Agilent 87050E50 Ohm Multiport Test SetsData Sheet This document describes the performance and fea-tures of Agilent Technologies 87050E 50 ohm multi-p
10 Specification Supplemental information System bandwidth Network analyzer Fine Fine Med Wide Wide 15 Hz 15 Hz 4000 Hz 6500 Hz Receiver dy
11Network analyzer Specification Characteristic (dBm) Output power (system maximum) <1 GHz >1 GHz8712ET, no attenuator — 10.5 78712E
12Test set input/output performanceParameter Specification Supplemental Frequency range 3 MHz to 2.2 GHz — RF input powerMaximum input power —
13Description Specification Supplemental information Front panel ports87050E, Option 004 4 Type-N, female 50Ω (nominal)87050E, Option 008 8
14Physical dimensionsPhysical dimensions of the Agilent 87050E Option 004multiport test set1Physical dimensions of the Agilent 87050E Option 008 multi
15Block diagramsBlock diagram for the Agilent 87050E (only one test set port pair is shown)REAR PANELExternal DetectorsInput B*Input BYAUX InputInput
16Test set controlControl of the switches inside the test set and cali-bration of the test system can be accomplished from the front panel of the netw
17Disk driveTrace data, instrument states (including calibra-tion data), and IBASIC programs can be saved on floppy disks using the built-in 3.5 inch
18NFSThe analyzer’s built-in NFS (network file system) client provides access to remote files and directo-ries using the LAN. With NFS, remote files a
19Other calibrations Besides using a Test Set Cal, individual instrument states and their corresponding calibrations can be saved and recalled for use
2All specifications and characteristics apply over a 25 °C ± 5 °C range (unless otherwise stated) and 30 minutes after the instrument has been turned
Java is a U.S. trademark of Sun Microsystems, Inc.Microsoft, MS-DOS, Windows, Windows 95, Windows 98, Windows NT, Word 97, and Excel 97 are U.S. reg
3Agilent 85032B/E Type-N calibration kit Specification1 (dB) Typical2 (dB) Parameter 3 MHz 1.3 GHz 2.2 GHz to 1.3 GHz to 2.2 GHz to 3 GHzDir
4System performance Two-port calibration (user) Specification1 (dB) Typical2 (dB) Parameter 3 MHz 1.3 GHz 2.2 GHz to 1.3 GHz to 2.2 GHz to 3
5Agilent 85032B/E Type-N calibration kit1. These specifications and supplementals are valid for reflection (one-port) and transmission (enhanced-resp
6System performance Transmission/reflection (T/R) calibration (user)1. These uncertainty curves only include the effects of the test port(s) within t
7Agilent 85032B/E Type-N calibration kit 1. These uncertainty curves only include the effects of the test port(s) within the measurement path. The ef
8Type-N Specification1 ( dB) Typical (dB)Parameter 3 MHz 1.3 GHz 3 MHz 1.3 GHz 2.2 GHz to 1.3 GHz to 2.2 GHz to 1.3 GHz to 2.2 GHz
9 Specification Typical System bandwidth Fine Fine Med Wide Wide 15 Hz 15 Hz 4000 Hz 6500 HzNetwork analyzer 3 MHz 1.3 GHz