
Safety Summary
The following general safety precautions must be observed during all phases of
operation, service, and repair of this instrument. Failure to comply with these
precautions or with specific warnings elsewhere in this manual may impair the
protections provided by the equipment. In addition, it violates safety standards of
design, manufacture, and intended use of the instrument. Agilent Technologies, Inc.
assumes no liability for customer’s failure to comply with these requirements.
NOTE Agilent B1500 complies with INSTALLATION CATEGORY II for mains input and
INSTALLATION CATEGORY I for measurement input terminals, and POLLUTION
DEGREE 2 defined in IEC 1010-1.
Agilent B1500 is an INDOOR USE product.
NOTE LED in Agilent B1500 is Class 1 in accordance with IEC 825-1. CLASS 1 LED PRODUCT.
• GROUND THE INSTRUMENT
This is Safety Class I instrument. To minimize shock hazard, the instrument chassis
and cabin
et must be connected to an electrical ground. The power terminal and the
power cable must meet International Electrotechnical Commission (IEC) safety
standards.
• DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not
operate the instrument in the presence of flammable gases or fumes.
Operation of
any electrical instrument in such an environment constitutes a
definite safety hazard.
• KEEP AWAY FROM LIVE CIRCUITS
Operation p
ersonnel must not remove instrument covers. Component replacement
and internal
adjustments must be made by qualified maintenance personnel. Do
not replace components with power cable connected. Under certain conditions,
dangerous voltages may exist even with the power cable removed. To avoid
injuries, always disconnect power and discharge circuits before touching them.
• DO NOT SERVICE OR ADJUST ALONE
Do not atte
mpt internal service or adjustment unless another person, capable of
renderin
g first aid and resuscitation, is present.
Komentáře k této Příručce