2-84 Fully Coded 3GPP W-CDMA Personality User’s and Programming Guide
Using Functions ESG Family Signal Generators
3GPP W-CDMA Base Station Performance Testing Option 200
Example Test Procedure
Follow this example procedure to perform a 3GPP W-CDMA reference sensitivity level test
on your BS. Perform the procedures in the subsections sequentially, in the order in which
they appear in this document.
Subsection 1. Equipment Setup and Preliminary BER Verification
Complete the following steps to connect the equipment and perform a BER verification test
on your BS.
Figure 2-16 Reference Sensitivity Level Equipment Setup
1. Connect the BS to the test system as shown in Figure 2-16.
a. Using the appropriate cables, adapters, and antennae, connect the output of the ESG
to the RF input of the BS.
b. If the BS has multiple input ports, terminate the unused ports.
c. Connect the system controller and the BER test platform to the BS.
2. Measure the Bit Error Ratio (BER) of the BS.
The controller or BER test platform measures the bit error ratio of the BS exposed to
the RF output power specified by TS 25.141.7.8 V3.4. This process verifies that the BER
of the BS is within specification before decreasing the amplitude of the RF output
power.
3. Record the first BER measurement result in the column titled, “Verification BER Value”
in Table 2-44.
4. Compare the measured BER value in the column titled, “Verification BER Value” with
the limits from the column titled, “Specification Limitations.”
• If the measured value is within the limits, continue to subsection 2.