’s Guide 15Display screenThe display annunciators of the U3606B are described in this section.Figure 1-7

Strany 132 - +S + + – – –S

1 Introduction The U3606B in Brief16 U3606B User’s Guide2EXT Remote sensing operation enabledCC Constant current operation selectedCV Constant voltag

Strany 133

Introduction 1 The U3606B in BriefU3606B User’s Guide 176LOG Data logging in progressStore Store instrument state selectedRecall Recall instrument sta

Strany 134

1 Introduction The U3606B in Brief18 U3606B User’s GuideKeypadFigure 1-8 The keypad at a glance11ms Pulse width unit for square-wave output% Duty cyc

Strany 135 - U3606B User’s Guide 119

Introduction 1 The U3606B in BriefU3606B User’s Guide 19Using the Shift keyTo select a Shift function: first, press [Shift] (the Shift annunciator wil

Strany 136 - Enable remote sensing

1 Introduction The U3606B in Brief20 U3606B User’s Guide• Press [Shift] to select a shift function.• Press [Local] to unlock the front-panel keys whe

Strany 137 - Output rating

Introduction 1 The U3606B in BriefU3606B User’s Guide 21• Press [] to select the resistance (2-wire) measurement function.• Press [] again to select t

Strany 138 - Output noise

1 Introduction The U3606B in Brief22 U3606B User’s Guide• Press [] to select a higher range and disable autoranging.• Press [] to select a lower rang

Strany 139 - System-Related Operation

Introduction 1 The U3606B in BriefU3606B User’s Guide 23 Press [Shift] > [Limit] to set the over-current limit value for the CV output or the over-

Strany 140 - Using the Utility Menu

IV U3606B User’s GuideSafety ConsiderationsRead the information below before using this instrument. The following general safety precautions must be o

Strany 141 - U3606B User’s Guide 125

1 Introduction The U3606B in Brief24 U3606B User’s GuideInput/Output terminalsFigure 1-9 The input/output terminals at a glanceWARNINGBefore attempti

Strany 142 - Utility Menu Summary

Introduction 1 The U3606B in BriefU3606B User’s Guide 25Table 1 - 5 Input terminal connections Function Input terminals (+ SENSE –) Input protectionDC

Strany 143 - U3606B User’s Guide 127

1 Introduction The U3606B in Brief26 U3606B User’s GuideTable 1 - 6 Output terminal connections Function Output terminals (+ FORCE –) Maximum outputC

Strany 144 - 128 U3606B User’s Guide

Introduction 1 The U3606B in BriefU3606B User’s Guide 27Square-wave output• Amplitude: 0 V to 30 V[1]• Frequency: Multiple predefined values[3]• Duty

Strany 145 - Utility Menu Items

1 Introduction The U3606B in Brief28 U3606B User’s GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.U3606-90054_UG_EN.book Page 28 Friday, July 11,

Strany 146

29U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies2Operation and FeaturesMeasuring Voltage 30Measuring Current 33Measuring Resi

Strany 147

2 Operation and Features Measuring Voltage30 U3606B User’s GuideMeasuring VoltageConnect the test leadsSelect the voltage measurement function124Pres

Strany 148 - Enabling refresh hold

Operation and Features 2 Measuring VoltageU3606B User’s Guide 31Voltage measurement summaryProbe the test points and read the displayIn this example,

Strany 149 - Setting the smooth function

2 Operation and Features Measuring Voltage32 U3606B User’s GuideAC voltage measurementAvailable ranges 100.000 mV, 1.00000 V, 10.0000 V, 100.000 V, 7

Strany 150

Operation and Features 2 Measuring CurrentU3606B User’s Guide 33Measuring CurrentConnect the test leadsSelect the current measurement function124Press

Strany 151

U3606B User’s Guide VEnvironmental ConditionsThis instrument is designed for indoor use and in an area with low condensation. The table below shows th

Strany 152

2 Operation and Features Measuring Current34 U3606B User’s GuideCurrent measurement summaryProbe the test points and read the displayIn this example,

Strany 153

Operation and Features 2 Measuring CurrentU3606B User’s Guide 35AC current measurementAvailable ranges 10.0000 mA, 100.000 mA, 1.00000 A, 3.0000 AMeas

Strany 154

2 Operation and Features Measuring Resistance36 U3606B User’s GuideMeasuring ResistanceConnect the test leadsSelect the resistance measurement functi

Strany 155 - Number of

Operation and Features 2 Measuring ResistanceU3606B User’s Guide 37Probe the test points and read the displayIn this example, we obtain a resistance m

Strany 156

2 Operation and Features Measuring Resistance38 U3606B User’s GuideResistance measurement summaryTable 2 - 3 Resistance measurement summary Item Desc

