2-70 Fully Coded 3GPP W-CDMA Personality User’s and Programming Guide
Using Functions ESG Family Signal Generators
3GPP W-CDMA User Equipment Performance Tests Option 200
At this point, the controller must configure the UE into a test mode. With the UE
operating in test mode, the controller assigns the UE a dedicated physical channel on
which to receive and demodulate the transmitted data.
3. Measure the Bit Error Ratio (BER) of the data received by the UE on RMC 12.2 kbps
(25.101 V3.3).
The controller (or BER test platform) is measuring the bit error ratio of the UE exposed
to Î
or
(the RF output of ESG 1) only. This process verifies that the BER of the UE is
within specification prior to the introduction of the frequency-related interferers.
4. In Table 2-40, record the measured BER value in the column titled, “Verification BER
Value.”
5. Compare the measured BER value in the column titled, “Verification BER Value” with
the limits from the column titled, “Specification Limitations.”
If the measured value is within the limits, continue to subsection 2.
If the measured value is outside the limits, determine the cause of failure and repair
the UE. After repair, return to Step 1 of this subsection.
Subsection 2. Negative Frequency Offset Interferers IRR Measurements
Complete the following steps to make negative frequency offset measurements on your UE.
Figure 2-13 IRR Measurements Equipment Setup