Strany 157

Operation and Features 2 Testing ContinuityU3606B User’s Guide 39Test ing Conti nuityConnect the test leadsSelect the continuity test function124Press

Strany 158 - Performing a self-test

2 Operation and Features Testing Continuity40 U3606B User’s GuideProbe the test points and read the displayIn this example, a short is detected in th

Strany 159

Operation and Features 2 Testing ContinuityU3606B User’s Guide 41Continuity test summaryTable 2 - 4 Continuity test summary Item DescriptionMeasuremen

Strany 160 - Configuring the beeper

2 Operation and Features Measuring Low-Resistance42 U3606B User’s GuideMeasuring Low-ResistanceConnect the test leads1234U3606-90054_UG_EN.book Page

Strany 161 - Changing the power-on state

Operation and Features 2 Measuring Low-ResistanceU3606B User’s Guide 43Select the low-resistance measurement functionProbe the test points and read th

Strany 162

VI U3606B User’s GuideRegulatory MarkingsThe CE mark is a registered trademarkof the European Community. This CEmark shows that the product complieswi

Strany 163

2 Operation and Features Measuring Low-Resistance44 U3606B User’s GuideLow-resistance measurement summaryCAUTIONDisconnect circuit power and discharg

Strany 164 - Storing a state

Operation and Features 2 Measuring Low-ResistanceU3606B User’s Guide 45Table 2 - 6 Low-resistance test current values[1][1] When the display shows “OL

Strany 165 - Recalling a stored state

2 Operation and Features Measuring Low-Resistance46 U3606B User’s GuideChanging the low-resistance test currentUse the arrow keys to navigate the edi

Strany 166 - Remote Operation

Operation and Features 2 Measuring CapacitanceU3606B User’s Guide 47Measuring CapacitanceConnect the test leadsSelect the capacitance measurement func

Strany 167 - GPIB address

2 Operation and Features Measuring Capacitance48 U3606B User’s GuideProbe the test points and read the displayIn this example, we obtain a capacitanc

Strany 168 - SCPI commands

Operation and Features 2 Measuring CapacitanceU3606B User’s Guide 49Capacitance measurement summaryNOTEMeasuring tips• The U3606B calculates capacitan

Strany 169 - SCPI query time-out

2 Operation and Features Testing Diodes50 U3606B User’s GuideTest ing DiodesConnect the test leadsSelect the diode test function124Press [] to switch

Strany 170 - 154 U3606B User’s Guide

Operation and Features 2 Testing DiodesU3606B User’s Guide 51Probe the test points and read the displayIn this example, we obtain an open result from

Strany 171 - Agilent Technologies

2 Operation and Features Testing Diodes52 U3606B User’s GuideDiode test summaryCAUTIONDisconnect circuit power and discharge all high-voltage capacit

Strany 172 - Product Characteristics

Operation and Features 2 Measuring Frequency/Pulse Width/Duty Cycle (Voltage Path)U3606B User’s Guide 53Measuring Frequency/Pulse Width/Duty Cycle (Vo

Strany 173 - U3606B User’s Guide 157

U3606B User’s Guide VIIWaste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ECThis instrument complies with the WEEE Directive (2002/96/

Strany 174 - Specification assumptions

2 Operation and Features Measuring Frequency/Pulse Width/Duty Cycle (Voltage Path)54 U3606B User’s GuideProbe the test points and read the displayIn

Strany 175 - DC specifications

Operation and Features 2 Measuring Frequency/Pulse Width/Duty Cycle (Voltage Path)U3606B User’s Guide 55Frequency/pulse width/duty cycle measurement (

Strany 176 - 160 U3606B User’s Guide

2 Operation and Features Measuring Frequency/Pulse Width/Duty Cycle (Current Path)56 U3606B User’s GuideMeasuring Frequency/Pulse Width/Duty Cycle (C

Strany 177 - U3606B User’s Guide 161

Operation and Features 2 Measuring Frequency/Pulse Width/Duty Cycle (Current Path)U3606B User’s Guide 57Probe the test points and read the displayIn t

Strany 178

2 Operation and Features Measuring Frequency/Pulse Width/Duty Cycle (Current Path)58 U3606B User’s GuideFrequency/pulse width/duty cycle measurement

Strany 179 - AC specifications

Operation and Features 2 Selecting a RangeU3606B User’s Guide 59Selecting a RangeYou can allow the U3606B to automatically select the range using auto

Strany 180

2 Operation and Features Selecting a Range60 U3606B User’s GuideNOTE• Autoranging is selected at default factory power-on and after a remote reset.•

Strany 181 - Frequency specifications

Operation and Features 2 Setting the ResolutionU3606B User’s Guide 61Setting the ResolutionYou can select either 4½ digit or 5½ digit resolution for t

Strany 182 - 166 U3606B User’s Guide

2 Operation and Features Math Operations62 U3606B User’s GuideMath OperationsThe U3606B provides six math operations: null measurements, dB measureme

Strany 183 - Operating specifications

Operation and Features 2 Math OperationsU3606B User’s Guide 63NullWhen making null measurements, also called relative, each reading is the difference

Strany 184 - (continued)

VIII U3606B User’s GuideDeclaration of Conformity (DoC)The Declaration of Conformity (DoC) for this instrument is available on the Agilent website. Yo

Strany 185 - Supplemental characteristics

2 Operation and Features Math Operations64 U3606B User’s GuideEnable the null functionTo disable the null functionU3606-90054_UG_EN.book Page 64 Fr

Strany 186 - 170 U3606B User’s Guide

Operation and Features 2 Math OperationsU3606B User’s Guide 65Edit the null valueUse the arrow keys to navigate the edit mode.12• Press [] or [] to se

Strany 187 - U3606B User’s Guide 171

2 Operation and Features Math Operations66 U3606B User’s GuidedBm measurementsThe logarithmic dBm (decibels relative to 1 mW) scale is often used in

Strany 188 - 172 U3606B User’s Guide

Operation and Features 2 Math OperationsU3606B User’s Guide 67dB measurementsEach dB measurement is the difference between the input signal and a stor

Strany 189 - Specifications assumptions

2 Operation and Features Math Operations68 U3606B User’s GuideEdit the relative valueUse the arrow keys to navigate the edit mode.12• Press [] or []

Strany 190 - Performance specifications

Operation and Features 2 Math OperationsU3606B User’s Guide 69MinMaxThe MinMax operation stores the minimum and maximum values, the average, and the n

Strany 191 - U3606B User’s Guide 175

2 Operation and Features Math Operations70 U3606B User’s GuideLimitThe limit test function enables you to perform pass or fail testing to the upper a

Strany 192

Operation and Features 2 Math OperationsU3606B User’s Guide 71Enable the Limit function• PASS: Readings are within the specified limits. • HI: Reading

Strany 193 - U3606B User’s Guide 177

2 Operation and Features Math Operations72 U3606B User’s GuideEdit the upper and lower limit valuesUse the arrow keys to navigate the edit mode.Save

Strany 194

Operation and Features 2 Math OperationsU3606B User’s Guide 73HoldThe refresh hold feature allows you to capture and hold a reading, within the specif

Strany 195 - Sweep characteristics

U3606B User’s Guide IXTable of Contents1 IntroductionAbout This Manual 2Documentation map 2Safety notes 2Preparing the U3606B 3Che

Strany 196 - 180 U3606B User’s Guide

2 Operation and Features Math Operations74 U3606B User’s GuideEnable the Hold functionTo disable the Hold functionU3606-90054_UG_EN.book Page 74 Fr

Strany 197 - List of Error Messages

Operation and Features 2 Triggering the MultimeterU3606B User’s Guide 75Triggering the MultimeterThe U3606B triggering system allows you to generate t

Strany 198 - Error Messages

2 Operation and Features Triggering the Multimeter76 U3606B User’s GuideFront panel triggeringSingle triggeringThe U3606B takes one reading each time

Strany 199 - Command errors

Operation and Features 2 Triggering the MultimeterU3606B User’s Guide 77Remote interface triggeringImmediate triggeringIn the immediate trigger mode,

Strany 200 - Execution errors

2 Operation and Features Triggering the Multimeter78 U3606B User’s GuideRemote interface operation:• The TRIGger:SOURce BUS command selects the bus

Strany 201 - Device specific errors

79U3606B Multimeter|DC Power SupplyUser’s GuideAgilent Technologies3DC Power Supply OperationConstant Voltage Operation 80Constant Current Operatio

Strany 202 - Self-test errors

3 DC Power Supply Operation Constant Voltage Operation80 U3606B User’s GuideConstant Voltage OperationConnect the load1LOAD32U3606-90054_UG_EN.book

Strany 203 - Calibration errors

DC Power Supply Operation 3 Constant Voltage OperationU3606B User’s Guide 81Select the constant voltage functionAdjust the constant voltage value5LOAD

Strany 204 - 188 U3606B User’s Guide

3 DC Power Supply Operation Constant Voltage Operation82 U3606B User’s GuideEnable the output8NOTE• The output voltage is limited by the range select

Strany 205

DC Power Supply Operation 3 Constant Current OperationU3606B User’s Guide 83Constant Current OperationConnect the load1LOAD32U3606-90054_UG_EN.book P

Komentáře k této Příručce

Žádné komentáře